There are many types of general-purpose cooling circulating water machines, many specifications, and are very widely used, and small general-purpose cooling circulating water machines can also be used for supporting cooling of laboratory equipment. There are two types of chillers: air-cooled all-in-one and water-cooled. The air-cooled integrated chiller is dissipated by the fan, for the high-power chiller, the fan power is large, the heat dissipation and noise are naturally large, this large heat dissipation chiller, if placed indoors, will inevitably cause the indoor temperature to rise. The use of water-cooled all-in-one machine can solve this problem very well. The water-cooled chiller uses water instead of a fan to dissipate heat, and the product has no heat discharge and low noise indoors, which is a satisfactory environment-friendly product. In addition to the multiple protections of the product system itself, the general-purpose cooling circulating water machine also provides alarm output for the external main equipment to ensure the safety of the external equipment. At the same time, the equipment can also provide a variety of communication interfaces (RS232/RS485/USB) to realize a variety of analog (0-10V or 4-20mA) and switching input and output, and then realize the remote control of the chiller by peripherals, status query and the control of other external components by the chiller.

1. LCD screen, actual temperature, set temperature, and return difference value are displayed at the same time, which is clear at a glance, and the keypad is automatically locked when the operation is timed out without buttons.
2. A variety of pressure pumps are optional, and the output pressure of the pump is adjustable, which can meet a variety of applications with different pressures and different flows.
3. Standby anti-freezing function of water pump
4. It can be remotely controlled to switch on and off
5. Brand compressor, silent fan, silent pump, quiet when working, suitable for applications in quiet environment.
6. The refrigeration system has the functions of high pressure protection and overcurrent protection to prevent the compressor from overload and effectively protect the compressor.
7. When the alarm is applied, the light and sound are reminded at the same time, and various alarm codes are directly displayed, which can directly determine the cause of the fault and the repair method.
8. Caster design, convenient for the machine to move
| Model | Temperature range | Temperature Fluctuation | Cooling capacity | Pump flow | Pump pressure | Sink volume | Dimensions(W x D x H) |
| [℃] | [℃] | [W] | [L/Min] | [bar] | [L] | [mm] | |
| IC010 | 5...35 | ±0.1/1.0 | 1000 | 10 | 0.8 | 8 | 330x510x595 |
| IC012 | 5...35 | ±0.1/1.0 | 1200 | 12 | 4 | 8 | 330x510x595 |
| IC016 | 5...35 | ±0.1/1.0 | 1600 | 22 | 1 | 8 | 330x510x595 |
| IC022 | 5...35 | ±0.1/1.0 | 2200 | 28 | 2.4 | 30 | 520x415x745 |
| IC027 | 5...35 | ±0.1/1.0 | 2700 | 28 | 2.4 | 17 | 440x560x820 |
| IC036 | 5...35 | ±0.1/1.0 | 3600 | 28 | 2.4 | 25 | 530x710x960 |
| IC052 | 5...35 | ±0.1/1.0 | 5200 | 28 | 2.4 | 25 | 530x710x960 |
| IC072 | 5...35 | ±0.1/1.0 | 7200 | 33 | 3.3 | 25 | 530x710x960 |
| IC085 | 5...35 | ±0.1/1.0 | 8500 | 28 | 4.3 | 35 | 555x825x1320 |
| IC145 | 5...35 | ±0.1/1.0 | 14500 | 28 | 4.3 | 70 | 575x1320x1350 |
| IC170 | 5...35 | ±0.1/1.0 | 17000 | 28 | 4.3 | 90 | 775x1650x1800 |
| IC220 | 5...35 | ±0.1/1.0 | 22000 | 120 | 2.6 | 150 | 775x1650x1800 |
| IC290 | 5...35 | ±0.1/1.0 | 29000 | 120 | 3.4 | 180 | 775x1650x1800 |
| IC350 | 5...35 | ±0.1/1.0 | 35000 | 120 | 3.4 | 200 | 775x1650x1800 |
| IC450 | 5...35 | ±0.1/1.0 | 45000 | 130 | 4.3 | 250 | 900x2100x2050 |
| IC600 | 5...35 | ±0.1/1.0 | 60000 | 130 | 4.3 | 270 | 900x2100x2050 |
| IC700 | 5...35 | ±0.1/1.0 | 70000 | 260 | 3.4 | 330 | 900x2100x2050 |
| IC027W | 5...35 | ±0.1/1.0 | 2700 | 28 | 2.4 | 17 | 410x520x735 |
| IC052W | 5...35 | ±0.1/1.0 | 5200 | 28 | 2.4 | 25 | 440x560x820 |
| IC072W | 5...35 | ±0.1/1.0 | 7200 | 33 | 3.3 | 25 | 510x810x1000 |
| IC085W | 5...35 | ±0.1/1.0 | 8500 | 28 | 4.3 | 35 | 510x810x1000 |
| IC145W | 5...35 | ±0.1/1.0 | 14500 | 28 | 4.3 | 70 | 510x810x1000 |
| IC170W | 5...35 | ±0.1/1.0 | 17000 | 28 | 4.3 | 90 | 600x1065x1310 |
| IC220W | 5...35 | ±0.1/1.0 | 22000 | 120 | 2.6 | 150 | 600x1065x1310 |
| IC290W | 5...35 | ±0.1/1.0 | 29000 | 120 | 3.4 | 180 | 720x1230x1450 |
| IC350W | 5...35 | ±0.1/1.0 | 35000 | 120 | 3.4 | 200 | 720x1230x1450 |
| IC450W | 5...35 | ±0.1/1.0 | 45000 | 130 | 4.3 | 250 | 850x1450x1450 |
| IC600W | 5...35 | ±0.1/1.0 | 60000 | 130 | 4.3 | 270 | 1100x1800x1650 |
| IC700W | 5...35 | ±0.1/1.0 | 70000 | 260 | 3.4 | 430 | 1100x1800x1650 |
| IC900W | 5...35 | ±0.1/1.0 | 90000 | 260 | 3.4 | 620 | 1230x2130x1750 |
| The W at the end of the model stands for water-cooled chiller, which can be customized with different refrigeration capacity, different Water Tank volume, different circulation capacity of non-standard products, temperature controller LCD, touch screen | |||||||