China

DONGRU DR9000S anticorrosive layer Thickness Gauge 0~9500μm

SE
Measurement principle electromagnetic induction of DONGRU DR9000S Coating Thickness Gauge, Measurement range 0-9500 μm, error range +/- (3% H + 2 μm), resolution 0.1 μm /1 μm, minimum measurement surface 16 * 16mm, minimum curvature convex 5mm, concave 25mm, thinnest substrate 0.4mm.
$332.00/set
PromotionLoading...
Coupon
Model:

DongRu DR9000S Anti-corrosion layer Thickness GaugeSPEC

DongRu DR9000S Anti-corrosion layer Thickness GaugeDetails

DongRu DR9000S Anti-corrosion layer Thickness GaugePacking list

SKU
NB026887
Measurement principle
Magnetic Induction
Measurement range
0 ~ 9500µm
margin of error
±3%
Resolution
0.1mm | 1mm
Minimum measurement surface
F20,5mm
Minimum radius of curvature
Convex 5mm; Concave 25mm
thinnest matrix
0.4mm
Power
Three (7) alkaline batteries
Operating temperature
0℃-60℃
Relative Humidity
20~90%RH
Total Weight
100g
Complete-built unit size
130*70*25mm
Operating humidity
20% RH - 90% RH, no strong magnetic field environment
Calibrated mode
Zero point calibrated, two point calibrated, multi point calibrated
Unit display
μm / Thousand
Language
Chinese, English
Display screen
2.3-Inch large color screen and large font size display
Shutdown method
Manual/Automatic
Statistical function
MAX Maximum (MAX), MIN Minimum (MIN), Average (MEA), Number of measurements (No)
data storage
It can be stored in 10 groups, 200 in each group, and a total of 2000 data can be stored
Measurement method
Continuous measurement and single measurement
DR9000S
Anti-corrosion layer Thickness Gauge
DONGRU DR9000S anticorrosive layer Thickness Gauge 0~9500μm Picture

Introduction

DR9000S Anti-corrosion Layer Thickness Gauge is a professional non-destructive testing method that applies the principle of electromagnetic induction, according to the national industry: GB/T 4956-1985, GB/T 4956-2003 standards, professionally measuring the thickness of the coating layer on the surface of magnetic metal materials instrument. It can non-destructively measure the thickness of non-magnetic coatings (such as: paint, electrophoresis, powder, galvanized, chromium, copper, indium, enamel, rubber, enamel, anti-corrosion layer, paint) on magnetic metal substrates (such as: steel, iron) etc.), easy to use, easy to carry, super large LCD, large font size, backlight direct reading is clearer, imported high-quality metal material small measuring head, precise and firm structure, better repeatability, and excellent performance.

Features

  • Large range: 0-9500μm or 0-9.5mm

  • Simple operation, fast test speed, good sensitivity and high measurement accuracy

  • Alloy probe, wear-resistant and pressure-resistant, durable, accurate

  • There are two measurement methods: continuous measurement and single measurement

  • There are four statistical functions: maximum value (MAX), minimum value (MIN), average value (MEA), measurement times (No)

  • Large-capacity storage, can be stored in 10 groups, 200 in each group, and can store 2000 data in total

  • Stored data store view delete function

  • Three calibration methods: zero point calibration, two-point calibration, multi-point calibration

  • Upper and lower limit alarm function (can be set in single measurement mode)

  • The operation process is marked by a beep (in single measurement mode)

  • Automatic identification of ferrous and non-ferrous substrates

  • Metric and imperial conversion μm/Mil

  • Sunlight mode (used under strong light)

  • Chinese and English bilingual version

  • 2.3-inch large color screen large font size display

  • Manual/automatic shutdown function

  • Bluetooth synchronous data transmission function (customized)

FAQ
QWhat is the working principle of DR9000S anticorrosive layer thickness gauge?
A Using the principle of electromagnetic induction, nondestructive detection is realized by measuring the thickness of nonmagnetic coating on magnetic metal substrate.
QWhat about the probe of this thickness gauge?
A DR9000S uses wear-resistant, pressure-resistant, durable alloy probes with high accuracy.
QHow to use DR9000S anticorrosive layer thickness gauge for data transmission and operation?
A Users can consult the relevant operating instructions to learn how to use the Bluetooth synchronous data transfer function and operate the Miscellaneous special function to better cope with different working environments.
QWhat Calibration methods are available for thickness gauges?
A The DR9000S supports zero-point calibrated, two-point calibrated and multi-point calibrated Calibration methods to ensure measurement accuracy.
QCan the thickness of galvanized coating be measured?
A Sure.
QGalvanized on the iron parts, and then coated with fireproof paint on the galvanized parts. Now I want to measure the thickness of the fireproof paint, the thickness of the fireproof paint is 2.5mm, and the thickness of the galvanized paint is about 80um to 150um. I don't know if this one can be tested?
A At this time, the measurement is the total thickness. The total thickness of the zinc layer and the fireproof paint can also be used with this one. This one can finally measure 9.5mm, and direct measurement is not possible. Unless the zero position is corrected on the galvanized layer before the fireproof paint is made.
QWhat is the principle of this anti-corrosion layer thickness gauge? Can it measure the coating thickness on tiles?
A Hello, it is the principle of electromagnetic induction, and the film thickness of the tile cannot be measured, and the film thickness of the non-magnetic coating on the magnetic metal substrate (such as steel and iron) can be measured non-destructive.
QDoes the DONGRU anticorrosive layer thickness gauge meet the ASTMB499 standard?
A The DR9000S anti-corrosion layer thickness gauge can be referred to.
Knowledge
Standard