HUIRUIPU HRP-T1000-CO Carbon Monoxide Gas Detector (No display with light)

SE
Sensors principle of HUIRUIPU HRP-T1000-CO carbon monoxide Gas Detector Electrochemistry type, detection of gas CO, sampling method Natural diffusion, debugging method Infrared remote control, environment temperature -20 ℃~ 50 ℃, Relative Humidity < 95%, explosion-proof method Explosion-proof type, explosion-proof grade Ex d Ⅱ C T6 Gb.
$156.00/set
PromotionLoading...
Coupon
Certificate

HuiRuiPu HRP-T1000-CO Carbon monoxide Gas Detector (no light model shown)SPEC

HuiRuiPu HRP-T1000-CO Carbon monoxide Gas Detector (no light model shown)Details

HuiRuiPu HRP-T1000-CO Carbon monoxide Gas Detector (no light model shown)Packing list

SKU
NB026450
Sensors principle
electrochemistry
Detection gas
CO
Sampling method
diffusion
Debugging method
Infrared remote control
Environment temperature
-20~+50℃
Relative Humidity
<95%
Explosion-proof method
flameproof
Explosion-proof sign
Ex dⅡC T6 Gb
Power
DC24V±15%
output signal
Current: (4~ 20) mA
switching quantity
1 (the first-level alarm point is always open)
power consumption
≤3W
Connection Cable
≥1.5mm2×3;≥1.5mm2×4
Maximum distance between Detector and host
≤1000m
Total Weight
≤1500g
Operating Pressure
86 ~ 106kPa
Dimensions
190*150*95mm
range
0~1000ppm
HRP-T1000-CO
Carbon monoxide Gas Detector (no light model shown)
HUIRUIPU HRP-T1000-CO Carbon Monoxide Gas Detector (No display with light) Picture

Introduction

HRP-T1000 Gas Detector is used in flammable and explosive gas leakage places and chemical plant areas where poisonous and harmful exists. The instrument adopts catalytic combustion sensor and electrochemical sensor technology imported from the United States. The product has the advantages of stable signal and high precision. The instrument shell is made of The explosion-proof and explosion-proof design of cast aluminum is one-time forming, and the wiring method is suitable for various dangerous places.

The instrument is widely used in pharmaceuticals, chemical fertilizers, natural gas pipeline networks, sewage treatment, municipal administration, iron and steel smelting, chlorine plants, acetylene plants, refrigeration workshops, chemical workshops, gas station areas, boiler rooms, hotel kitchen operating rooms, etc. that require anti-virus and fire protection Explosion-proof places.

Features

◆The detection accuracy and measuring range are adjustable

◆Long life, high sensitivity, low drift, stable and reliable work

◆Two-level concentration alarm, with relay output function

◆With temperature compensation, automatic zero point correction function

◆4~20mA standard analog output and RS485 digital output, can be uploaded to DCS, PLC system

◆Infrared remote control mode, the Detector can be adjusted without opening the cover, which is safe and convenient

◆Explosion-proof design is suitable for hazardous conditions in zones 1 and 2


Detection principle : The system provides 24V standard DC Voltage to the external transmitter, collects
                     the input signal of the standard 4-20mA transmitter, analyzes and processes it to complete the digital display and alarm operation.

Applicable objects : This system supports the input signals of various standard transmitters. Such as gas transmitters: carbon monoxide, hydrogen sulfide,

Gas alarm controller use and Application

It can be used in oil exploration, oil and gas transportation, oil refining, metallurgy, power plants, chemicals, oil depots, liquefied gas stations, mines, tunnels, tunnels, underground pipelines and other places that require fire protection, explosion protection, and poisoning for gas safety detection and alarm.


FAQ
QCan all carbon monoxide gas detectors be used for detection in the GB3836.1 standard?
A Not necessarily, but this HRP-T1000-CO carbon monoxide gas detector could be considered.
QHRP-T1000-CO carbon monoxide gas detector (no display with lamp) Sensors principle is electrochemistry?
A Yes, this model Gas detector uses the detection principle of electrochemistry. Detect gas CO
Knowledge