China

NELE DL-1005 Circulating Chiller 5L/-10 ℃

SE
-10~ RT ℃, storage tank volume 5L, cooling capacity 900W, temperature display accuracy 0.01 ℃, thermostatic accuracy +/- 0.5 ℃, pump maximum Flow rate 13L/min
$818.00/set
PromotionLoading...
Coupon
Model:
Certificate

Nele DL-1005 Circulating ChillerSPEC

Nele DL-1005 Circulating ChillerDetails

Nele DL-1005 Circulating ChillerPacking list

SKU
NB034492
Temperature range
-10~RT℃
Tank Volume
5L
cooling Capacity
900W
Temperature display Accuracy
0.01℃
Thermostatic Accuracy
±0.5℃
Flow rate of pump
13L/min
drainage
Yes.
Storage tank material
S304 brushed stainless steel material
Enclosure Material
Anti-aging electrostatic spraying
DL-1005
Circulating Chiller
-10~ RT ℃, storage tank volume 5L, cooling capacity 900W, temperature display accuracy 0.01 ℃, thermostatic accuracy +/- 0.5 ℃, pump maximum Flow rate 13L/min
NELE DL-1005 Circulating Chiller 5L/-10 ℃ Picture

System features:

This series of products is a cryogenic liquid circulation equipment that adopts mechanical refrigeration, which has the function of providing cryogenic liquid and low-temperature Water Bath. Available for rotary evaporator, vacuumCirculating refrigeration of freeze-Drying Ovens, circulating water Vacuum Pumps, ultraviolet Spectrophotometer s, magnetic stirrers and other instruments to carry out multi-functional chemical reactions and biology at low temperaturesreactions, reactions, etc.

The microcomputer intelligent control system, the fully enclosed compressor, the refrigeration microcomputer, can be set to 0~9999 minutes, the timing shutdown, the digital display resolution is +0.01 °C, and the large-screen LCD display has a microcomputer softwareThe lock function is carried out on the microcomputer touch soft key.

Features

  • Digital display resolution: 0.01°C

  • Temperature fluctuation: +0.05

  • The temperature range can be controlled: -120~room temperature


Features

  • Imported brand of fully enclosed environmentally friendly compressor refrigeration system (Panasonic of Japan or Taikang of France).

  • Temperature range: optional -50 ~ room temperature (medium according to the temperature range of pure water, ethylene glycol, alcohol);

  • Temperature control function: Insert the integrated new generation PID automatic temperature control program, equipped with a large screen high-brightness LCD screen, Chinese and English comparison display, digital display resolution

  • 0.01°C to ensure the stable operation of the equipment.

  • Capacity range: 5L, 10L, 15L, 20L, 30L, 50L, 100L, can also be designed and produced in accordance with the user's requirements.

  • The internal circulation function adopts a heatless centrifugal circulation pump to avoid the traditional water pump from affecting the temperature field of the tank due to its own heat production. The internal circulation system is a porous U-shaped reflux circulation principleThe design achieves a high degree of uniformity in the flow and temperature fields of the flow and temperature fields in the tank.

  • The fuselage shell is made of anti-aging electrostatic spraying technology, and the inner tank and table top are made of good S304 brushed stainless steel.

  • The finely crafted front panel and countertop, coupled with the unique humanized R-rounded corner design structure, can prevent operators from inadvertently being injured by edges and corners.

  • The water discharge system can meet the needs of various laboratories and enterprises for production and liquid exchange.

  • Safety protection device:

1. It has the function of power-off protection

2. It has the function of setting the upper and lower limit temperature alarm

3. Low water level protection and alarm function

4. Temperature runaway protection and alarm function

5. The heating device has the function of low water level anti-dry burning and explosion-proof

6. Compressor overheating and overcurrent multiple protection functions

DL Series

ModelMinimum operating temperatureCold sink volumeCooling capacity
DL-1005-105900
DL-1505-1551200
DL-2005-2051400
DL-3005-3051900
DL-4005-4051200
DL-1510-15101400
DL-2010-20101800
DL-3010-30102300
DL-4010-40103200
DL-1015-10152200
DL-2015-20152500
DL-3015-30153000
DL-1020-10202700
DL-2020-20203000
DL-3020-30203500
DL-4020-40204200
DL-1030-10303200
DL-2030-20303600
DL-3030-30304300
DL-4030-40305600
DL-1050-10504700
DL-2050-20505000
DL-3050-30505800
DL-4050-40506300
DL-10100-101004500
DL-20100-201009500
DL-30100-3010011000
DL-40100-4010013000
Same parameters
Pump flow13L/min
Constant temperature accuracy±0.5℃
Temperature fluctuations±0.05℃
Temperature resolution0.01°C
drainYes
Pure water at a cooling capacity of 20°C
Units: °C, L, W
FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.