| Measurement range | 2.50~125.00mm (single echo); 2.50~60.00mm (multiple echoes) |
| Probe Frequency | 5MHz |
| Probe style | Split probe (UTG M (multiple echoes)) |
| Probe diameter | F13mm |
| Measurement error | ±0.03mm |
| Display resolution | 0.01mm |
| unit system | mm/inch |
| Calibration method | Two or three point calibrated |
| Measurement mode | Single echo, multiple echoes (through paints) |
| Storage Capacity | 250 pieces |
| Statistical function | Average, standard deviation, Min/Max Film thickness and number of readings |
| Standards | ASTM E797 |
| Display | High resolution LCD display |
| Operating language | Chinese, English |
| Interface | USB |
| Application software | Yes. |
| Protection level | Protection against solvents, acids, oils, water and dust |
| Power | 3 * 7 battery |
| Host size | 146*61*28mm |
| Weight | 140G (excluding batteries) |
Warranty days: 365 days
Non-artificially caused product quality problems, the manufacturer will be free of charge during the warranty period, and only the cost of spare parts will be charged outside the warranty period;
1-year warranty for the host and 6-month warranty for the probe, except for other accessories and consumables;