China

LABTOP iMCoolero-805 Input Cooler

Certificate

labtop iMCooler-805 input refrigeratorSPEC

labtop iMCooler-805 input refrigeratorDetails

labtop iMCooler-805 input refrigeratorPacking list

SKU
NB030889
Instrument type
input refrigerator
Protection level
I/NFL
Protection level
IP20
Temperature range
-80~40℃
Temperature Fluctuation
±1.0K
Temperature Display mode
LED
Temperature Control mode
Intelligent PID control
Temperature sensor
Pt100
refrigerant
R404A/R23
Cooling Capacity 10 ℃
450x2W
Dimensions
380*480*600mm
Temperature Resolution
0.1℃
Light alarm
Yes
audible alarm
Yes
Calibrating options
Yes
Allow continuous operation
100%
Environmental temperature
5~32℃
Allowable Relative Humidity
80%
Weight
48kg
Power supply Voltage
200~230VAC/50Hz
Instrument noise
≤55db
Technical parameter standard
DIN 12876
iMCooler-805
input refrigerator
LABTOP iMCoolero-805 Input Cooler Picture

Description

The iMCooler805 submersible cooler is equipped with a flexible stainless steel bellows, which can be wound into different shapes and placed in different dewars, and an external PT100 can be placed in the dewars at the same time, which can accurately control the temperature of the liquid inside the dewar, and then accurately control the temperature of the sample in the beaker, with a minimum temperature of -80°C.
The submersible chiller is an excellent choice for continuous refrigeration, which can quickly cool the liquid to low temperature or ultra-low temperature, and can replace dry ice for ultra-low temperature experiments

Features

  • The laboratory replaces ice salt, dry ice, and liquid nitrogen for low temperature tests, and the low temperature reaches -80 °C;

  • It is very convenient to use with the open heating circulator, and the temperature of the bath liquid reaches room temperature or below to achieve rapid cooling;

  • Simple operation;

  • Small size, light weight, can be easily placed on the desktop;

  • Temperature alarm function;

  • When the alarm is raised, the light and sound are reminded at the same time;

  • Temperature calibration function;

  • The key components of the refrigeration system, such as compressors and circulating fans, are imported products.

Comparable models

ModelTemperature rangeTemperature FluctuationCoil sizeHose lengthDimensions
[℃][℃][mm][mm](WxDxH) [mm]
iMCooler-204-20...40±0.5φ40×901200232x420x410
iMCooler-402-40...40±0.5φ50×1201200232x420x410
iMCooler-805-80...40±1.0φ12.5×6501600355x455x865


FAQ
QWhat is the low temperature limit of this iMCoolero-805 input cooler?
A LABTOP iMCoolero-805 meets the Temperature range of -80 to 40 ° C, with a minimum temperature of -80 ° C.
QDoes this input cooler comply with the GB/T26808 standard?
A The input cooler is suitable for GB/T26808. Please consult customer service for detailed application definition.
Standard