China

SK/MIC-800-CO-Y/5% portable carbon monoxide Detector, carbon monoxide CO infrared NDIR 5% vol

SE
Denyment Sensors, detect gas carbon monoxide CO, range 0~5% vol, resolution 0.1% lel, detection principle infrared NDIR, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S, long-term drift ≤ +/- 3% (F.S/year), response time ≤ 10S
Certificate

Skyeaglee SK/MIC-800-CO-Y/5% Portable carbon monoxide DetectorSPEC

Skyeaglee SK/MIC-800-CO-Y/5% Portable carbon monoxide DetectorDetails

Skyeaglee SK/MIC-800-CO-Y/5% Portable carbon monoxide DetectorPacking list

SKU
NB037070
Detection gas
Carbon monoxide CO
range
0 ~ 5% vol
Resolution
0.1% lel
Sensors principle
Infrared NDIR
Operating Mode
Pump suction
Sampling Accuracy
≦3%F.S
Sexual repeability
3%F.S
Long term drift
≤±3% (F.S/年)
Response time
≤10S
Warm-up period
30S
Operating Current
≤50mA
data storage
USB data collection, 300,000 group information storage
service life
3 years
Operating Pressure
86kpa-106kpa
Shell material
Anti-corrosion plastic, aluminum alloy
Operating temperature
-30~50℃
Environment humidity
10~95% RH non-condensing
Storage temperature
-30~70℃
Dimensions
228 * 84 * 50.5mm excluding sampling tube
Weight
1.5kg
Explosion-proof sign
Exia II CT4
SK/MIC-800-CO-Y/5%
Portable carbon monoxide Detector
Denyment Sensors, detect gas carbon monoxide CO, range 0~5% vol, resolution 0.1% lel, detection principle infrared NDIR, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S, long-term drift ≤ +/- 3% (F.S/year), response time ≤ 10S
SK/MIC-800-CO-Y/5% portable carbon monoxide Detector, carbon monoxide CO infrared NDIR 5% vol Picture

SK/MIC-800 series handheld Gas Detectors use EFM ultra-low power consumption 32-bit ARM, the sensor adopts a professional imported catalytic combustion sensor, and the sensor part uses a two-stage high-precision low-temperature drift amplifier and a highly stable power supply. The processing circuit ensures that the instrument detects fast, accurate, stable and repeatable, making the instrument the most professional and stable Gas Detector and leak Detector in the world. The instrument adopts a large full-color 3.5-inch TFT screen, supports Chinese and English, and graphic menu operation, which is easy for users to operate.

Features

Adopt imported high-precision sensors;

High-precision low-temperature drift amplifiers and stable power processing circuits are used;

TFT3.5-inch full-color display, graphical menu, Chinese and English display, providing real-time detection trend analysis chart;

Data storage function, can store 200,000 sets of data, and the storage interval is adjustable;

USB interface for high-speed data transmission, print data can be downloaded;

Built-in long-life imported micro sampling pump, adjust the cleaning air circuit through gear;

Comply with explosion-proof certification, explosion-proof grade: Exia Ⅱ CT4

Shell two-color mold: non-slip, waterproof, dustproof, explosion-proof

Functions

Pump suction detection method: divided into three gears, low-grade, medium-grade and high-grade

Monitor the concentration of gases in the environment or confined spaces and alarm

With self-calibration function, zero-point calibration function, multi-point calibration function

With temperature and pressure compensation, it can well realize the compensation of gas concentration in different temperature and pressure environments

One-click factory reset function can avoid the trouble of misoperation

Gas concentration unit LEL,% LEL can quickly switch the display;

With self-programming function, alarm parameters, STEL and TWA function parameters can be set

There are two detection modes: normal detection mode and patrol mode;

The detection gas circuit has an automatic cleaning function, which automatically prompts the failure of the instrument, the expiration and failure functions of the sensor calibration, and the real-time display characteristics of the detected maximum value, STEL, TWA and concentration value

Dimensions

SK/MIC-800 Portable Formaldehyde Detector1


Series

GasRangeMax. errorMin. readingResponse timeT90
EX
0-100%LEL<±3%(F.S)0.1%LEL≤10s
0-100%Vol<±3%(F.S)0.1%Vol≤10s
CH40-100%LEL<±3%(F.S)0.1%LEL≤10s
0-100%Vol<±3%(F.S)0.1%Vol≤10s
O20-30%Vol<±3%(F.S)0.01%Vol≤10s
0-100%Vol<±3%(F.S)0.01%Vol≤10s
0-5000ppm<±3%(F.S)1ppm≤30s
N20-100%Vol<±3%(F.S)0.01%Vol≤10s
CO0-100ppm<±3%(F.S)0.1ppm≤25s
0-1000ppm<±3%(F.S)0.1ppm≤25s
0-2000ppm<±3%(F.S)0.1ppm≤25s
0-20000ppm<±3%(F.S)1ppm≤25s
0-100000ppm<±3%(F.S)1ppm≤25s
CO20-500ppm<±3%(F.S)1ppm≤20s
0-2000ppm<±3%(F.S)1ppm≤20s
0-5000ppm<±3%(F.S)1ppm≤20s
0-50000ppm<±3%(F.S)1ppm≤30s
0-20%Vol<±3%(F.S)0.01%Vol≤30s
0-100%Vol<±3%(F.S)0.01%Vol≤30s
CH2O0-10ppm<±3%(F.S)0.001ppm≤30s
0-10ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤50s
O30-1ppm<±3%(F.S)0.001ppm≤20s
0-5ppm<±3%(F.S)0.001ppm≤20s
0-50ppm<±3%(F.S)0.01ppm≤20s
0-100ppm<±3%(F.S)0.01ppm≤20s
0-2000ppm<±3%(F.S)0.1ppm≤30s
0-30000ppm<±3%(F.S)1ppm≤30s
0-20mg/L<±3%(F.S)0.01mg/L≤30s
H2S0-10ppm<±3%(F.S)0.001ppm≤30s
0-50ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
0-10000ppm<±3%(F.S)1ppm≤45s
SO20-10ppm<±3%(F.S)0.001ppm≤30s
0-20ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-500ppm<±3%(F.S)0.1ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
0-10000ppm<±3%(F.S)1ppm≤30s
NO0-10ppm<±3%(F.S)0.001ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
NO20-10ppm<±3%(F.S)0.001ppm≤25s
0-100ppm<±3%(F.S)0.01ppm≤25s
0-1000ppm<±3%(F.S)0.1ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
NOX0-10ppm<±3%(F.S)0.001ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
CL20-10ppm<±3%(F.S)0.001ppm≤30s
0-20ppm<±3%(F.S)0.01ppm≤30s
0-200ppm<±3%(F.S)0.1ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
NH30-50ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-1000ppm<±3%(F.S)0.1ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
0-100%LEL<±3%(F.S)0.1%LEL≤10s
H20-100%LEL<±3%(F.S)0.1%LEL≤10s
0-1000ppm<±3%(F.S)0.1ppm≤30s
0-20000ppm<±3%(F.S)1ppm≤30s
0-40000ppm<±3%(F.S)1ppm≤30s
0-100%Vol<±3%(F.S)0.01%Vol≤20s
He0-100%Vol<±3%(F.S)0.01%Vol≤20s
Ar0-100%Vol<±3%(F.S)0.01%Vol≤20s
Xe0-100%Vol<±3%(F.S)0.01%Vol≤20s
HCN0-30ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
HCL0-20ppm<±3%(F.S)0.01ppm≤30s
0-200ppm<±3%(F.S)0.1ppm≤30s
PH30-5ppm<±3%(F.S)0.001ppm≤30s
0-25ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s
CLO20-1ppm<±3%(F.S)0.001ppm≤30s
0-10ppm<±3%(F.S)0.01ppm≤30s
0-200ppm<±3%(F.S)0.01ppm≤30s
ETO0-100ppm<±3%(F.S)0.01ppm≤30s
0-1000ppm<±3%(F.S)0.1ppm≤30s
0-100%LEL<±3%(F.S)1%LEL≤30s
COCL20-1ppm<±3%(F.S)0.001ppm≤20s
0-50ppm<±3%(F.S)0.01ppm≤20s
SiH40-1ppm<±3%(F.S)0.001ppm≤30s
0-50ppm<±3%(F.S)0.01ppm≤30s
F20-1ppm<±3%(F.S)0.001ppm≤30s
0-10ppm<±3%(F.S)0.01ppm≤30s
0-50ppm<±3%(F.S)0.01ppm≤30s
HF0-10ppm<±3%(F.S)0.01ppm≤30s
0-50ppm<±3%(F.S)0.01ppm≤30s
HBr0-50ppm<±3%(F.S)0.01ppm≤30s
B2H60-10ppm<±3%(F.S)0.001ppm≤30s
AsH30-1ppm<±3%(F.S)0.001ppm≤30s
0-10ppm<±3%(F.S)0.01ppm≤30s
0-50ppm<±3%(F.S)0.01ppm≤30s
GeH40-2ppm<±3%(F.S)0.001ppm≤30s
0-20ppm<±3%(F.S)0.01ppm≤30s
N2H4
0-1ppm<±3%(F.S)0.001ppm≤30s
0-300ppm<±3%(F.S)0.1ppm≤30s
THT0-100mg/m3<±3%(F.S)0.01mg/m3≤60s
Br20-10ppm<±3%(F.S)0.001ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s
C2H20-100%LEL<±3%(F.S)0.1%LEL≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-1000ppm<±3%(F.S)0.1ppm≤30s
C2H40-100%LEL<±3%(F.S)0.1%LEL≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)0.1ppm≤30s
CH3CHO0-10ppm<±3%(F.S)0.01ppm≤30s
C2H6O0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s
CH6O0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s
CS20-50ppm<±3%(F.S)0.01ppm≤30s
0-5000ppm<±3%(F.S)0.01ppm≤30s
C3H3N0-50ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s
CH5N0-50ppm<±3%(F.S)0.01ppm≤30s
I20-50ppm<±3%(F.S)0.01ppm≤30s
C8H80-200ppm<±3%(F.S)0.1ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
C2H3CL0-100ppm<±3%(F.S)0.01ppm≤30s
C2HCL30-100ppm<±3%(F.S)0.01ppm≤30s
C2CL40-100ppm<±3%(F.S)0.01ppm≤30s
N2O0-100ppm<±3%(F.S)0.01ppm≤30s
NF30-100ppm<±3%(F.S)0.01ppm≤30s
H2O20-100ppm<±3%(F.S)0.01ppm≤30s
CH3Br0-100ppm<±3%(F.S)0.01ppm≤30s
0-30000ppm<±3%(F.S)1ppm≤30s
0-200g/m3<±3%(F.S)0.1g/m3≤30s
SO2F20-100ppm<±3%(F.S)0.01ppm≤30s
0-5000ppm<±3%(F.S)1ppm≤30s
0-10000ppm<±3%(F.S)1ppm≤30s
C6H60-10ppm<±3%(F.S)0.01ppm≤30s
0-100ppm<±3%(F.S)0.01ppm≤30s
0-2000ppm<±3%(F.S)1ppm≤30s


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard