Unitec NBC2000-NO(P)/2000ppm Nitric oxide Gas Detector Specifications

Search
UNITEC NBC2000-NO (P) Nitric oxide Gas Detector Range: 0~2000ppm

Brand:Unitec

Model:NBC2000-NO(P)/2000ppm

Name:Nitric oxide Gas Detector

DetailsContact
Specifications
Detect gas Nitric oxide NO
Sensors principle electrochemistry
Sampling method Pump suction
Range 0~2000ppm
resolution 0.1ppm
detection Accuracy ±2% F.S.
Interface USB
Response time ≤10s
Repeatability ≤±1%
Linearity ≤±1%
Zero drift ≤ +/- 1% (F. S/year)
Display LCD dot matrix display technology
Operating language Support Chinese and English
Display unit Multiple Gas Unit switch display
Operating temperature -40~70℃
Environmental humidity 0~95%RH
Explosion-proof sign Exia ⅡCT4
Protection level IP66
Alarm mode Sound, light, vibration
Operating Time 100H (turn off the pump)
Dimension 205*75*32mm
Weight 300g
Packing list
machine X1, manual X1, certificate X1, warranty card X1
After-sales instructions

Warranty days: 365 days

[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/24344/Specification.html , which is only used by users who purchase commodities from the NBCHAO.