Germany

QNix 9500Pro Coating Thickness Gauge magnetic Induction probe 1250μm

QNix 9500 enhanced Thickness Gauge, built-in magnetic probe, thickness range 0~1250μm, screen can be flipped, large LCD screen, the shell has three layers of shock protection.

Qnix QNix 9500PFe1.2mm Coating Thickness GaugeSPEC

Qnix QNix 9500PFe1.2mm Coating Thickness GaugeDetails

Qnix QNix 9500PFe1.2mm Coating Thickness GaugePacking list

SKU
NB028240
Measurement principle
Magnetic Induction
Measurement range
0~1250μm
margin of error
±2~3%
Minimum measurement surface
Φ20mm
Minimum radius of curvature
Radius 20mm
thinnest substrate
0.2mm(F)
probe
Integrated probe
Probe material
Ruby (Al203)
Calibrated mode
Zero calibrated, 1 point calibrated, 2 point calibrated, independent (independent adjustment) calibrated
Measurement mode
Manual selection of substrate, automatic selection of substrate, double substrate combined measurement, continuous measurement, button trigger measurement
Unit display
µm/mil conversion
Interface
USB port
Data storage
1000000 measurement readings
Power Supply
2xAA alkaline dry battery/rechargeable battery/USB
Standards
DIN EN ISO 2808, DIN 50981, DIN 50984, ISO 2178, BS 5411 (3 & 11), BS 3900-C5, ASTM B 499, ISO 2360, ASTM D 1400, ASTM D 1186, ASTM D 7091
Display screen
2.4-Inch IPS-LCD color liquid crystal, 600 lumens, 70 ° Viewing Angle
Operating temperature
-20 ℃ -70 ℃
Battery life
When the battery is not in use, 50% Capacity > 1 year, 60,000 times
Protection level
IP64
Machine Weight
175 g
Machine size
155*65*44 mm
Storage temperature
-20~70℃
Probe support
Trogramid®
Body hard material
PA12 GF30
Body soft material
TPE
system clock
CR1220
Battery life
> 2 years
Pin code protection
Yes.
Calibrated value memory
10 groups
QNix 9500PFe1.2mm
Coating Thickness Gauge
QNix 9500 enhanced Thickness Gauge, built-in magnetic probe, thickness range 0~1250μm, screen can be flipped, large LCD screen, the shell has three layers of shock protection.
QNix 9500Pro Coating Thickness Gauge magnetic Induction probe 1250μm Picture

QNix9500, rugged, user-friendly interface, reliable quality, multi-purpose and high precision.

QNix9500 has considerable characteristics for the quality control of product production in the process of industrial anti-corrosion, spraying, and surface treatment, whether in compliance with standards or technical parameters. The newly developed QNix9500 PC software enables faster and more efficient management of documentation and inspection reports than ever before. Every QNix9500 is manufactured entirely in Germany.

Compared with the basic type Thickness Gauge, the enhanced Thickness Gauge adds independent and independent calibration in terms of calibration, with 10 groups of calibration value memory function, continuous measurement mode and pin code protection function. In addition, the measurement can be triggered by pressing a button, and the probe can be placed on the surface of the workpiece for a delayed measurement.

Qnix QNix 9500PFe 1.2mm Coating Thickness Gauge Detail Figure 1

Features

1. High-precision measurementEnsure that the quality results are effective

• High-precision measurement in the full range

• High repeatability of measurement results

• Temperature compensation in the probe

• Guaranteed measurement accuracy on curved surfaces and small workpieces

• Easy indexing on rough, smooth, and curved substrates


2. Solid and durable protectionLong-term use under the conditions of satisfying the evil strategy

• Fiberglass included, consisting of 5 components in accordance with IP64

• Waterproof and light-proof

• Three layers of shock protection

• LCD window glass is scratch and chemical resistant (H6 rating)

• Operating temperature -20°C-70°C

• Stainless steel probe with dust film


3. The use of ergonomic design to save time, can be used quickly and continuously without fatigue

• Overrun indicator, LED directly on the LCD and probe

• High-brightness 24-inch LCD, which can be viewed at a 70° angle

• Adjust the brightness of the LCD automatically or manually under sunlight to the best effect display

• Large tactile buttons and low weight medium

• Flip display 0°, 90°, 180°, 270°


4. Flexibility and scalability

• The main machine can be adapted to Fe (iron-based), NFe (non-iron-based),Fe/NFe (iron-based/non-iron-based) dual-purpose probes

• The main unit can be adapted to other types of probes

• Can be equipped with both integrated and split probes

• Quick and easy plug-and-play probe replacement

• Rapid adaptation to meet different needs


5. Friendly interface that is easy for users to understand, intuitive and operable, saving time and money

• Simple calibration for standard use

• The host and PC software are guided by intuitive menus, and the report can be reached in three steps

• Customizable keys for quick and direct single operation 

• Pre-configured as standard

Diagram of the display

Qnix QNix 9500PFe 1.2mm Coating Thickness Gauge Detail Figure 2

QNIX9500 Thickness Gauge Specification Drawing

Detail Figure 3 of the Qnix QNix 9500PFe 1.2mm Coating Thickness Gauge


FAQ
Q9500Pro Coating thickness gauge is what principle?
A Hello, it is the principle of magnetic induction.
QMeet GB/T 8923.1 Coating thickness gauge
A QNix 9500PFe1.2mm Coating thickness gauge, please refer to it.
Knowledge
Standard