China

LABTOP BHC 20 Immersion thermostatic circulator

Model:
Certificate

labtop BHC 20 Immersion thermostatic circulatorSPEC

labtop BHC 20 Immersion thermostatic circulatorDetails

labtop BHC 20 Immersion thermostatic circulatorPacking list

SKU
NB030896
Instrument type
Bridge heating circulator
Protection level
III/FL
Protection level
IP20
Temperature range
(-20)RT+10~220℃
Temperature Fluctuation
0.02±K
Temperature Display mode
LED
Temperature Control mode
Intelligent PID control
Temperature sensor
Pt100
Temperature sensor
optional
Heating power
2000W
Pump type
Pressure/suction pump
Pump adjustability
without
Maximum pump pressure
0.3bar
Maximum suction of pump
0.2bar
Flow rate of pump
22L/min
Pump connection interface
M16x1
Minimum bath depth required
150mm
Dimensions
(345~885)*200*336mm
Temperature Resolution
0.1℃
Light alarm
Yes.
audible alarm
Yes.
Temperature overrun alarm
Yes.
The temperature is not enough alarm
Yes.
secondary protection
Yes.
Low level protection
Yes.
Temperature range
0~260℃
Calibrating options
Yes.
Allow continuous operation
100%
Environmental temperature
5~32℃
Allowable Relative Humidity
80%
RS232 interface
optional
USB port
optional
Weight
10kg
Power supply Voltage
200~230VAC/50Hz
Input Power
2100W
Instrument noise
≤45db
Technical parameter standard
DIN 12876
BHC 20
Immersion thermostatic circulator
LABTOP BHC 20 Immersion thermostatic circulator Picture

Description

The Immersion Thermostat/Controller is a multi-functional heating device that can provide heating, stirring, temperature measurement, temperature control and circulation, using a retractable bridge to easily and quickly install the instrument on any tank with a width of no more than 885mm, to achieve precise temperature control of the sample in the bath, combined with the cooling thermostat circulator, the lowest temperature is -20°C. All models are equipped with powerful pressure and suction pumps and comply with the DIN12876 standard safety class III (FL can be used with flammable liquids). The pump adapter can be used for external circulation temperature control, and the cooling coil is configured for connection to a cold water source.  

Features

  • The retractable bridge allows the instrument to be easily mounted on different Water Tanks;

  • Powerful pressure/suction pumps;

  • Good stability of temperature control;

  • Meets safety class III.(FL) in the DIN12876 standard and can use flammable liquids;

  • Convenient for internal and external circulation applications;

  • High-low temperature alarm function;

  • Over-temperature automatic cut-off/anti-dry burning function;

  • Low level alarm function;

  • Multi-point calibration function;

  • When the alarm is raised, the light and sound are reminded at the same time;

  • Adjustable safety temperature range, safer to use;

  • A variety of communication interfaces can be configured (RS232/USB).

Serial models

ModelTemperature rangeTemperature FluctuationHeating powerPump flowPump pressurePump suctionImmersion depthDimensions
[℃][℃][W][L/Min][bar][bar][mm](WxDxH) [mm]
HC 20ERT+10...100±0.12000120.20.163...130136x151x336
HC 30ERT+10...100±0.13000120.20.163...130136x151x336
HC 20RT+10...220±0.022000220.30.263...130136x151x336
HC 30RT+10...220±0.023000220.30.263...130136x151x336
BHC 20ERT+10...100±0.12000120.20.163...130(345...885)x200x336
BHC 30ERT+10...100±0.13000120.20.163...130(345...885)x200x336
BHC 20RT+10...220±0.022000220.30.263...130(345...885)x200x336
BHC 30RT+10...220±0.023000220.30.263...130(345...885)x200x336


FAQ
QWhat is the minimum controlled temperature for this BHC 20 immersion thermostatic circulator?
A LABTOP BHC 20 meets a Temperature range of -20 to 220 ° C with a minimum temperature of -20 ° C.
Knowledge
Standard