China

HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (No Lights, LCD Model)

SE
Sensors principle of HUIRUIPU HRP-T1000-NH3 ammonia Gas Detector electrochemistry, detection of gas NH3, sampling method natural diffusion, Display mode LCD liquid crystal display concentration value, status indication 3 LED lights indicate power supply, secondary alarm, debugging infrared remote control.
$215.00/set
PromotionLoading...
Coupon
Certificate

HuiRuiPu HRP-T1000-NH3 Ammonia Gas Detector (No Lights, LCD Model)SPEC

HuiRuiPu HRP-T1000-NH3 Ammonia Gas Detector (No Lights, LCD Model)Details

HuiRuiPu HRP-T1000-NH3 Ammonia Gas Detector (No Lights, LCD Model)Packing list

SKU
NB026464
Sensors principle
Electrochemistry
Detect gas
Ammonia NH3
Sampling method
Diffusion
Display
LCD liquid crystal display concentration value
status indication
3 LED lights indicating Power , secondary alarm
debugging method
Infrared remote control
Ambient Temperature
-20~+50℃
Relative Humidity
<95%
Explosion-proof method
flameproof type
Explosion-proof sign
Ex dⅡC T6 Gb
Power
DC24V±15%
Output signal
Current: (4~ 20) mA
switching quantity
1 (the first-level alarm point is normally open)
power consumption
≤3W
Connection Cable
≥1.5mm2×3;≥1.5mm2×4
The maximum distance between the Detector and the host
≤1000m
Machine Weight
≤1500g
Operating Pressure
86~106kPa
Dimensions
190*150*95mm
Range
100ppm
HRP-T1000-NH3
Ammonia Gas Detector (No Lights, LCD Model)
HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (No Lights, LCD Model) Picture

Introduction

HRP-T1000 Gas Detector is used in flammable and explosive gas leakage sites and chemical plant areas where toxic and harmful substances exist. The instrument uses catalytic combustion sensors and electrochemical sensor technology imported from the United States. The product has the advantages of stable signal and high accuracy. The instrument casing is made of The one-time cast aluminum molding is explosion-proof and explosion-proof design, and the wiring method is suitable for various dangerous places.

Instruments are widely used in pharmaceuticals, chemical fertilizers, natural gas pipeline networks, sewage treatment, municipal administration, iron and steel smelting, chlorine plants, acetylene plants, refrigeration workshops, chemical workshops, gas station areas, boiler rooms, hotel kitchen operating rooms, etc. that require poison and fire prevention Explosion-proof place.

Features

◆Detection accuracy and measuring range are adjustable

◆Long life, high sensitivity, low drift, stable and reliable operation

◆Two-level concentration alarm, with relay output function

◆LCD display and working status display

◆With temperature compensation and automatic zero point correction functions

◆4~20mA standard analog output and RS485 digital output, can be uploaded to DCS and PLC systems

◆Infrared remote control allows you to adjust the Detector without opening the cover, which is safe and convenient

◆The explosion-proof design is suitable for hazardous conditions zones 1 and 2.


Detection principle : The system provides 24V standard DC Voltage to the external transmitter, collects
                     the input signal of the standard 4-20mA transmitter, and analyzes and processes it to complete digital display and alarm operations.

Applicable objects : This system supports the input signals of various standard transmitters. Such as gas transmitter: carbon monoxide, hydrogen sulfide,

Gas alarm controller uses and application fields

Used for gas safety detection and alarm in oil exploration, oil and gas transportation, oil refining, metallurgy, power plants, chemical industry, oil depots, liquefied gas stations, mines, tunnels, tunnels, underground pipelines and other places that require fire protection, explosion protection and poisoning prevention.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Knowledge
Standard