LS201 digital glass thickness meter uses the principle of optical reflection to measure the thickness of glass on one side of the glass, especially suitable for measuring occasions where general measuring tools such as scales or vernier calipers cannot or are not easy to operate, such as the thickness of architectural laminated glass and insulating glass windows Measurement. For the measurement of air laminated glass, the thickness of multiple layers of glass and the intermediate air layer can also be obtained at the same time. The instrument adopts CCD detection, liquid crystal display, simple operation, fast and reliable measurement.
1. Chinese and English display modes can be switched, and the use has no borders.
2. Non-destructive testing of glass thickness, laser reflection principle, measuring glass thickness on one side of the glass.
3. Fast measurement, the accuracy can reach 0.1mm.
4. It can measure various glass materials such as three-glass two-cavity, laminated glass, etc.

5. There are two modes of automatic measurement and manual measurement, which can accurately test the thickness of insulating glass of various specifications.

6. Measure in manual mode, set the corresponding parameters according to the actual type of glass, and you can get accurate data.

1. Keep the surface of the glass to be tested clean to improve the measurement accuracy.
2. Try to avoid overlapping multiple pieces of glass for testing, which may cause wrong test results.
3. Keep the Detector on the back of the instrument clean. It can be wiped with a soft cloth or cotton swab dampened with alcohol, and not with a cloth dampened with other organic solvents.
4. In order to improve the measurement accuracy, try to avoid testing the back of the instrument directly against the sunlight.
5. Avoid looking directly at the laser.
6. Avoid contact with corrosive items and keep away from high temperature and high humidity environment.
7. When the battery symbol is empty and flashing, please replace the battery in time.