China

Pingxuan BZY-1 Automatic Surface Tensiometer accuracy 0.1mN/m Range 400mN/m

SE
Accuracy 0.1mN/m, range 400mN/m, platinum plate, platinum ring two test methods, automatic measurement, full scale one key to clear, full scale auto calibration, accuracy automatic correction, temperature automatic compensation.
$2993.00/set
PromotionLoading...
Coupon
Model:
Certificate

PingXuan BZY-1 Automatic Surface TensiometerSPEC

PingXuan BZY-1 Automatic Surface TensiometerDetails

PingXuan BZY-1 Automatic Surface TensiometerPacking list

SKU
NB038929
Measurement method
Platinum plate, ring method (choose one of the two)
Surface tension Measurement range
0~400mN/m
Operation mode
Automatic lifting, automatic measurement
Data Display
Surface/interfacial tension (platinum plate method)
Display
Wide Viewing Angle backlit LCD, digital display
One-click zero range
0~400mN/m
sensitivity
0.1mN/m
Accuracy
0.1mN/m
Sexual repeability
0.1mN/m
Full scale auto calibration
automatic
Accuracy auto calibration
Yes.
Automatic temperature compensation
Yes.
Data Interface
RS232
data processing software
match
Test time
Low concentration samples: 3-5 seconds for platinum plate method, 40-60 seconds for platinum ring method
BZY-1
Automatic Surface Tensiometer
Accuracy 0.1mN/m, range 400mN/m, platinum plate, platinum ring two test methods, automatic measurement, full scale one key to clear, full scale auto calibration, accuracy automatic correction, temperature automatic compensation.
Pingxuan BZY-1 Automatic Surface Tensiometer accuracy 0.1mN/m Range 400mN/m Picture

Introduction

Professional research and development and production of BZY series automatic surface/interface tensiometer, with reference to the advantages of the same type of instruments currently available at home and abroad, the original BZY series automatic Surface Tensiometer has been fully upgraded and improved, and a number of new technologies have been adopted. The technical level and performance of the domestic (CN) automatic surface/interfacial tensiometer have reached a new height.

Features

Both platinum plate and platinum ring test methods are used together, fully automatic measurement, full range one-key reset, full range automatic calibration, automatic accuracy correction, and automatic temperature compensation. Sample temperature control, multi-function data processing software. The instrument has accurate measurement, excellent repeatability, professional technology and excellent performance.

Advantages

① Using international professional sensor technology, it has higher precision, better repeatability and better stability;  

② When using the platinum ring test method, the peak value automatic hold function is added to eliminate human error and the measured value is more accurate;  

③ Successfully developed the company's unique accuracy automatic calibration function, using distilled water and ethanol to calibrate the overall test accuracy of the instrument, which can ensure that the instrument is in the accurate state when it leaves the factory for a long time;  

④ Successfully developed the company's unique temperature automatic compensation function, so that the user's measurement data at different temperatures can be uniformly corrected to the test state at 20°C;  

⑤ The control and processing procedures of the hardware part of the instrument have been enhanced and optimized, and the performance is superior;  

⑥ Successfully developed the data processing software for the automatic Surface Tensiometer/interfacial tensiometer: it can automatically collect test data, display the test curve in real time, and the curve can be automatically enlarged, stored and printed. Can compare multiple curves, the original data can be converted into an Excel file, and can automatically calculate the surface tension value when using the platinum ring test method; 

⑦ Adopt international professional lifting platform drive technology, no vibration and noise 

main feature

1. Platinum plate method;  

2. When the platinum plate is tested, the displayed value is the surface tension value; 

3. When using the platinum ring test method, the displayed value automatically locks the maximum force value of the sample, and then calculates the surface/interfacial tension value through the included calculation software or selects the data processing software to be automatically calculated by the computer; 

4. Platinum ring size: the wire radius is 0.185mm, the ring radius is 9.55mm, and the ring circumference is 60mm; 

5. When using the platinum ring test method, it fully complies with the following domestic (CN) and international standards:  

GB/T 22237-2008 Determination of Surface Tension of Surfactants  

JB/T 9388 -2002 Technical Conditions for Interfacial Tensiometer  

JB/T 18396-2001 Determination of surface tension by natural latex ring method  

SH/T 1156-95 Determination of surface tension of synthetic latex  

GB/T 6541 - 86 Determination of interfacial tension between oil and water of petroleum products (ring method)  

ISO 1409-1995 Determination of surface tension of plastics, rubber, polymer dispersions and latex  

ISO 6295-1983 Determination of interfacial tension of petroleum products, mineral oil and oil on water (ring method)  

GB/T 5549 (ISO304-1985) Determination of Surface Tension by Pull-up Film Method  

And ISO14090-82, ASTM D1417, EN14370, ZB2025-93, GB2960-82, GB6541-86 and other standards;

6. Fully automatic measurement to avoid human error; 

7. Full-scale automatic calibration, accurate and reliable data, excellent repeatability; 

8. One-button zero reset of the full range, which is completed instantly, and the zero position is stable without drift; 

9. Adopt international professional lifting platform drive technology, no vibration and noise; 

10. The instrument has a reasonable structure and works independently without any additional equipment (such as an external computer, etc.), and can also be equipped with a computer for data processing; 

11. When using a platinum plate, it can measure the surface tension or interfacial tension of the liquid in real time. It is very practical for measuring samples containing surfactants or volatile substances whose surface tension will change with time (select data processing software , the test curve can be displayed in real time, and the details of the tension change can be obtained); 

12. When using platinum plate to test, it can automatically test the surface tension of medium and high viscosity liquid samples; 

13. The two test methods can measure the interfacial tension between immiscible liquids such as: oil/water interface;     

14. Data processing software (option): It can automatically collect test data, display test curves in real time, and the curves can be automatically enlarged, stored and printed. Can compare multiple curves, the original data can be converted into an Excel file, and can automatically calculate the surface tension value when using the platinum ring test method;  

15. Accuracy calibration function (option): With twice distilled water and pure ethanol as the standard, the overall test error of the instrument is automatically calibrated, which can ensure that the instrument is in the accurate state when it leaves the factory for a long time;  

16. Automatic temperature compensation function (option): with twice distilled water and pure ethanol as the standard, it automatically summarizes the test values at 20°C for samples at different temperatures;   

17. A variety of temperature control options are attached to meet different test requirements;  

18. Meet the special requirements of users and undertake non-standard products. 

FAQ
QI want to measure the surface tension, how does the BZY-1 instrument work?
A This BZY-1 fully automatic surface tensiometer can be used in both platinum plate and platinum ring test methods, and it is fully automatic measurement. You only need one button operation, the instrument can automatically complete the calibrate, clear and test, greatly reducing human error. Its accuracy is very high, Repeatability is also very good, and it also has automatic temperature compensation to ensure that the data you measure at different temperatures are uniformly corrected to the standard state of 20 ° C.
QOur laboratory mainly does oil and surfactant analysis. Is this instrument suitable?
A Suitable. The design of BZY-1 fully complies with the testing standards of the oil and surfactant industry, such as the national standard GB/T 6541 and international standard ISO 6295 for measuring oil-water interfacial tension, and the GB/T 22237 for measuring surfactant surface tension. Especially when it uses the platinum plate method, it can display the tension value in real time. It is especially practical for samples where the tension of surfactants changes over time. The software can also record changes Linear dispersion. There is no problem in measuring oil-water interfacial tension.
QIt says there are two test methods, platinum plate method and platinum ring method, how should I choose?
A Which method to choose mainly depends on your sample and needs. If the viscosity of the sample you measure is not high, such as common aqueous solutions, surfactants, or you need to get results quickly, it is recommended to use the platinum plate method, which is fast to test, and the displayed value is directly the tension value, which is easier to operate. If the viscosity of the sample you measure is relatively high, or you need to use the ring method in strict accordance with some historical standards (such as some old national standards or industry standards), then choose the platinum ring method. The advantage of BZY-1 is that both methods are integrated into one instrument, and you can switch flexibly according to the experiment, which is very convenient.
QIs the ring method accurate for measuring oil-water interfacial tension?
A Yes, the platinum ring method of BZY-1 fully complies with the national standard of interfacial tension of petroleum products, and also has the function of automatic peak hold, which can eliminate human error and the oil-water interface is very reliable.
QWill the instrument be inaccurate after being used for a long time? How to maintain it?
A Don't worry, this one has an automatic correction function, regularly calibrate with distillation water and ethanol, and automatically compensate for temperature to ensure that the data is always accurate and maintenance is particularly worry-free.
QHow does the temperature of the liquid affect the automatic surface tension measurement?
A Temperature can significantly affect the surface tension of the liquid, so it is often necessary to stabilize the liquid temperature at the set value before measurement, and record and control the temperature change in the measurement.