China

CSB Zahn Cup YONGLIDA No. 3 Zahn Cup

SE
Viscosity range 100~800cSt, flow hole diameter 3.76mm, capacity 44ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, Applicable standard ASTM D4212, Environmental temperature 25 +/- 0.2 ℃.
$127.00/piece
PromotionLoading...
Coupon
Model:
Certificate

YongLiDa CSB-3 Zahn Cup (Immersion)SPEC

YongLiDa CSB-3 Zahn Cup (Immersion)Details

YongLiDa CSB-3 Zahn Cup (Immersion)Packing list

SKU
NB003846
Viscosity range
​100~800cSt
Flow hole diameter
3.76mm
Capacity
44ml
Cup body material
stainless steel
Filter material
stainless steel
Handle material
stainless steel
Applicable standard
ASTM D4212
Environment temperature
25±0.2℃
Certificate
without
Correction factor
0.95~1.05
CSB-3
Zahn Cup (Immersion)
Viscosity range 100~800cSt, flow hole diameter 3.76mm, capacity 44ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, Applicable standard ASTM D4212, Environmental temperature 25 +/- 0.2 ℃.
CSB Zahn Cup YONGLIDA No. 3 Zahn Cup Picture

Introduction to CSB ZAHN Cup

Yonglida CSB ZAHN Cup is a portable, immersion type Viscosity Cup, also known as Chai's cup, CSB-2 is a ZAHN Viscosity Cup with an outflow aperture of 2.74mm . The CSB ZAHN Cup complies with the provisions of ASTM D4212-93 "Standard Test Method for Immersion Viscosity Cups", and is used to test the viscosity of Newtonian or near-Newtonian liquids.

CSB series model

modelcup numberApertureMeasuring range
CSB-1125~60
CSB-222.7420~250
CSB-333.76100~800
CSB-444.26200~1200
CSB-555.28400~1800
Unit: mm, cSt
Other parameters
Cup volume44ml
Correction factor(0.95~1.05) 25℃±0.2℃

FAQ
QWhat is the function of the correction coefficient in the Zahn Cup test?
A The correction factor is the factor required to correct the outflow time at 25 ° C +/- 0.2 ° C. It takes into account the effect of temperature on the viscosity test to ensure the accuracy of the test results.
QWhy is the Environmental temperature required to be 25 ° C +/- 0.2 ° C in the CSB Zahn Cup test?
A Environmental temperature Stability has a great influence on the test results. Temperature range of 25 ℃ +/- 0.2 ℃ is to ensure the conformity of test conditions and ensure the accuracy and comparability of viscosity test results.
QIs there a 3 #Zahn Cup that inks viscosity?
A This one fits
QDoes the CSB Chase Cup meet the ASTM D4212 standard?
A Hello, satisfied.
QCan the YONGLIDA CSB-3 Zahn cup meet the ASTMD4212 standard?
A Applicable, you can consult the customer service of the mall for details about the ASTMD4212 standard.
Knowledge