Qiwei ORP-2 portable ORP meter is a high-precision instrument for laboratory measurement of mV value, with dual functions of MV temperature, standard ORP electrode and temperature electrode, ORP-2 portable ORP meter measuring range mV: (0~ ± 1999) mV, resolution 1mV, temperature range (0~60) ℃.
$165.00/set
PromotionLoading...
Coupon
Model:
Certificate

QiWei ORP-2 Portable ORP meterSPEC

QiWei ORP-2 Portable ORP meterDetails

QiWei ORP-2 Portable ORP meterPacking list

SKU
NB033572
Measurement range
mV:(0~±1999)mV
resolution
1mV
Measurement range
0~60℃
basic configuration
ORP electrode, [suitable for solution temperature (5~ 60) ℃ range measurement] battery; temperature electrode; calibration reagent
Measurement parameter
ORP
ORP-2
Portable ORP meter
Qiwei ORP-2 Portable ORP Meter Picture

Applications

The digital display ORP meter is a high-precision instrument for measuring mV values in the laboratory. It has dual functions of MV temperature, standard ORP electrode and temperature electrode, fast response and good stability. The instrument is suitable for industrial and mining enterprises, scientific research, agriculture, medicine, teaching, environmental protection and other units to measure the electrode potential (mV value) of aqueous solution.

operation method

1. Standard reagent configuration method:

Add 60ML distilled water to one package of standard reagents, fully dissolve and stir, and it can be used after 30 minutes.

2. Instrument Calibration

Switch to the calibration mode, wash the electrode with distilled water and dry it. Put in the calibration solution 256mV, stir to make it fully contact, after the reading is stable, press the confirm key, and the calibration is completed.

3. Instrument measurement

Switch to the measurement mode, put the electrode into the solution to be tested, stir to make it fully contact, after the reading is stable, press the confirmation key, and the value displayed on the screen is the correct reading of the solution to be tested.

Electrode use and precautions

1. Storage of ORP electrode: After the electrode is cleaned, put it into a saturated solution of KCL.

2. Cleaning of the ORP electrode: If the platinum head of the electrode is found to be dirty and the measured value in the standard solution of PH=4 exceeds the standard value, it should be cleaned.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard