China

China Vacuum chuck coater TBJ-X2-XB bar + Drawdown blade with imported bar

SE
Bar + Drawdown blade + Vacuum chuck three-in-one, standard high-precision imported bar, accuracy of 1 micron; baseplate is aluminum alloy, external vacuum pump; Universities & colleges hot selection small coater, touch screen operation, Drawdown blade thickness adjustable, film thickness range 0~ 10mm.
$3102.00/set
PromotionLoading...
Coupon
Model:

zy TBJ-X2-XB Automatic Film ApplicatorSPEC

zy TBJ-X2-XB Automatic Film ApplicatorDetails

zy TBJ-X2-XB Automatic Film ApplicatorPacking list

SKU
NB033805
Coating method
Bar + adjustable drawdown blade
Drawdown blade type
Integrated drawdown blade
Drawdown blade Accuracy
±0.003mm
Drawdown blade thickness range
0.001-10Mm adjustable
Length of drawdown blade
400mm
Drawdown blade material
304 stainless steel
Mayer Rod Thickness Range
1-571.5 μm (Spreader thickness according to bar model)
Mayer Rod Accuracy
±0.001mm
Coating speed
5-200Mm/s (< 5mm/s can be customized)
Coating size
300 * 400Mm (Miscellaneous size can be customized)
Spreader distance control
The number can be set arbitrarily within the range of 1-400mm
Vacuum Area
300 * 400Mm (can be customized)
vacuum aperture
Φ1.2mm
Vacuum hole spacing
20*20mm
Vacuum pump size
380*180*280mm
Substrate clamping method
Vacuum adsorption
Control mode
Touch screen control
Power supply Voltage
220V  50HZ
Dimension
630 * 410 * 520Mm (length * width * height)
Net Weight
65KG
speed control
Infinitely variable speed
Bottom plate material
aluminum alloy
Optional Accessories
Leakage tank, substrate fixture, trimming horizontal height support foot device, Glass plate, silicone pad and Weight (for applications with uneven thickness of Spreader substrate), application width control baffle
customizable function
Automatic lame plating device, UV curing device, automatic inking system, air knife drying, remote control, upper infrared heating, double extrusion Spreader
TBJ-X2-XB
Automatic Film Applicator
Bar + Drawdown blade + Vacuum chuck three-in-one, standard high-precision imported bar, accuracy of 1 micron; baseplate is aluminum alloy, external vacuum pump; Universities & colleges hot selection small coater, touch screen operation, Drawdown blade thickness adjustable, film thickness range 0~ 10mm.
China Vacuum chuck coater TBJ-X2-XB bar + Drawdown blade with imported bar Picture

product description

TBJ-X small-scale coating testing machine for inspection all adopts imported accessories, and the price is excellent and low. It has been favored by many R&D institutions of multinational companies, many familiar universities and scientific research institutions at home and abroad. By controlling the speed and stable pressure to ensure the effect of coating and glue, to ensure the uniformity and stability of coating and glue.

Since the main factors affecting the coating film are the coating speed and the pressure applied on the Film Applicator, etc., the coatings painted by hand are often inconsistent, especially the differences between different people are even greater, which is why This makes it difficult to compare test results between samples. The company's automatic Film Applicator is carefully designed to allow the operator to conveniently apply precise wet films on different substrates, which greatly improves the reproducibility of the coating film.

The automatic coating machine is equipped with 1 domestic (CN) wire rod and 1 imported wire rod with a coating film precision as high as 1 μm.



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 1



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 2



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 3



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 4



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 5



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 6



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 7



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 8



CHINA Vacuum adsorption Applicator TBJ-X2-Coating Bar + scraper, with imported bar Figure 9


Optional

Coating wire bar applicator

Coating film test paper

Drawdown Plate

FAQ
QIs there an automatic coating applicator? Apply adhesive on the film between 5-40um viscosity up to 3000
A Metering rod & doctor blade Vacuum adsorption Film Applicator.
QCoating, Resin Solution Substrate metal substrate, film PET Film thickness a few microns to more than 100 microns Heating is not required
A Vacuum adsorption coater with metering rod & doctor blade TBJ-X2-XB
QSimilar to toner, the substrate is a metal sheet, a few tenths of a millimeter thick, if the substrate is uneven, is there a way to apply it?
A Film Applicator with metering rod & doctor blade vacuum adsorption, TBJ-X2-XB
QGlass or PET film is the substrate, is there any smaller one? The substrate is 20 cm wide
A Recommended TBJ-X2-XB Vacuum adsorption metering rod & doctor blade Integrated Lab Film Applicator
QScrape film on special materials, similar to film, polyethylene (PE) film Make a double-decked film. Thickness 20~ 30μm Natural drying
A Vacuum adsorption type with metering rod & doctor blade
Q Film Applicator Generally, it is formed on the surface of aluminum foil, copper foil, PET and other substrates. Slurry used in lithium batteries To doctor blade, do not heating, film thickness 1-10um, commonly used 5 microns
A Recommended metering rod & doctor blade vacuum adsorption, Use a removable doctor blade
QApply PSF Pebax, the substrate has Glass polymer film or the like, the layer is within 100 microns, most of them are thinner 50 microns 20 microns 10 microns 1 micron
A Vacuum adsorption coater with metering rod & doctor blade
QCoat the tinplate with epoxy resin
A Vacuum adsorption type with metering rod & doctor blade
Qhttps://www.nbchao.com/p/31410/ How to ensure that the sample fits perfectly with the platform when Spreader? Applicator rod in hand when applying to press down? Is the sample also very flat? Otherwise, the thickness of the ink layer will be inconsistent.
A Vacuum adsorption type with metering rod & doctor blade; The wire rod Spreader is fully in contact with the substrate, the equipment is under constant pressure, and no additional pressure is required by hand.
QPressure sensitive adhesive on pet It was coated with rollers before, and there is no quantification. Put it in the oven before drying
A Vacuum adsorption with metering rod & doctor blade
Knowledge
Standard