China

BENTING CBX65BE Hot Air Disinfection Box, LCD 65L

SE
BENTING CBX65BE hot air disinfection box adopts LCD and has an overlift preventer. It is an experimental dry baking Autoclave with a volume of 65L. The inner chamber of the CBX65BE hot air disinfection box has 9 layers of Shelf, the Shelf spacing is 35mm, and the heating power is 1.6kw.
Model:
Certificate

BenTing CBX65BE Disinfection boxSPEC

BenTing CBX65BE Disinfection boxDetails

BenTing CBX65BE Disinfection boxPacking list

SKU
NB028575
Temperature range
RT+10~300°C
Temperature fluctuation
±1℃
Temperature Resolution
0.1℃
Temperature Uniformity
±2.5%
Volume
65L
Interior size
400*360*450mm
Inner chamber material
stainless steel plate
Shelf (std.)
2pcs
Shelves (max)
9pcs
Load per shelf
15kg
Timer
0~9999Min (with Timer waiting)
Power
AC220V/7.2A
Input power
1.6Kw
Dimensions
550*550*840mm
Net Weight
44kg
Enclosure Material
Cold rolled steel plate, surface resistance painting
Convection mode
Double duct forced convection
Thermal insulation material
aluminum silicate fiber
heater
Stainless steel heating tube
Exhaust port
Inner diameter 28mm * 1, top
thermostat
Liquid crystal dual row PID
Temperature setting
Tap the four-button settings
Temperature representation
Measuring temperature display: liquid crystal upper display; setting temperature display: liquid crystal lower display
Run function
Fixed value operation, Timer operation, automatic stop
Program Mode
optional
Additional features
Deviation correction, menu button lock, power outage compensation, power outage memory, speed regulating fan, overlift preventer
Temperature transducer
pt100
Safety Devices
Overlift preventer
Packing size
640*640*905mm
Gross Weight
49Kg
Shelf (std.)
4pcs
Shelf spacing
35mm
CBX65BE
Disinfection box
BENTING CBX65BE Hot Air Disinfection Box, LCD 65L Picture

Features

● Rapid, safe and reliable sterilization.

● Convenient operation, fixed value operation, timing operation, automatic stop.

● Special function keys for temperature setting.

● Auxiliary menu to realize overheating alarm, deviation correction and menu lock.

● Vertical double air duct air jacket, centrifugal forced air supply from turbine, more uniform temperature.

● Adjustable speed fan enables light, fine and powdery samples to be used.

● Forced fan heat dissipation and air intake structure, so that the working temperature of the fan is <50°C, and it can run for a long time.

● LCD multi-data full-screen operation display, power failure memory, power failure compensation.

● Overheating preventer

safety

● Overheating alarm, menu lock, overheating prevention

Parameter comparison

modelrated powerInternal volumePartition layers
BX30B/BX30BE0.8kw30LLevel 6
BX45B/BX45BE1.2kw45L7 floors
BX65B/BX65BE1.6kw65L9 floors
BX125B/BX125BE2.3kw125L13 floors
BX230B/BX230BE3.0kw230L17 floors
Other parameters
WayDual duct forced convection
Operating temperature rangeRT+10~300℃
temperature resolution0.1°C
temperature fluctuation±1℃
Temperature distribution accuracy±2.5%
Interiorstainless steel plate
ExteriorCold-rolled steel sheet with chemical-resistant coating on the surface
Insulation materialAluminum silicate fiber
temperature control methodB type: digital tube double row PID; BE type: liquid crystal double row PID
temperature setting methodTouch four buttons to set
Temperature representationType B: measured temperature display: 4-digit upper display; set temperature display: 4-digit lower display
BE type: Measured temperature display: LCD upper display; Set temperature display: LCD lower display
timer0~9999 minutes (with timing waiting function)
running functionFixed value operation, timing operation, automatic stop
program modeOptional
Additional featuresDeviation correction, menu key lock, power failure compensation, power failure memory, speed regulating fan (BE type: overheating preventer)
sensorPt100
safety devicesOverheating alarm (BE type: overheating preventer)
Partition2 pieces
shelf4 pieces
RemarkGX230B/BE non-adjustable speed fan