ZKHS GDW-010B Temperature Cycling Test Chamber -20 ℃~ 150 ℃

SE
Interior size 1000 * 1000 * 1000mm, Temperature range -20~150 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, Cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
$9522.00/set
PromotionLoading...
Coupon
Model:
Certificate

ZKHS GDW-010B Temperature Cycling Test ChamberSPEC

ZKHS GDW-010B Temperature Cycling Test ChamberDetails

ZKHS GDW-010B Temperature Cycling Test ChamberPacking list

SKU
NB026933
Interior size
1000*1000*1000mm
Temperature range
-20~150℃
Temperature fluctuation
≤±0.5℃
Heating rate
-20→100℃≈35min;-40→100℃≈45min
Cooling rate
25~-40℃≈50min;25~-60℃≈65min
display
Large screen touch screen temperature and humidity control instrument
Accuracy range
Setting Accuracy: temperature ± 0.1 ℃, indication Accuracy
Temperature transducer
Platinum resistance PT100Ω/MV
Heating system
Fully independent system, nickel-chromium alloy electric heating heater
Refrigeration system
Original French "Taikang", fully enclosed air-cooled compression refrigeration method
Circulatory system
Temperature-resistant and low-noise air-conditioned motor, multi-leaf centrifugal wind turbine
Enclosure Material
A3 steel plate electrostatic spray treatment
Inner chamber material
SUS304 stainless steel high quality mirror steel plate
Thermal insulation material
Polyurethane Rigid Foam, Ultrafine Glass Fiber Cotton
Door frame insulation
Double Layer High and Low Temperature Conditioning Silicone Rubber Door Seal
Timer
0~9999 M, H adjustable
Safety Devices
Leakage, short circuit, over temperature, motor overheating, compressor overVoltage, overload, overcurrent protection
Power
AC280V ± 10% AC380V ± 10% 50Hz three-phase five-wire system
Environment temperature
5~30℃
Environment humidity
≤85%R.H
Temperature Uniformity
≤±2℃
GDW-010B
Temperature Cycling Test Chamber
Interior size 1000 * 1000 * 1000mm, Temperature range -20~150 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, Cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
ZKHS GDW-010B Temperature Cycling Test Chamber -20 ℃~ 150 ℃ Picture

Description

◆The product is suitable for aerospace products, information electronic instruments, materials, electricians, electronic products, and various electronic components in high-low temperature or humid and hot environment, and inspect their performance indicators. 

Cabinet structure

◆The box body is processed and formed by CNC machine tools, the shape is beautiful and generous, and the non-reaction handle is adopted, which is easy to operate.

◆ The inner tank of the box is made of imported stainless steel (SUS304) mirror panel, and the shell of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.

◆The water replenishment tank is placed in the lower right part of the control box, and has automatic protection for water shortage, which is more convenient for the operator to replenish the water source.

◆ The large observation window is equipped with a light to keep the box bright, and the tempered glass embedded in the heating body is used to clearly observe the situation in the box at any time.

◆ The humidification system pipeline is separated from the control circuit board, which can avoid the failure of the humidification pipeline due to water leakage and improve safety.

◆ The pipeline circuit system of the waterway system adopts the door type opening, which is convenient for maintenance and overhaul.

◆ The box body insulation is made of ultra-fine glass fiber insulation cotton, which can avoid unnecessary energy loss.

◆The left side of the box is equipped with a test hole with a diameter of 50mm, which can be used for external test power cable or signal cable.   

Programmable controllers 

◆The temperature and humidity control instrument adopts (7.0 inches) large screen screen, the screen operation is simple, and the program editing is easy. The operation interface of the controller is available in Chinese and English, and the real-time operation curve diagram can be displayed on the screen.

◆ It has the capacity of 100 sets of programs and 1000 segments of 999 cycle steps, and the maximum value of each period is set to 99 hours and 59 minutes.

◆After the data and test conditions are input, the controller has the function of screen locking to avoid human touch and shutdown.

◆ With RS-232 or RS-485 communication interface, it can design programs on the computer, monitor the test process and perform automatic power on/off functions.

◆ With the function of automatic calculation, the temperature and humidity change conditions can be corrected immediately, so that the temperature and humidity control is more accurate and stable. 

Refrigeration and air circulation system 

◆ The refrigerator adopts the French original "Taikang" fully enclosed compressor.

◆ The refrigeration system is designed with unit or binary cryogenic circuit system.

◆ The multi-wing blower is used to supply air with strong air circulation to avoid any dead angles, which can make the temperature and humidity evenly distributed in the test area.

◆ Wind path circulation air return air design, wind pressure, wind speed are in line with the test standards, and can make the temperature and humidity at the moment of opening the door to stabilize the time quickly, the heating, cooling, humidification system is completely independent and effective, reduce the test cost, increase the life, reduce the failure rate. 

Meets standards 

Strictly refer to: GB/T10592-2008, GB/T10586-2006, GB/T2423.1-2008, GB/T2423.2-2008, GB/T2423.3-2006, GB/T2423.4-2008, GJB150.3A-2009, GJB150.4A-2009 and other relevant standards

Series selection

Model

GDW-100

GDW-225

GDW-500

GDW-800

GDW-010

Inner shape size DXWXH mm

450X450X500

500X600X750

700X800X900

800X1000X1000

1000X1000X1000

Temperature range

A:0℃~150℃  B:-20℃~150℃?? C:-40℃~150℃  D:-60℃~150℃  E:-70℃~150℃

Fluctuation/uniformity

≤±0.5℃/≤±2℃

Heating time

-20°C~100°C for about 35min


-40°C~100°C for about 45min

-70°C~100°C for about 55min

Cool-down time

25°C~-40°C for about 50min


25°C~-60°C for about 65min

25°C~-70°C for about 80min

controller

Large screen touch screen temperature and humidity control instrument

Accuracy range

Setting accuracy: temperature±0.1°C, indication accuracy

Temperature sensor

Platinum resistor PT100Ω/MV

Heating system

Fully self-contained, nickel-chromium alloy electrically heated heater

Refrigeration system

Original French "Taikang", fully enclosed air-cooled compression refrigeration method

circulatory system

Temperature-resistant and low-noise air-conditioning motor, multi-leaf centrifugal wind wheel

Enclosure Material

A3 steel plate electrostatic spraying treatment

Inner box material

SUS304 stainless steel good mirror steel plate

Insulation material

Polyurethane rigid foam, ultra-fine glass fiber foam

Door frame insulation

Double-layer silicone rubber door sealing strip resistant to high-low temperature aging

  Duration of the trial

0~9999 M, H adjustable

  Standard configuration

1 set of multi-layer heating cream with illuminated glass window, 2 sample racks, and 1 test lead hole φ50mm

 Security

Leakage, short circuit, overtemperature, motor overheating, compressor overpressure, overload, overcurrent protection

 Supply Voltage

AC280V±10% AC380V±10% 50Hz three-phase five-wire system

Use ambient temperature

5℃~+30℃ ≤85%R.H


FAQ
QWhat is the difference between this high-low-temperature chamber A and B?
A A is without refrigeration, only high temperature and high humidity, B is with refrigeration, high temperature and high humidity, low temperature and low humidity can be done.
QAre all low/high temperature test chambers available for testing in the GJB150.4A standard?
A Not necessarily, but this GDW-010B low/high temperature test chamber can be considered.
Standard