JINGQI DR-16 multifunctional numerical control digestion instrument 16 holes

JINGQI DR-16 multifunctional numerical control digestion instrument digestion temperature room temperature~ 180 ℃, automatic thermostatic control, temperature control accuracy +/- 0.5 ℃, digestion time 1~ 999min, single digestion sample number 16, power supply AC220V, power consumption maximum 400W
Model:

JingQi DR-16 Multifunctional numerical control digestion instrumentSPEC

JingQi DR-16 Multifunctional numerical control digestion instrumentDetails

JingQi DR-16 Multifunctional numerical control digestion instrumentPacking list

SKU
NB024085
Temperature range
RT+~180℃
Temperature control Accuracy
±0.5℃
digestion time
1~999min
Number of samples per digestion
16.
Power supply Voltage
AC220V
power consumption
≤400W
Dimension
230*310*140mm
Weight
About 4.5Kg
COD Measurement Range
5-2000Mg/L (COD measurement with 3cm Colorimetric tank spectrophotometer or titration device)
DR-16
Multifunctional numerical control digestion instrument
JINGQI DR-16 multifunctional numerical control digestion instrument 16 holes Picture

Instrument Introduction

This instrument can realize the chemical analysis and digestion function of COD, total phosphorus, total nitrogen and total chromium of various water samples that require heating process. Can be placed 16 at the same timeA φ16mm reaction tube can automatically control the temperature according to the set digestion temperature and digestion time.

Features

1. The heating speed is fast, and it only takes 15min to rise to the set temperature.

2. High temperature control accuracy.

3. It has multi-point error-free calibration to achieve zero error measurement of set points, and completely eliminates the error caused by the nonlinearity of temperature sensors in common digesters on the market.

4. Effective thermal insulation measures are adopted to reduce energy consumption.

5. Have regular reminders

6. The instrument has the function of secondary protection, when the temperature of the digestion instrument exceeds 185 degrees, the instrument will cut off the power supply by itself to ensure the safety of the digestion process

7. The standard digestion tube is made of imported glass, which has the characteristics of no burst in the state of quenching and heating