China

Bante M852 Six-in-one STIP-scan pH conductivity TDS salinity dissolved oxygen, temperature

SE
Bante M852 six-in-one STIP-scan can measure pH, conductivity, TDS, salinity, dissolved oxygen, temperature, salinity range 0~10.00ppt, pH range -1.00~15.00pH, TDS range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt, conductivity range 0~20.00, 2000.0, 2000 µS/cm, 20.00mS/cm, Temperature Measurement range 0~60 ℃.
Model:
Certificate

Bante M852 Six-in-one STIP-scanSPEC

Bante M852 Six-in-one STIP-scanDetails

Bante M852 Six-in-one STIP-scanPacking list

SKU
NB037192
Salinity range
0~10.00ppt
pH Measurement range
-1.00~15.00pH
TDS range
0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Conductivity Detector Measurement range
0~20.00, 200.0, 2000µS/cm, 20.00mS/cm
DO range
0.0~20.0mg/L
DO% Measurement range
0.0~200.0%
Temperature Measurement range
0 ~60°C/32~140°F
M852
Six-in-one STIP-scan
Bante M852 six-in-one STIP-scan can measure pH, conductivity, TDS, salinity, dissolved oxygen, temperature, salinity range 0~10.00ppt, pH range -1.00~15.00pH, TDS range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt, conductivity range 0~20.00, 2000.0, 2000 µS/cm, 20.00mS/cm, Temperature Measurement range 0~60 ℃.
Bante M852 Six-in-one STIP-scan pH conductivity TDS salinity dissolved oxygen, temperature Picture

Measurement parameters

• pH, conductivity, TDS, salinity, dissolved oxygen, temperature

technical features

pH Unit Functional Characteristics

• Round pH sensitive membrane, fully sense the pH value of the liquid.

• 1 to 3 point calibration, automatically recognize USA or NIST standard buffer.

• Automatic temperature compensation to ensure accurate measurement of the full scale range.

• Setup menu to customize pH buffer standards, number of calibration points, temperature units, etc.

EC unit functional characteristics

• Platinum conductivity electrode, providing accurate and reliable measurement results.

• 1 to 3 point calibration, automatic identification of conductivity standard solution.

• Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.

• Setup menu to customize the number of calibration points, TDS coefficient, temperature unit, etc.

DO unit functional characteristics

• Equipped with polarographic electrodes.

• 1 or 2 point calibration, using air saturated water or zero oxygen liquid.

• Salinity and barometric pressure compensation to eliminate measurement errors.

• Automatic temperature compensation to ensure accurate measurement of the full scale range.

• Setup menu to customize the number of calibration points, concentration units, temperature units, etc.

general features

•Automatic end point locking, keeping stable readings for easy viewing and recording.

• Automatic power off, effectively saving battery power consumption.

• Reset function, automatically restores the instrument to factory default settings.

Standard configuration

• M852 6-in-1 Water Quality Detector

• E201-BNC-10K triple combination pH electrode

• pH standard buffer reagents (pH4.00, 6.86, 9.18)

• CON-1-10K platinum conductivity electrode

• Conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm)

• DO100 Dissolved Oxygen Electrode

• Electrolyte

• Electrode membrane cap

• 1.5V LR44 battery *9 pieces (installed in the meter)

• Carrying case