China

DUORUI DR-700-HCN Hydrogen Cyanide Gas Detector, Standard, Range: 0-50PPM

DUORUI Hydrogen Cyanide Gas Detector DR-700-HCN is an online fixed Gas Detector, detecting the concentration of hydrogen cyanide gas is 0-50PPM, DR-700-HCN Gas Detector can continuously detect online for 24 hours, Power is 2.5W.

DuoRui DR-700-HCN (Standard) Gas DetectorSPEC

DuoRui DR-700-HCN (Standard) Gas DetectorDetails

DuoRui DR-700-HCN (Standard) Gas DetectorPacking list

SKU
NB023861
Sensors principle
Electrochemistry
Detect gas
Hydrogen cyanide HCN
Sampling method
diffusion
Range
0~50ppm
Humidity
<95%RH
service life
1 to 2 years (determined by Sensors)
display error
±5%FS
Cable Specifications
Tier 3 or Tier 4
Explosion-proof sign
Exd II CT6
Shell material
die casting aluminum
Working Power
2.5W
Power Supply
24VDC
Response time
T90≤60s
operating temperature
-20~50℃
Operating Time
24H online work
Electrical interface
M20 * 1.5 internal thread
transmission distance
≤1200m
Output signal
4~ 20mA or RS485
Protection level
IP65
Display
digital display
Alarm mode
No alarm/sound and light alarm
Installation method
Fixed bracket, wall mounted
DR-700-HCN (Standard)
Gas Detector
DUORUI DR-700-HCN Hydrogen Cyanide Gas Detector, Standard, Range: 0-50PPM Picture

Introduction

DR-700,Using imported sensors, it can detect flammable/toxic gases, a total of four styles, according to the different characteristics of the gas, the Detector is equipped with different gas sensor components, which are used to detect the corresponding gas concentration in the surrounding atmosphere. The Detector can be selected with or without a display and audible and visual alarm. It can be installed in hazardous areas and non-hazardous areas in Class II explosion-proof environments.