United States

JENCO 3671N online pH oxidation reduction controller

SE
0~14/0.01 pH, -1990~1990/1mV, two sets of relays control output, automatic temperature compensation 0~100 ℃
$401.00/set
PromotionLoading...
Coupon
Model:

JENCO 3671N pH oxidation controllerSPEC

JENCO 3671N pH oxidation controllerDetails

JENCO 3671N pH oxidation controllerPacking list

SKU
NB002952
PH range
0~14.0pH
PH Measurement Accuracy
±0.1PH
Resolution
0.1pH
Measurement range
Automatic 0~100 ℃
Impedance
Greater than 10 ^ 12 ohms
Power Supply
115/230 VAC ±15%,50/60 Hz
Dimensions
96*48*172mm
Weight
0.69 kg
Measurement range mV
-1990~1990mV
mV resolution
10mV
Measurement Accuracy of mV
±0.1% ±1 digit
Measurement Accuracy of mV
±0.1% ±1 digit
Measurement range
0~100℃
Temperature Resolution
1℃
Measurement Accuracy
1 ±1 digit
Recorder, output (ph)
1400 mV
Recorder, output (mV)
-1990 ~ 1990 mV
Recorder, output (temperature)
1000 mV
Two-point on/off control
pH or ORP (user selectable)
Idle zone (dead band, no sensing zone)
+/- 0.1 pH (per set point)
Relay, output
8a at 115 VAC,4a at 230 VAC
read display
0.5 "active, red LED display
3671N
pH oxidation controller
0~14/0.01 pH, -1990~1990/1mV, two sets of relays control output, automatic temperature compensation 0~100 ℃
JENCO 3671N online pH oxidation reduction controller Picture

JENCO 3671N In-Line pH Redox Controller Features

  • Standard 1/8DIN aluminium body design

  • The LED display can display the pH (ORP) value, and the temperature value can be displayed by the temperature switch button

  • Two sets of pH (ORP) relay control

  • It has the function of automatic temperature compensation

  • Power-off correction value memory function

  • It is an affordable industrial in-line acidity/redox controller

JENCO 3671N Online pH Redox Controller

Optional

ModelIntroduction
IP-600-9PTGeneral water treatment (can be used below 70°C for a long time)
IP-600-1NPTGeneral water treatment (can be used below 90°C for a long time)
IP-600-3CNPTPure water pH composite electrode (pure water and ultrapure water can be used below 60°C for a long time)
IP-600-10General water treatment (use at room temperature)
IP-600-1NGeneral water treatment (use at room temperature)
IP-600-3CNPure water pH composite electrode (used at room temperature for pure water and ultrapure water measurement)

Redox electrodes

ModelIntroduction
IR-500-8General water treatment field
IR-500-9General water treatment field

Sheath tube

ModelIntroduction
009A1 meter tube length

Sealed box

ModelIntroduction
011-200-00Dial-mounted
012-200-00Wall-mounted