- SKU
- NB039065
- Display mode
- digital explicit
- Measurement range
- 0.608~30380mPa·s
- Rotor speed
- 0.1~100rpm
- Reproducibility
- ±0.2%F.S
- Measurement Accuracy
- ±1%F.S
- measurement mode
- Manual, automatic stop time, automatic viscosity stop mode, programming mode (up to 40 segments)
- Measurement Mode Storage
- 10 of the above measurement modes
- Measuring unit
- %/mPa·s/Pa·s/kPa·s/ (真 つ cP/P)
- Measuring temperature
- 10~60℃
- input and output model
- USB A terminal (for connecting serial printer), USB B terminal (for connecting PC), for connecting temperature sensor (optional), external connection terminal (measurement start/end signal)
- Temperature Resolution
- 0.1℃
- Temperature Accuracy
- ±0.2℃
- Zero Setting
- Yes.
- Range setting
- Yes.
- Environmental temperature
- 0~40℃
- Environmental humidity
- Relative Humidity less than 90% (no condensation)
- Power
- AC100~230v 50/60Hz (the limit load of the standard power cord is AC125V)
- current consumption
- 15VA
- Host size
- W300*334*436mm
- Weight
- About 6.5kg (including base bracket), base bracket about 2.4kg
- third gear
- M、2.5M、5M
- Full scale torque
- 67.37μN·m、168.4μN·m、336.9μN·m
- Segmented range of different gears
- 0.608~6076mPa·s、1.52~15190mPa·s、3.04~30380mPa·s、0.608~30380mPa·s
- Rotation speed Control mode
- Progressive growth of 0.1RPM, a total of 1001 segments
TV-200EL
Viscometer
M/2.5M/5M three-speed range, touch screen operation, viscosity range 0.608~ 30380mPa · s, servo motor, automatic range selection, program control.
Introduction
TV-200 viscometer adopts torque balance: servo technology to achieve multi-range measurement functions. Linearity and reproducibility of machine viscosity determination are guaranteed even within a wide measuring range. Has automatic range selection function. There is no need to worry about the measurement range of the sample. Thus effectively measuring viscosity.
Features
program functions;
Multi-range measurement; automatic range selection;
Data between multiple devices can be referenced;
4.3-inch color touch screen can display more experimental data.
TV-200 series model parameter range

Packing list:Viscometer x1, standard tapered rotor x1, sample cup x1, sample cup placement table x1, bottom seat bracket x1, main unit storage box x1, tapered rotor storage box x1, instruction manual x1.
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.