China

Kedian MC-3001 Coating Thickness Gauge

TEC MC-3001 Coating Thickness Gauge is a general-purpose full-split Coating Thickness Gauge, MC-3001 Coating Thickness Gauge is an upgrade of the MC-3000B/S series.
Model:
Certificate

KODIN MC-3001 SPEC

KODIN MC-3001 Details

KODIN MC-3001 Packing list

SKU
NB003101
Measurement principle
Magnetic Induction + eddy Current
Measurement range
F0.5:0~0.5mm;F1.2:0~1.25mm;F3:0~3mm;F5:0~5mm;F9:0~9mm;N1.2:0~1.25mm
margin of error
±3%
Resolution
0.1μm|1μm|0.01mm
Minimum measurement surface
F0.5:6mm;F1.2:9mm;F3:12mm;F5:20mm;F9:20mm;N1.2:9mm
probe
Split probe
Power Supply
2 * AA battery
system language
Chinese, English
Display screen
2.4 inch TFT high definition color screen, 320 * 240 pixels, large digital display
Machine Weight
220G (including battery)
Machine size
150*68*33mm
Operating temperature
-10~40℃
statistical function
Lite mode, Monitoring mode, Statistics mode, MIN Minimum capture
Data storage
10,000 Measured values
Unit display
μm/mils
Relative Humidity
≤90%RH
MC-3001
Kedian MC-3001 Coating Thickness Gauge Picture

Introduction to the MC-3001 Coating Thickness Gauge

The MC-3001 Universal Split Coating Thickness Gauge is a full-scale, multi-functional Split Coating Thickness Gauge upgraded on the basis of the MC-3000B/S series. It can be configured with all the split probes of the electrical instrument, and one host can use both magnetic probes and non-magnetic probes, and can also choose various customized probes such as internal anti-corrosion probes. The user can choose one or more probes for any matching according to their needs, and the corresponding measurement range and measurement material are also different according to the model of the probe.

Features

●Two thickness measurement methods, magnetic and eddy current, can non-destructively measure the thickness of the non-magnetic cladding (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on the magnetic metal matrix (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of the non-conductive cladding (such as rubber, paint, plastic, anodized film, etc.) on the non-magnetic metal matrix (such as copper, aluminum, zinc, tin, etc.).

●6 types of probes (F0.5, F1.2, F3, F5, F9, N1.2) can be used

●With temperature compensation function: equipped with Kedian's new "phase-locked loop" technology

●With screen flip function: You can manually choose to flip the measurement data to display

● Display: 2.4-inch TFT high-definition color screen, 320*240 pixels, large digital display

●Measurement speed: According to different applications, customers can choose two kinds of measurement speeds: single measurement and continuous measurement

●The instrument can be calibrated in three ways, and the systematic error of the probe can be corrected by the basic calibration method

●With storage function: more than 10,000 measurement points can be stored

● With delete function: you can delete one suspicious data in the storage group, and you can also delete all the stored data so that new measurements can be made

●Set the limit: The measured value outside the limit can be automatically alarmed

●Display language: built-in Chinese, English

●Unit of measurement: Metric, Imperial convertible

● With wireless communication function: Bluetooth 2.0, it can communicate wirelessly with computers and printers

●It has the function of power supply under-Voltage indication

●There is a beep prompt during operation

●There are two shutdown modes: manual shutdown mode and automatic shutdown mode

●V-groove: The humanized V-groove structure is convenient for measuring the coating on the outer surface of pipes of various sizes

●Large flat bottom: The special large flat bottom probe structure makes the instrument measurement more stable and repeatable

●Anti-slip mat: The professionally designed anti-slip mat with the anti-slip texture on the back of the chassis makes it easy for customers to get tired for a long time, which reflects the consistent concept of customer first

Probe type

Optionally, see probe schedule

Measurement mode

Compact mode, monitoring mode, statistical mode, minimum value capture

Principle

Magnetic induction and eddy current

Measuring range

Probe decides

Probe connection method

Split conductor connection (arbitrary matching)

Operating temperature

Relative Humidity: ≤90%;   Temperature: -10°C~+40°C

Temperature compensation

It is equipped with the new "phase-locked loop" technology of Kedian

language

Built-in Chinese, English

Measure speed

Depending on the application, customers can choose between single and continuous measurement speeds

power supply

Two size five (AA) batteries

Dimensions of the main unit

150mm(L)*68mm(W)*33mm(H)

weight

220g (including battery)

MC-3001 Coating Thickness Gauge Probe Model


Probe model

F0.5

F1.2

F3

F5

F9

N1.2

Principle

magnetic induction

Eddy current

Measuring range

0-0.5mm

0-1.25mm

0-3mm

0-5mm

0-9mm

0-1.25mm

Resolution (μm)

0.1

0.1

0.1

10

10

0.1

error

± (1~3%) H±1 or H±2μmNote: H is the thickness value of the measured cladding

Display accuracy

0~100μm: 0.1μm;   100~999μm: 1μm;   1mm~9mm: 0.01mm

Minimum plane diameter of the substrate

6mm

9mm

12mm

20mm

20mm

9mm

Minimum radius of curvature (concave)

5mm

6mm

7.5mm

10mm

10mm

6mm

Minimum radius of curvature (convex)

1.5mm

1.5mm

2mm

5mm

5mm

1.5mm


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard