Measurement range of dissolved oxygen is 0.00~20.00mg/L, which can measure the pH value of the solution and display the temperature of the measured liquid. Dissolved oxygen Tester is widely used in industry, laboratory, agriculture, breeding, scientific research and environmental protection.
$175.00/set
PromotionLoading...
Coupon
Model:
Certificate

SMART SENSOR AR8210+ Pen dissolved oxygen instrumentSPEC

SMART SENSOR AR8210+ Pen dissolved oxygen instrumentDetails

SMART SENSOR AR8210+ Pen dissolved oxygen instrumentPacking list

SKU
NB038548
DO Measurement Range
0.00~20.00mg/L
DO intrinsic error
±0.4mg/L
Measurement response time
<30s
DO temperature compensation range
0~40℃
Tested solution temperature range
0℃~40℃
Ambient Temperature
0~40℃
Working Relative Humidity
≤85%RH
Self Adjustment
Yes.
screen display
Color screen display
Automatic temperature compensation function
Yes.
data retention function
Yes.
℃/° F unit conversion
Yes.
AR8210+
Pen dissolved oxygen instrument
Measurement range of dissolved oxygen is 0.00~20.00mg/L, which can measure the pH value of the solution and display the temperature of the measured liquid. Dissolved oxygen Tester is widely used in industry, laboratory, agriculture, breeding, scientific research and environmental protection.
SMART SENSOR AR8210 + Pen Dissolving Oxygen Meter (Lithium TV Color Screen) Picture

The pen type Dissolved Oxygen Meter produced by our company has high precision, stable, reliable and easy to carry. The product design is more professional, it can measure the dissolved oxygen value of water quality and display the temperature of the measured water quality. Pen-type Dissolved Oxygen Meter is widely used in agriculture, industry, aquatic products, medicine, laboratory, domestic (CN) water and other fields.

Smart Sensor AR8210+ Pen Type Dissolved Oxygen Meter Details Figure 1

Smart Sensor AR8210+ Pen Type Dissolved Oxygen Meter Details Figure 2

Instructions

The electrodes just shipped from the factory are in a dry state. Before use, the electrode filling solution needs to be added:

1. Remove the electrode membrane sleeve, add 3/4 of the electrode filling solution, and ensure that there are no air bubbles in the electrode membrane sleeve. If there are air bubbles, you can pinch the electrode film cover and tap it with your fingers, and the air bubbles will rise in the electrode film cover to remove the air bubbles.

2. Screw the electrode film cover that has been filled with electrode filling solution onto the electrode until it is tight. During the screw-in process, the film will gradually adhere to the surface of the gold cathode until it becomes flat. During the installation process, make sure that there are no small air bubbles in the cavity . Note: If the electrode filling solution spills, please wipe up the spilled filling solution.

3. Connect the electrode to the instrument, turn on the machine and polarize the electrode for 30 minutes before use. If the electrode is inserted into anaerobic water or saturated oxygen water, the value does not change much, then the electrode membrane sleeve and electrode filling solution should be replaced.

4. Calibration introduction

The instrument adopts two-point calibration, please prepare first - a cup of anaerobic water, and a cup of saturated oxygen-dissolved water ( see Appendix 1 for details on how to prepare anaerobic water and saturated oxygen-dissolved water). If the water sample to be tested contains a certain salinity (such as a seawater farm), the salinity setting should be carried out during measurement (the salinity value needs to be measured with a salinity meter), and the salinity setting range of this instrument is (0.0~45%o); Then, if you are not measuring at the corresponding sea level, you need to set the air pressure (atmospheric pressure needs to be measured by a barometer ). The instrument sets the atmospheric pressure range: (101. 3~79.9KPa or 760~600mmHg).


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.