China

LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge

SE
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.
$489.00/set
PromotionLoading...
Coupon
Model:
Certificate

LANDTEK CM8856 Coating Thickness GaugeSPEC

LANDTEK CM8856 Coating Thickness GaugeDetails

LANDTEK CM8856 Coating Thickness GaugePacking list

SKU
NB000279
Measurement principle
Magnetic induction + eddy current
Measuring range
0 ~ 1250µm
margin of error
±3%
resolution
0.1mm | 1mm
Minimum radius of curvature
F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm
thinnest matrix
0.3mm
probe
F and NF split probes
icon function
without
Power
2 * AAA battery
Calibrated Certificate
without
Language
Chinese
Display screen
LCD
supporting software
without
Total Weight
81G (without battery)
Complete-built unit size
126*65*27mm
Minimum measurement surface
F6mm
Unit display
μm/mils
Voltage prompt
Low Voltage prompt
Operating Temperature
0~40℃
Relative Humidity
10~90%RH
CM8856
Coating Thickness Gauge
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge Picture

Coating Thickness Gauge Selection Tool

Introduction

LANDTEK statistical surface coating Thickness Gauge has two types: CM8855 and CM8856 surface coating Thickness Gauge, both of which are the same in function. The CM8856 Surface Electroplating Thickness Gauge is a split-type coating Thickness Gauge with an external probe. It is equipped with a probe that can automatically identify the substrate and can measure magnetic metal substrates and non-magnetic metal substrates at the same time. The thickness measuring range of CM8856 surface electroplating layer Thickness Gauge is 0~1250 microns, and the external probe structure design allows the main unit to be freely equipped with different probes. The measurement is accurate, stable and reliable, and it is very convenient to carry.

LANDTEK CM8856 Surface Plating Thickness Gauge (statistical type) is a split-type portable Thickness Gauge. CM8856 Electroplating Thickness Gauge can quickly, without damage, and accurately measure the thickness of coatings and coatings; it can be used in engineering sites and laboratories, and is an instrument needed for material protection.

Features and advantages

* CM8856 electroplating Thickness Gauge can store 99 sets of measurement data; realize the statistical function of the instrument by measuring the average value, maximum value and minimum value.

* Iron-based and non-ferrous-based dual-purpose plating Thickness Gauge.

* There are two optional measurement methods: single and continuous.

* Metric/Imperial unit conversion.

* CM8856 electroplating Thickness Gauge has functions such as manual shutdown, automatic shutdown and underVoltage prompt.

* Automatically memorize the calibration value and automatically identify the material of the measured substrate.

* There is a buzzer sound during operation, but the buzzer does not sound during continuous measurement.

* CM8856 Coating Thickness Gauge can communicate with PC computer by using optional accessory RS232C software and cable to realize functions of data collection, processing, analysis and printing.

* Optional Bluetooth™ data output option is also available.

* The integral instrument is suitable for one-handed operation, with a "big probe", and a large contact surface for better stability, and the results are accurate and repeatable.

The spring guide sleeve probe with wear-resistant hard metal probe can not only measure on hard or rough surfaces, but also ensure that the probe has constant tight force and stable sampling value.

Applications

Surface electroplating layer Thickness Gauge CM8856 uses a magnetic sensor to measure non-ferromagnetic coatings and coatings on ferromagnetic metal substrates such as steel and iron, such as: paint, powder, plastic, rubber, synthetic materials, phosphating layer, chromium, zinc , lead, aluminum, tin, cadmium, porcelain, enamel, oxide layer, etc. Use eddy current sensors to measure enamel, rubber, paint, plastic layers, etc. on copper, aluminum, zinc, tin, etc. substrates. Widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields.

Features

Surface coating Thickness Gauge CM8856 can measure the thickness of the non-magnetic coating on the magnetic conductive object and the non-conductive coating on the non-magnetic metal substrate.

Pictures

Introduction to LANDTEK CM8856 Surface Electroplating Thickness Gauge

LANDTEK CM8856 Surface Plating Thickness Gauge Display

LANDTEK CM8856 Surface Plating Thickness Gauge Interface Details

LANDTEK CM8856 Surface Plating Thickness Gauge Probe Details

LANDTEK CM8856 surface plating layer Thickness Gauge packaging accessories diagram

LANDTEK Surface Coating Thickness Gauge Selection List

LANDTEK Coating Thickness Gauge Selection List

FAQ
QTest aluminum plate and iron plate spray paint, CM8856 can test it?
A OK
QCoating thickness gauge eddy Current principle, is this also divided into two types: phase sensitive amplitude type?
A Not really.
QCan this Coating thickness gauge be applied to ASTMB499?
A OK
QCan this thickness gauge be used with Bluetooth?
A Hello, it is OK. The standard Lantai CM8856 does not have Bluetooth function. If you need a CM8856 with Bluetooth function, you can customize it (the Bluetooth customized version of the CM8856 is the Bluetooth adapter installed in the machine before leaving the factory).
QCM8856 Coating thickness gauge dual function refers to what function?
A Hello! CM8856 Coating thickness gauge dual function means that magnetic induction method and eddy current method can be used for measurement, thank you for your consultation!