China

TENLIN DC-3015C Program Temperature Control Low Temperature Circulating Bath - 30 ℃/ +/- 0.05 ℃ 15L

SE
Temperature range -30~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, Power 2.4kw, Tank volume 15L
Model:
Certificate

TenLin DC-3015C Programmed Temperature Control Low Temperature Circulating BathSPEC

TenLin DC-3015C Programmed Temperature Control Low Temperature Circulating BathDetails

TenLin DC-3015C Programmed Temperature Control Low Temperature Circulating BathPacking list

SKU
NB036132
Temperature range
-30~100℃
temperature resolution
0.01℃
Temperature fluctuation
±0.05℃
Dimensions
400*450*940mm
power
2.4kw
Tank Volume
15L
Tank opening Dimensions
250*160mm
groove depth
200mm
Pump flow
6L/min
Heating rate
0~1.2℃/min
Cooling speed
0-0.8℃/min
DC-3015C
Programmed Temperature Control Low Temperature Circulating Bath
Temperature range -30~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, Power 2.4kw, Tank volume 15L
TENLIN DC-3015C Program Temperature Control Low Temperature Circulating Bath - 30 ℃/ +/- 0.05 ℃ 15L Picture

Features

1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.

2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.

3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.

4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, the upper limit of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.

5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.

6. The accurate temperature correction function can reach 0.1°C, and the temperature fluctuation can reach up to ±0.1°C~±0.5°C (depending on the model).

external structure

Figure 1: Outline structure of constant temperature bath

Figure 1: Outline structure of constant temperature bath

Figure 2: Bath control panel

Figure 2: Bath control panel

Model parameters

modeltemperature rangepowertank volume
DC0506C-5~1000.87.5L
DC1006C-10~1000.9
DC2006C-20~1001
DC3006C-30~1001.5
DC4006C-40~1002.1
DC0510C-5~1001.310L
DC1010C-10~1001.5
DC2010C-20~1001.8
DC3010C-30~1002
DC4010C-40~1002.1
DC0515C-5~1002.115L
DC1015C-10~1002.2
DC2015C-20~1002.3
DC3015C-30~1002.4
DC4015C-40~1002.5
DC0520C-5~1002.320L
DC1020C-10~1002.4
DC2020C-20~1002.5
DC3020C-30~1002.6
DC4020C-40~1002.7
DC0530C-5~1002.530L
DC1030C-10~1002.6
DC2030C-20~1002.7
DC3030C-30~1002.7
DC4030C-40~1003
Other parameters
resolution0.01°C
Volatility±0.05℃
Heating rate0-1.2/min
cooling rate0-0.8/min
Unit: Temperature °C Size mm Flow L/min Power Kw