HZAOC RLH-225 Hot Air Aging Oven, stainless steel liner automatic ventilation system

SE
Stainless steel liner and forced circulation system, Temperature Uniformity +/- 1 ℃, 8-20 times/hour adjustable ventilation, with independent ventilation system and sample holder swirl/spin function to ensure test Stability.
$4159.00/set
PromotionLoading...
Coupon
Model:
Certificate

hzaoc RLH-225 Hot air aging boxSPEC

hzaoc RLH-225 Hot air aging boxDetails

hzaoc RLH-225 Hot air aging boxPacking list

SKU
NB027182
Temperature range
RT+10~300°C
Temperature fluctuation
± 0.5 ℃ (when no load)
Temperature Uniformity
±1℃
Heating rate
3~5℃/min
Timer
1~ 9999 (s, m, h) adjustable
Ventilation time
1~ 99 (s, m, h) adjustable
ventilation Volume
8~ 20 times/hour
Ventilation method
Forced ventilation, forced air intake of the fan, automatic ventilation by adjusting the flow of the flowmeter
Specimen turntable
Two-layer stainless steel swivel
Circular mode
Fan forced circulation method
Power
380V three-phase five-wire system
Liner size
500*600*750mm
Dimensions
1080*1120*1700mm
Turntable speed
10rpm
RLH-225
Hot air aging box
Stainless steel liner and forced circulation system, Temperature Uniformity +/- 1 ℃, 8-20 times/hour adjustable ventilation, with independent ventilation system and sample holder swirl/spin function to ensure test Stability.
HZAOC RLH-225 Hot Air Aging Oven, stainless steel liner automatic ventilation system Picture

Applications

The hot air aging Test Chamber is suitable for heat resistance test of non-metallic materials, ventilation aging test of electronic parts and plasticized products.

Box structure

1. The outer shell is processed by A3 steel plate CNC machine tool, and the inner tank is made of high-quality stainless steel plate. The insulation material is high-density glass fiber cotton, and the thickness of the insulation layer is 150mm.

2. Stirring system: It adopts high-power long-axis fan motor, high-temperature-resistant stainless steel shaft and impeller to achieve strong convection and vertical diffusion cycle. The ventilation system of the equipment is automatically controlled, and the ventilation volume is adjustable.

3. The sample rack is driven by a geared motor and can rotate.

Heating and Humidification System

1. Use far-infrared nickel alloy to heat the heating wire at high speed.

2. Heating and ventilation are completely independent systems.

3. The output power of temperature control is calculated by microcomputer to achieve high precision and effective power consumption

Control System

1. Temperature control: It is controlled by a high-precision touch screen temperature controller.

2. Time control: Imported time relay is adopted, and H, M, S can be set arbitrarily.

3. Electrical components of the equipment: all adopt the "Schneider" brand and domestic (CN) familiar brands.

4. Heating system: Far-infrared kneading chromium alloy is used for high-speed heating and electric heating.

5. The rotation of the sample rack, the control of the ventilation system and the heating system are independent, and are controlled by the switch on the operation panel.

Protection System

Overall equipment overheating, fan overheating protection, overall equipment phase loss/reverse phase protection, overall equipment timing, other protections include leakage, running instructions, automatic shutdown after fault alarm, etc.

Executive standard

1.GB/T3512-2001;

2.JB/T7444;

3.IEC540