YIHENG BPN-150CRH Co2 Incubator 155L/750W

SE
Volume 155L, 750W, RT + 5~ 55 ℃, gas sleeve type, CO2 control range 0~20%, 90 ℃ high temperature heating and humidity sterilizing, using imported infrared CO2 Sensors
$4352.00/set
PromotionLoading...
Coupon
Model:

YiHeng BPN-150CRH Co2 IncubatorSPEC

YiHeng BPN-150CRH Co2 IncubatorDetails

YiHeng BPN-150CRH Co2 IncubatorPacking list

SKU
NB038563
Power
AC220V/50HZ
Input power
750W
Heating method
Air jacket microcomputer PID control
Temperature range
RT+5~55°C
Environment temperature
+5~30℃
Temperature fluctuation
±0 1℃
CO2 range
0~20%
CO2 control Accuracy
+/- 0.1% (Infrared Sensors)
CO2 recovery time
(Open the door for 30 seconds to restore to 5%) ≤ 3 minutes
temperature recovery
(Open the door for 30 seconds and return to 37 ℃) ≤ 8 minutes
Relative Humidity
Natural evaporation ≥ 90% (can be equipped with Relative Humidity digital display)
Volume
155L
Liner size
480×530×610mm
Dimensions
670×767×880mm
Shelf (std.)
3 pieces
90 ℃ high temperature heating and humidity sterilizing
Yes.
BPN-150CRH
Co2 Incubator
Volume 155L, 750W, RT + 5~ 55 ℃, gas sleeve type, CO2 control range 0~20%, 90 ℃ high temperature heating and humidity sterilizing, using imported infrared CO2 Sensors
YIHENG BPN-150CRH Co2 Incubator 155L/750W Picture

The new generation of carbon dioxide Incubator, based on the company's more than ten years of design and manufacturing experience, always takes the needs of customers as the guide, constantly researches new technologies, and applies them to products, representing the development trend of carbon dioxide Incubators. Imported infrared CO2 sensor is used, the control accuracy is accurate and stable, and it is not affected by temperature and humidity.

Yiheng BPN-150CRH carbon dioxide Incubator details Figure 1

Features

◆Faster recovery speed of CO2 concentration

● If the door of the chamber needs to be opened frequently during the experiment, the infrared sensor is a suitable choice.

● Imported infrared (IR) sensor has the ability to monitor carbon dioxide gas quickly and is not affected by external temperature and humidity fluctuations

And other features, such as closing the door after opening the door for 30 seconds, it can return to 37°C in less than 10 minutes, and return to 5% of the set CO 2 concentration in less than 5 minutes, even when multiple people use it and need to open and close the door frequently , can still keep the CO2 concentration in the box stable and uniform. The thermal conductivity sensor is easily affected by temperature and humidity, and has long response time and large detection error. If it is used for a long time, it needs to be calibrated frequently.


◆Effective microbial filter

●The CO2 air inlet is equipped with an effective microbial filter, which has a filtration efficiency of 99.99% for particles with a diameter greater than or equal to 0.3 μm, effectively filtering bacteria and dust particles in the CO2 gas.

◆Door heating system

● The door of the CO2 Incubator can heat the inner glass door, which can effectively prevent the glass door from condensing water and prevent the possibility of microbial contamination caused by the glass door condensing water.

◆Circulation fan speed automatic control

● The speed of the circulating fan can be automatically controlled. When the temperature inside the box is at a constant temperature, the speed will decrease and the circulating air speed will increase.

Adjust the wind speed suitable for cell growth to avoid volatilization of the sample due to excessive wind volume during the test.


◆HEPA effective filter

● It can effectively filter out bacteria and dust particles in the outside air, eliminate and prevent cross-contamination between the outside air and the inner chamber of the Incubator, and keep the inside of the Incubator in a sterile state.

● 5 minutes after the door is closed, the air quality in the box can be restored to the 100-class clean level.

● The effective HEPA filter is easy to assemble and disassemble without tools.


◆Humanized design

● It can be stacked (on the second floor) to make full use of the laboratory space. The large-screen LCD above the outer door can display temperature , CO2 concentration and Relative Humidity. The menu-based operation interface is easy to understand and easy to observe and use.


◆Security function

● Independent temperature limit alarm system, which can prompt the operator with sound and light alarm, to ensure the safe operation of the experiment without accidents.

● With low temperature, high and over temperature alarm, CO 2 concentration is too high or too low alarm.

● Equipped with security facilities such as an alarm for too long door opening time and a reminder of the working status of ultraviolet sterilization.


    microcomputer controller

    Large-screen LCD display, controlled by microcomputer PID, can simultaneously display temperature, CO2 concentration, Relative Humidity and operation, fault prompts, and menu-style operation is easy to understand and easy to observe and use. 

    90°C High Temperature Humid Heat Sterilization System

    It can effectively sterilize the inner chamber (including temperature sensor, carbon dioxide concentration sensor, fan , partition and bracket) with high temperature and humidity, and effectively eliminate bacteria, mold, mycoplasma and other microorganisms caused by cell culture. Pollution, to provide users with a safe experimental environment.

    Data recording and fault diagnosis display (optional)

    All data can be downloaded to the computer through the RS485 port for storage, and when a fault occurs, the data can be retrieved from the computer and diagnosed in time.

Series

modelBPN-40CRHBPN-80CRHBPN-150CRHBPN-190CRHBPN-240CRHBPN-500CRH
VoltageAC220V/50HZ
input power350W500W750W750W950W1450W
heating methodAir jacket microcomputer PID control
Temperature control rangeRT+5~55℃
Working temperature+5~30℃
temperature fluctuation±0 1°C
CO2 control range0~20%
CO2 control accuracy±0.1% (infrared sensor)
CO2 recovery time(Open the door for 30 seconds to recover to 5%) ≤ 3 minutes
temperature recovery(Open the door for 30 seconds to return to 37°C) ≤ 8 minutes
Relative HumidityNatural evaporation ≥ 90% (can be equipped with digital display of Relative Humidity)
volume40L80L155L119L240L500L
Inner tank size (mm) W×D×H400×286×350400×450×500480×530×610520×530×690600×630×670700*650*1100
Dimensions(mm)W×D×H590×440×576590×687×790670×767×880708×710×1030788×837×940880*860*1500
Carrier (standard)2 blocks3 pieces
90°C High Temperature Humid Heat Sterilizationhave

optional parts

1. RS485/232 interface and communication software

2. Special carbon dioxide pressure reducing valve

3. Humidity display system

4. Wireless alarm system (SMS alarm system)


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.