TENLIN HX-4015 Low temperature thermostatic circulator - 40 ℃/ +/- 0.05 ℃ 15L

SE
TENLIN HX-4015 low temperature thermostatic circulator Temperature range -40-100 ℃, Power 3kw, tank volume 15L, pump Flow rate 13L/min, head 3m, HX-4015 low temperature thermostatic circulator has the advantages of fast cooling speed and strong temperature Stability.
Model:
Certificate

TenLin HX-4015 Low temperature thermostatic circulatorSPEC

TenLin HX-4015 Low temperature thermostatic circulatorDetails

TenLin HX-4015 Low temperature thermostatic circulatorPacking list

SKU
NB036056
Temperature range
-40-100℃
temperature resolution
0.01℃
Temperature fluctuation
±0.05℃
Dimensions
450*540*990mm
power
3kw
Tank Volume
15L
Pump flow
13L/min
pump head
3m
Circular mode
Internal/external circulation
HX-4015
Low temperature thermostatic circulator
TENLIN HX-4015 Low temperature thermostatic circulator - 40 ℃/ +/- 0.05 ℃ 15L Picture

Features

1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.

2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.

3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.

4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, upper and lower limits of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.

5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.

6. The accurate temperature correction function can reach 0.01℃, and the temperature fluctuation can reach up to ±0.02℃~±0.05℃ (depending on the model).

external structure

Figure 1: Outline structure of constant temperature bath

Figure 1: Outline structure of constant temperature bath

Figure 2: Bath control panel

Figure 2: Bath control panel

Model parameters

modeltemperature rangepowertank volume
HX-080-100℃1.6kw8L
HX-0508-5-100℃1.6kw
HX-1008-10-100℃1.7kw
HX-2008-20-100℃1.8kw
HX-3008-30-100℃2kw
HX-4008-40-100℃2.3kw
HX-0100-100℃1.8kw10L
HX-0510-5-100℃1.9kw
HX-1010-10-100℃2kw
HX-2010-20-100℃2.1kw
HX-3010-30-100℃2.4kw
HX-4010-40-100℃2.8kw
HX-0150-100℃2.1kw15L
HX-0515-5-100℃2.1kw
HX-1015-10-100℃2.2kw
HX-2015-20-100℃2.3kw
HX-3015-30-100℃2.5kw
HX-4015-40-100℃3kw
HX-0200-100℃2.3kw20L
HX-0520-5-100℃2.4kw
HX-1020-10-100℃2.5kw
HX-2020-20-100℃2.6kw
HX-3020-30-100℃2.8kw
HX-4020-40-100℃3.2kw
HX-0300-100℃2.3kw30L
HX-0530-5-100℃2.4kw
HX-1030-10-100℃2.5kw
HX-2030-20-100℃2.7kw
HX-3030-30-100℃3kw
HX-4030-40-100℃3.5kw
Other parameters
temperature resolution0.01°C
temperature fluctuation±0.05℃
pump flow13L/min
lift3m

    

FAQ
QI would also like to consult the HX-4015 Thermostatic bath. Can this be connected to two refrigeration plates with different temperatures?
A No.
QDo you have a larger capacity? It can better improve the cooling efficiency. Also, what is the size of the pipeline connecting between the top plate and the cold bath? Can you provide it?
A Use 20L for larger ones, and you can provide silicone tubes with an inner diameter of 10mm and an outer diameter of 17mm, three meters.
QCan you cycle for a long time? It is enough to let the temperature of the refrigeration plate reach, and the maintenance time may be longer. Chill down the liquid. I think it is alcohol and ethylene glycol. Is there any Miscellaneous refrigerant that is more inert?
A The best way is to use industrial alcohol The inert one has oil, but the oil will enter a large amount of condensate after a long time, which will affect the cooling effect
QVertical low temperature Thermostatic bath DC-4020 Temperature range -40~ 100 ℃, tank volume 20L, how much can be used for external circulation? Want to use such a refrigeration plate for refrigeration, Power can meet the requirements? The refrigeration plate is placed on a cylindrical soil with a diameter of 60 cm and a height of 180 cm, and it is frozen from top to bottom. The cylinder is 59cm in diameter and 2cm in thickness, and it is filled with refrigeration liquid about 5.7L.
A It is recommended to use the HX series. This refrigeration plate can be cooled to minus tens of degrees, but this soil sample is 1.8 meters, and the height is relatively large. I am not sure whether the cooling capacity can be transferred to the top. The equipment is -40 degrees, and the external circulation to the cold plate may only be -38 ° C, which is cold loss. The volume is 15L, and 6L is beaten out. Just add some liquid into it.
QCan this be externally connected to two refrigeration plates with different temperatures? Can two different temperature outputs be realized?
A No.
QDo I need any Miscellaneous accessories to connect the refrigeration unit?
A Silicone tube and thermal insulation tube need additional equipment.
QCan this TENLIN low temperature thermostatic circulator correspond to GB/T26808?
A Yes, please refer to the NBchao standards page for specific standards.
QWhat is the low temperature limit of this HX-4015 cryogenic thermostatic circulator?
A Minimum temperature -40 ℃