China

FLOM FFX12002-RO laboratory ultra-pure water machine, two-stage reverse osmosis (RO) 120L/H

FLOM FFX12002-RO laboratory ultra-pure water machine adopts unique membrane treatment technology and accessories in the United States, which can adapt to different municipal tap water in various places. The water quality of the produced water is secondary water. FFX12002-RO laboratory ultra-pure water machine adopts double-stage reverse osmosis (RO), conductivity ≤ 0.5μS/cm, resistivity ≥ 2MΩ .cm, and the flow velocity of water production is 30-120L/h.
Model:

FLOM FFX12002-RO Laboratory ultrapure water machineSPEC

FLOM FFX12002-RO Laboratory ultrapure water machineDetails

FLOM FFX12002-RO Laboratory ultrapure water machinePacking list

SKU
NB031929
Product name
FFX basic analysis
Produced water quality
secondary water
Reverse osmosis (RO)
double stage
Flow Rate
120L/H
Inlet source
Municipal tap water
source water pressure
0.15 Mpa~0.5Mpa
Inlet temperature
5-40℃
Conductivity
≤0.5μS/cm
resistivity
≥2MΩ.cm
Flow velocity
1-2L/min
Soluble Silicon (SiO2)
<0.02mg/L
Absorption
< 0.01 (254Nm.1cm optical path)
Host size
600*540*1350mm
Weight
80kg
FFX12002-RO
Laboratory ultrapure water machine
FLOM FFX12002-RO laboratory ultra-pure water machine, two-stage reverse osmosis (RO) 120L/H Picture

Features

1 4.3 LCD touch screen control system has abnormal operation self-diagnosis (raw water, pure water, ultra-pure water quality and quantity), warning function, with consumables and membrane service life display and replacement reminder function;

2. Unique membrane treatment technology and accessories in the United States, which can adapt to different municipal tap water in various places;

3. The reverse osmosis system has the function of automatic manual and timed flushing, which effectively protects and prolongs the service life of the RO membrane;

4. Fully enclosed pipeline design to avoid secondary pollution and maintain stable water quality; Internal one-key disinfection and pressure relief;

5. Automatic continuous water production, real-time operation status display, adjustable operating parameters;

6. The water production system and the circuit system are completely separated, which effectively eliminates potential safety hazards;

7 Chinese and English language switching function (factory default is Chinese), more in line with your language habits;

8. The equipment conforms to (National Laboratory Water Standard GB/T6682-2008), Chinese National Standard for Electronic Grade Ultrapure Water (GB/T11446.1-1997), and American Test Grade Water (CAP, ASTM, NCCLS) standards;

9. The company has passed the EU CE certification and ISO9001-2008 international quality management system certification;

Matching:

1. Water leakage alarm: it can be buzzered alarm, or it can receive the FLOM module to send a text message alarm to the user's mobile phone (the user needs to provide a SIM card);

2. Wireless remote control: control UP, RO water intake and "confirm" to turn off the buzzer alarm sound;

a. Remote control distance of 200 meters.

b. Remote control switch UP, RO water intake.

c. The buzzer alarms when there is no water when the remote control is turned off.

d. Remote control power off and power on.

3. FLOM SMS Sending Module:

a. Send SMS to the user's mobile phone to prompt water leakage alarm and replace consumables.

b. The user can remotely control the functions of turning on and off the computer and taking water by sending SMS.

c. Support input alarm information mass sending function: the content of the alarm SMS can be sent to the mobile phones of different users.

d. Support the parameters of the mobile phone SMS remote rewriting module.

e. Support RS232 serial port to rewrite various parameters (PLC control system is required).                  

f. Multiple user numbers can be configured to control the FLOM module for SMS, when one of the user numbers controls the device through command SMS, the other user numbers will receive the command sent by which authorized number and what is the content of the control SMS sent, so that the responsibility of each user number can be clarified. Prevent the person responsible from being found after a control error.

4. The equipment can be changed to three water outlets according to the customer's requirements.

5. Choose to reserve R232/USB communication interface, which can be connected to the printer and print water quality parameters (PLC control system is required);

Applications:

· FYY (basic application): physical and chemical analysis experiments, hydrogen generators, test vessel flushing, cleaning machines, laboratory animal drinking water, high-purity steam generators, sterilizers and other instruments, ultrapure water system pre-unit with distilled water as the source water;

· FFX (Basic Analysis): Routine qualitative analysis experiments such as biochemical instrument, solution preparation, preparation of chemical reagents, buffers, culture media, university student experiments, physical and chemical testing, etc.;

· FBZ (standard reagent): used for buffer preparation, chemical analysis and inspection of atomic absorption (AA), atomic fluorescence (AFS), effective liquid chromatography (HPLC), mass spectrometry (MC), plasma emission spectroscopy (ICP);

· FCR (depyrogen-removing type): amino acid analysis, protein purification, electrophoresis/gel analysis, animal and plant cell culture, molecular biology experiments and other projects, electrophoresis, molecular biology experiments, PCR;

· FDY (Low Organics): Ion Chromatography, Trace Metal Analysis, Preparation of High Purity Standard Solution, Quantitative Analysis of Trace Elements, HPLC Effective Liquid Chromatography, Toxicity Detection, HPLC, TOC Analysis, IC, GC/MS, ICP/MS Analysis;

· FJY (Genetic Research):D NA/RNA Preparation and Sequencing, HPLC (Amino Acids, Penicillin Analysis), Protein Purification/Analysis, Toxicity Testing, TOC Testing, IVF, PCR, Cell and Tissue Culture, Capillary Electrophoresis, Biology

FAQ
QDoes this ultra-pure water machine meet the GB/T22804 standard?
A This ultra-pure water machine is suitable for GB/T22804. Please consult customer service for detailed application definition.
Knowledge
Standard