China

FANGZHOU FZ-670 two-in-one electrode measurement mixed liquid sample

SE
FANGZHOU FZ-670 two-in-one electrode measurement range 0-14.00pH, temperature range 5-60 ℃, branch material Glass shell, FZ-670 two-in-one electrode application range Suitable for measurement of mixed liquid samples: no precipitation after long-term placement of water samples, good flowability, such as: juice, beer, milk, blood protein, alcohol.
Model:
Certificate

FZchina FZ-670 Two-in-one electrodeSPEC

FZchina FZ-670 Two-in-one electrodeDetails

FZchina FZ-670 Two-in-one electrodePacking list

SKU
NB035584
PH range
0~14.00pH
Temperature range
5-60℃
Branch pipe material
Glass shell
reference type
Single salt bridge
reference type
Ag/Agcl
hydraulic junction
Ceramic sand core salt bridge
sensitive film
bulb
inner filling solution
Fillable
Connector
BNC
Application
Suitable for measurement of mixed liquid samples: no precipitation after long-term placement of water samples, good flowability, such as: juice, beer, milk, blood protein, alcohol.
FZ-670
Two-in-one electrode
FANGZHOU FZ-670 two-in-one electrode measurement mixed liquid sample Picture

LABOratory Special Sample Electrode

modelFZ-610 two-in-one electrodeFZ-620 two-in-one electrodeFZ-630 two-in-one electrode
Measuring range2-12.00pH2-12.00pH0-14.00pH
temperature range5-90℃5-90℃5-60℃
Branch materialglass shellglass shellglass shell
Reference structureDouble fluid worldDouble fluid worldsingle salt bridge
Reference typeAg/AgclAg/AgclAg/Agcl
liquid junctionCyclic PTFE bridgeCeramic Sand Core Salt BridgeCeramic Sand Core Salt Bridge
Sensitive filmBulbLow Impedance BulbBulb
Filling fluidnot fillablecan be filledcan be filled
interfaceBNCBNCBNC
ApplicationSuitable for measuring samples with high-low ionic strength: acid rain, rainwater, tap water, seawater, supply water, distilled water, sewage.Suitable for measuring low conductivity samples: water samples with low conductivity and low concentration of H+ or OH- ions, such as: measuring pure water and ultrapure water, water for injection, distilled water, sterilized purified water, soft surface water.Suitable for measuring samples that are easy to block the electrode: the components in the sample have strong adhesion and very little water, and are easy to adhere to the surface of the glass bulb or reference salt bridge, such as: emulsion, food, cosmetics, pigments , paint, soil, sewage.
modelFZ-640 two-in-one electrodeFZ-650 two-in-one planar electrodeFZ-660 two-in-one electrode
Measuring range0-14.00pH0-14.00pH0-14.00pH
temperature range0-80℃0-80℃0-80℃
Branch materialglass shellplastic caseglass shell
Reference structuredouble salt bridgesingle salt bridgedouble salt bridge
Reference typeAg/AgclAg/AgclAg/Agcl
liquid junctionAnnular Sand Core Salt BridgeSand core + PELLON salt bridgeRing Sand Core Double Salt Bridge
Sensitive filmBulbshort hairBulb
Filling fluidcan be fillednot fillablecan be filled
interfaceBNCBNCBNC
ApplicationSuitable for measurement: samples containing protein, samples containing silver ions.Ideal for pH measurement of solid and semi-solid soft, wet surfaces. Such as: agar medium, meat products, dough, paper, skin, cheese, jelly.Suitable for organic sample measurement, special external reference filling liquid.
modelFZ-670 two-in-one electrodeFZ-680 two-in-one planar electrodeFZ-690 two-in-one electrode
Measuring range0-14.00pH0-14.00pH0-14.00pH
temperature range5-60℃0-60℃0-90℃
Branch materialglass shellplastic caseglass shell
Reference structuresingle salt bridgesingle salt bridgedouble salt bridge
Reference typeAg/AgclAg/AgclAg/Agcl
liquid junctionCeramic Sand Core Salt BridgeAnnular Sand Core Salt BridgeCeramic Sand Core Salt Bridge
Sensitive filmBulbshort hairBulb
Filling fluidcan be fillednot fillablenot fillable
interfaceBNCBNCBNC
ApplicationSuitable for measuring mixed liquid samples: water samples have no precipitation after long-term storage, and have good fluidity, such as: fruit juice, beer, milk, blood protein, wine.Ideal for pH measurement of solid and semi-solid soft, wet surfaces. Such as: agar medium, meat products, dough, paper, skin, cheese, jelly.It is suitable for the measurement of strong acid, strong alkali and some organic samples. Such as: organic samples, according to organic samples with external salt bridge.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard