China

FANGRUI BZY200 automatic Surface Tensiometer interfacial tension instrument, platinum plate method

SE
Test range 0~500mN/m, platinum plate method, 4.3-inch touch screen, high sensitivity, high precision, high repeability Sensors, automatic measurement, no need to calculate, directly display surface tension value or interfacial tension value, real-time display measurement Linear dispersion
$1496.00/set
PromotionLoading...
Coupon

FangRui BZY200 board method Surface TensiometerSPEC

FangRui BZY200 board method Surface TensiometerDetails

FangRui BZY200 board method Surface TensiometerPacking list

SKU
NB038525
Measurement method
Platinum plate method
Surface tension Measurement range
0~500mN/m
Surface tension Accuracy
0.01mN/m
Operation mode
Automatic lifting, automatic measurement
Display
4.3-Inch touch screen, direct data reading
Measurement time
Within 60 seconds
Data Interface
RS232 (printer optional)
Dimensions
280*200*360mm
Net Weight
8kg
Power
110V或220V、30W
BZY200 board method
Surface Tensiometer
Test range 0~500mN/m, platinum plate method, 4.3-inch touch screen, high sensitivity, high precision, high repeability Sensors, automatic measurement, no need to calculate, directly display surface tension value or interfacial tension value, real-time display measurement Linear dispersion
FANGRUI BZY200 automatic Surface Tensiometer interfacial tension instrument, platinum plate method Picture

BZY100, BZY200 are the upgraded products of BZY-101, BZY-102, BZY-201, BZY-202, etc. The performance has been greatly improved.

BZY100&BZY200 Surface Tensiometer is widely used in the quality control process related to surface interfacial tension, such as emulsifier or wetting agent and cleaning agent detection. It has the characteristics of reliable performance, easy to use, independent of computers and other equipment, and can provide accurate and reliable analysis in the case of a large number of sample testing requirements. BZY100&BZY200 is controlled by automatic motor to realize fast switching of precise surface and interfacial tension measurement.

Features

  1. Using 4.3-inch touch screen, all operations and information are completed or displayed on the screen;

  2. The sensor adopts the principle of electromagnetic force balance, with high sensitivity, high precision and high repetition;

  3. Both platinum plate method and platinum ring method are used;

  4. Fully automatic measurement, without calculation, directly display the surface tension value or interfacial tension value;

  5. One-key reset, one-key correction; digital processing technology, no deviation;

  6. Users can use standard samples (distilled water and pure ethanol) to calibrate the data to ensure the accuracy of the measurement;

  7. Display measurement curves in real time, save measurement results, print main parameters, data and curves;

  8. Double-door transparent plexiglass Wind Shield, easy to operate and reduce the use of environmental requirements;

  9. Password management function to ensure data traceability and prevent data modification and accidental deletion;

  10. Chinese/English interchange operation

Standards

We attach great importance to the repeatability and standardization of measurement results. The design of BZY100&BZY200 complies with all GB/T, EU, ISO, DIN specifications and ASTM standards on surface and interfacial tension.

ASTM D971 Standard Test Method for Interfacial Tension of Oil-Water by Ring Method

ASTM D1331 Standard Test Method for Surface and Interfacial Tension of Surfactant Solutions

ASTM D1417 Standard Method for Testing Synthetic Rubber Latex

DIN EN 14210 Surfactants - Determination of interfacial tension of surfactant solutions by the stirrup or suspension ring method

DIN EN 14370 Surfactants - Determination of surface tension

ISO 304 Surfactants - Determination of surface tension by the pulling film method

ISO 1409 Plastics/rubber — Polymer dispersions and rubber latexes (natural and synthetic) — Determination of surface tension by the ring method

ISO 4311 Anionic and nonionic surfactants — Determination of critical micelle concentration — Method for determination of surface tension using a hanging plate, stirrup ring or ring

OECD 115 OECD Guidelines for Testing Chemicals: Surface Tension of Aqueous Solutions

ISO 6889 Surfactants - Determination of surface tension by the pulling film method

GB/T 22237-2008 Determination of Surface Tension of Surfactants  

JB/T 9388 -2002 Technical Conditions for Interfacial Tensiometer  

JB/T 18396-2001 Determination of surface tension by natural latex ring method  

SH/T 1156-95 Determination of surface tension of synthetic latex  

GB/T 6541 - 86 Determination of interfacial tension between oil and water of petroleum products (ring method)  

ISO 1409-1995 Determination of surface tension of plastics, rubber, polymer dispersions and latex

ISO 6295-1983 Determination of interfacial tension of petroleum products, mineral oil and oil on water (ring method)  

GB/T 5549 (ISO304-1985) Determination of Surface Tension by Pull-up Film Method  

GB 15308-2006 Foam fire extinguishing agent

GBT 11276-2007 Determination of Critical Micelle Concentration of Surfactants

GB-T 22237-2008 Determination of Surface Tension of Surfactants

Application

Part of application
ink, inkAnalysis of printing/coating tendency, wetting, quality control
detergentAnalyze the absorption speed and properties of surfactants, and study the appropriate concentration
Chemical aidAbility to Study Aggregation and Diffusion Behavior
cosmeticAnalyze the dispersion, stability and wettability of emulsions or suspensions
platingAnalyze wettability for quality control
Pesticides, traditional Chinese medicineAnalysis of adsorption, dispersion, stability and other capabilities
paintAnalysis of dispersion, stability, wetting, etc.
Petroleum product oil such as transformer oilThe value of oil-water interfacial tension is closely related to the purity of new oil and the deterioration of operating oil
water treatmentSewage treatment, water quality analysis


FAQ
QI want to measure the surface tension of the cleaning agent, which instrument is good?
A Measurement accuracy of the BZY200 surface tensiometer using platinum plate method, can quickly and accurately analyze the absorption rate and properties of surfactants in cleaning agents, help you optimize the formulation concentration. It is easy to operate, fully automatic measurement, direct display of results, ideal for quality control. And comply with many international standards, such as ASTM D1331, to ensure reliable data.
QWe do cosmetic research and development, and we need to measure the interfacial tension of emulsion. Is BZY200 suitable?
A BZY200 is suitable. It supports platinum plate method and ring method, which can accurately measure the dispersion, Stability and wetness of cosmetic emulsions or suspensions. The instrument adopts electromagnetic force equilibrate Sensor, which has high Sensitivity and Repeatability. It can also display Linear dispersion in real time and save data for easy analysis and comparison. Meet ISO 1409 and other standards to ensure the development process specification.
QI want to test the surface tension of the cleaning agent to see which active agent works well and which of your instruments is more suitable?
A It is recommended that you use the BZY200 plate method surface tensiometer. It adopts the platinum plate method, which can quickly and accurately measure the surface tension value of the cleaning agent, help you analyze the absorption speed and properties of different active agents, so as to screen out the best concentration formula. The instrument is easy to operate, fully automatic measurement, direct reading, very suitable for quality control.
QWe do cosmetic emulsion, need to test Dispersion and Stability, what instrument to choose?
A The BZY200 plate method surface tensiometer is suitable. It can analyze the dispersion and wettability of emulsions by measuring surface tension, helping to evaluate the Stability of formulations. The instrument meets many international standards, the results are reliable, and with Touchscreen, it is easy to operate. It can save and print data for easy mass traceability.
QTo detect the oil-water interfacial tension of transformer oil, what are the requirements for the function of the instrument? Which one is recommended?
A Detecting transformer oil requires accurate measurement of oil-water interfacial tension to judge the purity and deterioration of the oil. Recommended BZY200, it uses both platinum plate method and ring method, especially suitable for interfacial tension testing of petroleum products. Measurement range, high accuracy, fully automatic operation, in line with relevant oil detection standards, can ensure accurate and reliable data.
QDoes the surface tensiometer say how much capacity is required?
A This type of surface tension detector, plate method measurement of at least 7mL sample, ring method measurement of 15mL.
QThe surface tension viscosity of the measured solution is relatively large Our solution can be about 10,000 cp.
A To ensure that the data is heavy and linear, the viscosity is recommended not to exceed 3000cP.
QThe general sample viscosity is relatively low, only a few hundred cp. Which method is used to test more?
A Generally, a plate surface tensiometer is used.
Knowledge
Standard