China

ZKHS QL-225 Ozone Aging Test Chamber Ozone Aging Test Chamber

SE
ZKHS QL-225 Ozone Aging Test Chamber size 500X600X750mm, Temperature range RT + 10 ℃~ 70 ℃, 0 ℃~ 70 ℃, Humidity range 65%~ 98% R.H, 40%~ 98% R.H, ozone concentration (low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation +/- 10%, Temperature Fluctuation +/- 0.5 ℃, Humidity stability + 2, -3% R.H.
$12725.00/set
PromotionLoading...
Coupon
Model:
Certificate

ZKHS QL-225 Ozone aging Test ChamberSPEC

ZKHS QL-225 Ozone aging Test ChamberDetails

ZKHS QL-225 Ozone aging Test ChamberPacking list

SKU
NB026912
Interior size
500*600*750mm
Temperature range
RT+10~70℃、 0~70℃
Humidity range
65~98%R.H、40~98%R.H
Ozone concentration range
(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation +/- 10%
Temperature Fluctuation
±0.5℃
Humidity stability
+2、-3%R.H
Sample state
Dynamic, static (optional)
Rotation speed
1Rpm 360 degree swirl/spin sample holder
Flow velocity
12~16mm/S
temperature Controller
Imported LED digital display P, I, D + S, S, R. Microcomputer integrated Controller
time Controller
High-precision hour, minute, second time Controller
Ozone concentration analysis
Imported concentration analysis regulator 4~ 20mA output, RS232 communication port
Ozone generator
Silent discharge tube
Safety protection
Leakage, short circuit, overtemperature, motor overheating, overcurrent protection
Power
5.5KW
Time setting range
0~9999 M, H adjustable
Power supply Voltage
AC380V +/- 10% 50Hz three-phase five-wire system
QL-225
Ozone aging Test Chamber
ZKHS QL-225 Ozone Aging Test Chamber Ozone Aging Test Chamber Picture

Applications

◆The product is suitable for the aging test of sunlight resistance and artificial light source of non-metallic materials.

Cabinet structure

◆ The box body is processed and formed by CNC machine tools, the shape is beautiful and generous, and the box cover is the side buckle handle type, which is easy to operate.

◆ The inner tank of the box is made of imported stainless steel plate, and the shell of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.

◆ The heating method is heating wire, which heats up quickly and the temperature is evenly distributed.

Control system

◆ PT100 temperature sensor, imported instrument control heating, more stable temperature.

◆ The light can be controlled independently, and it can be controlled alternately.

◆ The light control time and the alternating control time can be set arbitrarily within 0~999H.

Meets standards

Strictly refer to: GB/T16777-2008, GB/T12967.4-2014 technical parameters design and manufacturing.

Series selection

Model

QL-100

QL-150

QL-225

QL-500

QL-010

Inner dimensions

450X450X500

500X500X600

500X600X750

700X800X900

1000X1000X1000

Temperature range

RT+10℃~70℃、 0℃~70℃

Humidity range

65%~98%R.H 、 40%~98%R.H

Ozone concentration

(Low concentration) 10~1000PPhm, (High concentration) 1~500PPm, Volatility 10%

Temperature fluctuations

±0.5℃

Humidity fluctuations

+2、-3%R.H

Test setup

Dynamic, static (optional)

Sample frame speed

360 degree rotation of the sample holder (1 revolution per minute)

Gas flow rate

12~16mm/S

Temperature controller

Imported LED digital display P, I, D+S, S, R. microcomputer integrated controller

Time controller

High-precision hour, minute, and second time controllers

Ozone concentration analysis

Inlet concentration analysis regulator 4~20mA output, RS232 communication port

ozonizer

Silent discharge tube type

Security

Leakage, short circuit, overtemperature, motor overheating, overcurrent protection

Total power

4.0KW

4.5KW

5.5KW

6.5KW

7.5KW

Duration of the trial

0~9999 M, H adjustable

Supply Voltage

AC380V±10% 50Hz three-phase five-wire system


FAQ
QOur laboratory needs to do a light aging comparison test of plastic parts. Which configuration should we choose?
A It is recommended to choose the QL-225 with light control function. It supports independent light control and alternating cycle, and the time can be set arbitrarily from 0-999 hours, which is perfectly suitable for the light aging test requirements of plastic parts. The imported LED digital thermostat ensures stable temperature, and with the 360-degree swirl/spin sample holder, each sample can receive light evenly and obtain accurate comparison data.
QHow to choose the model for samples of different sizes?
A Choose according to the sample size: QL-100 for small samples (450 × 450 × 500mm), QL-225 for medium samples (500 × 600 × 750mm), and QL-500 for large samples (700 × 800 × 900mm). For example, QL-225 has a moderate volume, which can accommodate most standard samples without wasting energy. It is a cost-effective choice.
QDoes the ZKHS ozone aging test chamber meet the GB/T16777 standard?
A The QL-225 ozone aging test chamber can refer to
Knowledge
Standard