Measurement parameters
COD, total phosphorus, turbidity, suspended solids
measurement error
≤± 5%
Repeatability
≤±5%
Optical inspection Stability
≤ +/- 0.001A/20min (100,000 hours life)
Data storage
3万条记录(包括项目、日期、时间、样品ID等)
Linear dispersion quantity
96 Linear dispersions (expandable)
printer
Built-in thermal printer
Display
5-Inch high-definition color LCD
batch Volume
16/25 water samples/batch
Colorimetric method
Digestion Colorimetric Tube
Sample compatibility
16 mm (round), 25mm (round)
Communication interface
USB cable, LAN, etc
exception notification
Blank comparison prompt, overrange prompt, etc
Operating interface
Membrane push-button operation, Chinese/English (optional)
Power Supply
AC(220V±10%),50Hz
Power
5W
Protection level
IP30
Relative Humidity
≤ 85% non-condensing
Ambient Temperature
5~40℃
Host size
348*250*145mm
Instrument Weight
Main unit less than 2.6kg
COD detection method
Method 1: HJ/T399-2007 standard; Method 2: Import detection method
COD Measurement range
0-10000mg/L;0-15000mg/L
Lower limit of COD detection
3 mg/L;2 mg/L
COD digestion environment
165℃,15min;165℃,20min
COD anti-chlorine interference
1000 mg/L (expandable); 1000 mg/L (expandable)
Total phosphorus detection method
GB11893-89
Total Phosphorus range
0~20mg/L
Total phosphorus detection limit
0.01mg/L
Total Phosphorus Digestion
125℃,30min
Turbidity detection method
Spectrophotometric method, spec-trophotometry
Turbidity Measurement range
0 ~ 1000NTU
Lower turbidity detection limit
0.5NTU
Turbidity digestion environment
No need to digest
Suspended solids detection method
Direct Colorimetry
Measurement range of suspended solids
0~500mg/L
Lower limit of suspended solids detection
2mg/L
Suspended solids digestion environment
No need to digest
TR 6900CP
Desktop STIP-scan
At the same time, the content of COD, Total phosphorus, turbidity and suspended solids (SS) in the water was detected, which met the standards. The built-in thermal printer was used, and the digestion Colorimetric integrated tube Colorimetric was used.
TONGAO TR 6900CP Benchtop STIP-scan detection of COD/Total phosphorus/turbidity/suspended solids (SS) Picture

Introduction

The instrument can quickly measure COD, Total phosphorus, turbidity, suspended solids, etc. in various water qualities. It integrates mature technologies in the field of water quality analysis to make the entire analysis system more complete, the operation is simpler and faster, and the detection results are more stable and reliable. Widely used in emergency monitoring, industrial wastewater, domestic (CN) sewage, sewage treatment, pharmaceutical and chemical industry, food, beverage, textile printing and dyeing, electroplating, papermaking, petroleum metallurgy, river management, scientific research units, colleges and universities and other fields.

operating principle

The integrated digestion colorimetric tube and the multi-channel water quality rapid analyzer can be used seamlessly, and are compatible with φ25mm colorimetric tubes.Tongao Technology TR 6900CP Desktop Water Quality Detector Details Figure 1

● The detection of each parameter conforms to national standards, industry standards or international standards.

●  Built-in two COD detection methods

Method 1: HJ/T399-2007 (national standard)

Method 2: Import detection method

●  The standard detection parameters are as follows:

- COD (premade reagents)

- COD (powder pack reagent or custom reagent)

- Total phosphorus (TP)   

- Turbidity - Suspended Solids (SS)

●  Strong scalability in the later stage, including but not limited to the following parameters:

- Ammonia nitrogen - CODmn

- Total Nitrogen - Phosphate

- Total chromium - Hexavalent chromium

- copper - iron

- Nickel - Zinc

- Nitrite ...

Principle

1. Digestion colorimetric integrated tube

The digestion and colorimetric integrated tube is used for operation, and the digestion of the sample and the reading of the result share a reaction tube, and there is no need to transfer the liquid to the cuvette for detection.

2. Display the result directly

A cold light source with a specific wavelength is used to measure the absorbance of the sample, and the instrument system converts the detection result directly into the sample concentration value through a specific algorithm. 

3. Measure multiple times and remove outliers

Measure the water sample 10 times or more, and take the average value after removing outliers, so as to reduce the influence of dirt, scratches, fingerprints or defective glass tubes on the results.

4. Detection of abnormal prompts

Prompts for abnormal detection, such as prompts for blank comparison, prompts for results exceeding the upper limit of the range, etc.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Knowledge
Standard