China

TENLIN HX-4020 Low temperature thermostatic circulator - 40 ℃/ +/- 0.05 ℃ 20L

SE
TENLIN HX-4020 low temperature thermostatic circulator Temperature range -40-100 ℃, Dimension 450 * 540 * 990mm, Power 3.2kw, tank volume 20L, pump Flow rate 13L/min, head 3m.
Model:
Certificate

TenLin HX-4020 Low temperature thermostatic circulatorSPEC

TenLin HX-4020 Low temperature thermostatic circulatorDetails

TenLin HX-4020 Low temperature thermostatic circulatorPacking list

SKU
NB036062
Temperature range
-40-100℃
temperature resolution
0.01℃
Temperature fluctuation
±0.05℃
Dimensions
450*540*990mm
power
3.2kw
Tank Volume
20L
Pump flow
13L/min
pump head
3m
Circular mode
Internal/external circulation
HX-4020
Low temperature thermostatic circulator
TENLIN HX-4020 Low temperature thermostatic circulator - 40 ℃/ +/- 0.05 ℃ 20L Picture

Features

1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.

2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.

3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.

4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, upper and lower limits of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.

5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.

6. The accurate temperature correction function can reach 0.01℃, and the temperature fluctuation can reach up to ±0.02℃~±0.05℃ (depending on the model).

external structure

Figure 1: Outline structure of constant temperature bath

Figure 1: Outline structure of constant temperature bath

Figure 2: Bath control panel

Figure 2: Bath control panel

Model parameters

modeltemperature rangepowertank volume
HX-080-100℃1.6kw8L
HX-0508-5-100℃1.6kw
HX-1008-10-100℃1.7kw
HX-2008-20-100℃1.8kw
HX-3008-30-100℃2kw
HX-4008-40-100℃2.3kw
HX-0100-100℃1.8kw10L
HX-0510-5-100℃1.9kw
HX-1010-10-100℃2kw
HX-2010-20-100℃2.1kw
HX-3010-30-100℃2.4kw
HX-4010-40-100℃2.8kw
HX-0150-100℃2.1kw15L
HX-0515-5-100℃2.1kw
HX-1015-10-100℃2.2kw
HX-2015-20-100℃2.3kw
HX-3015-30-100℃2.5kw
HX-4015-40-100℃3kw
HX-0200-100℃2.3kw20L
HX-0520-5-100℃2.4kw
HX-1020-10-100℃2.5kw
HX-2020-20-100℃2.6kw
HX-3020-30-100℃2.8kw
HX-4020-40-100℃3.2kw
HX-0300-100℃2.3kw30L
HX-0530-5-100℃2.4kw
HX-1030-10-100℃2.5kw
HX-2030-20-100℃2.7kw
HX-3030-30-100℃3kw
HX-4030-40-100℃3.5kw
Other parameters
temperature resolution0.01°C
temperature fluctuation±0.05℃
pump flow13L/min
lift3m

    

FAQ
QDo you have a larger capacity? It can better improve the cooling efficiency. Also, what is the size of the pipeline connecting between the top plate and the cold bath? Can you provide it?
A Use 20L for larger ones, and you can provide silicone tubes with an inner diameter of 10mm and an outer diameter of 17mm, three meters.
QWhat is the size of the line connecting the roof to the cold bath? Can you provide it?
A Silicone tubes with an inner diameter of 10 mm and an outer diameter of 17 mm can be provided, three meters.
QChill down liquid is alcohol and ethylene glycol, there is no Miscellaneous more inert refrigerant?
A The best way is to use industrial alcohol, which is inert and has oil, but the oil will enter a large amount of condensate over time, which will affect the cooling effect.
QCan an external cold plate be connected to control the temperature to -40 ° C?
A External circulation to the cold plate may only be -38 ° C, with cold loss. It is recommended to choose a lower temperature
QI want to do a test about the GB/T26808 standard, is this low temperature thermostatic circulator okay?
A Sure
QWhat is the low temperature limit of this HX-4020 cryogenic thermostatic circulator?
A Minimum temperature -40 ℃
Standard