China

YIHENG GRX-9073A Laboratory Hot Air Sterilizer, LCD Power 1550W

SE
High-precision temperature control (RT + 10~200 ℃/RT + 10~250 ℃, 0.1 ℃ Temperature resolution , +/- 1 ℃ Temperature Fluctuation), energy saving and high efficiency (1550W), moderate Interior size (400 * 450 * 450mm), flexible Timer Range (1~ 9999 minutes) and compact design (740 * 590 * 630mm) are the selling points, suitable for various Environmental temperatures (5~ 40 ℃), and equipped with 2 shelves.
$689.00/set
PromotionLoading...
Coupon
Model:

YiHeng GRX-9073A Hot air sterilizerSPEC

YiHeng GRX-9073A Hot air sterilizerDetails

YiHeng GRX-9073A Hot air sterilizerPacking list

SKU
NB004028
Power
AC 220V 50Hz
Temperature range
RT+10~200°C/RT+10~250°C
Temperature Resolution
0.1℃
Environment temperature
5~40℃
Input power
1550W
Interior size
400*450*450mm
Dimensions
740*590*630mm
Shelf (std.)
2pcs
Timer
1~9999min
Temperature fluctuation
±1℃
Net Weight
49kg
Gross Weight
60Kg
Packing size
830*690*780mm
GRX-9073A
Hot air sterilizer
High-precision temperature control (RT + 10~200 ℃/RT + 10~250 ℃, 0.1 ℃ Temperature resolution , +/- 1 ℃ Temperature Fluctuation), energy saving and high efficiency (1550W), moderate Interior size (400 * 450 * 450mm), flexible Timer Range (1~ 9999 minutes) and compact design (740 * 590 * 630mm) are the selling points, suitable for various Environmental temperatures (5~ 40 ℃), and equipped with 2 shelves.
YIHENG GRX-9073A Laboratory Hot Air Sterilizer, LCD Power 1550W Picture

Introduction of GRX-9073A laboratory hot air disinfection box

Yiheng GRX-9073A laboratory hot air disinfection box is a hot air disinfection box that uses high-temperature dry heat heating to eliminate microorganisms. The input power of GRX-9073A is 1550W, and the temperature control range is RT+10~250℃.

Applications

GRX-9073A laboratory hot air disinfection box uses high temperature and dry heat to oxidize microorganisms, denature proteins, and cause poisoning caused by dielectric concentration. Among them, the protoplasm of cells is mainly destroyed by oxidation, and microorganisms are killed, so all microorganisms can be killed within a certain heating time.

Features and advantages

1. Accurate: High-precision microcomputer liquid crystal display temperature controller, accurate and reliable temperature control. ,

2. Safety: If the temperature exceeds the limit, it will be automatically interrupted to ensure the safety of personnel and instruments.

3. Rapid: rapid heating, forced convection, hot and dry air directly passes through the heated object, and the drying and disinfection time is significantly shortened.

4. Convenience: The three speeds of the fan can be adjusted from the instrument settings, Timer Control, and the shelf can be moved to facilitate cleaning in the box, making the operator feel convenient everywhere.

Pictures

Real shot of Yiheng GRX-9073A laboratory hot air disinfection box