INESA WRR Melting point meter (visual)

SE
The initial and final melting points of the samples were detected by visual method, in line with the provisions of the National Pharmacopoeia. With silicone oil as the temperature transfer medium, three samples can be measured simultaneously and the average value can be calculated, which is suitable for the test of dark samples. 0.1 ℃ temperature resolution and adjustable heating rate, support RS232/USB data interface
$1074.00/set
PromotionLoading...
Coupon
Model:

INESA WRR Melting point MeterSPEC

INESA WRR Melting point MeterDetails

INESA WRR Melting point MeterPacking list

SKU
NB027954
Temperature range
RT+~280℃
Measuring method
visual
Temperature Resolution
0.1℃
Heating rate
0.5/1 0/1.5 ℃/3.0 ℃/min Four gears
error of indication
±0.4℃(≤200℃);±0.7℃(>200℃)
Repeatability
±0.3℃(1.0℃/min)
Linear Heating rate error
±10%
processing power
3
Capillary tubing size
Outer diameter φ 1.4mm; Inner diameter φ 1.0mm; Length 120mm
Sample height
3-5mm
Display mode
liquid crystal display
Interface
RS232/USB
Power Supply
220V±22V 50Hz±1Hz
Dimension
270*310*400mm
Net Weight of instrument
11kg
material
plastic
principle
By heating the sample and observing the phase transition process from solid to liquid, the melting point of the sample was determined.
function
Used to measure the melting point of a substance, the temperature at which a substance changes from solid to liquid.
WRR
Melting point Meter
The initial and final melting points of the samples were detected by visual method, in line with the provisions of the National Pharmacopoeia. With silicone oil as the temperature transfer medium, three samples can be measured simultaneously and the average value can be calculated, which is suitable for the test of dark samples. 0.1 ℃ temperature resolution and adjustable heating rate, support RS232/USB data interface
INESA WRR Melting point meter (visual) Picture

Features

The WRR visual melting point meter detects the initial and final melting points of a sample by visual method, in accordance with the provisions of the National Pharmacopoeia.  Silicone oil can be used as the temperature transfer medium to measure three samples at the same time, calculate the average value, and measure dark samples.

FAQ
QIs there a Melting point meter with a temperature of 800 degrees? Measure inorganic salts
A It's not that hot.
QIs this Melting point meter (visual) JB/T6177 compliant?
A The Melting point meter (visual) is suitable for JB/T6177, please consult customer service for detailed application definition
Standard