This series of thermal shock testing machine is mainly used to test the resistance of materials to extremely high or low temperatures, which is similar to the situation of discontinuous high or low temperatures, and the thermal shock test can make various items complete the test in the shortest time. The changes or physical injuries caused by thermal shocks are caused by changes in thermal expansion and contraction or other physical values, and all kinds of products can be fully trusted by using the PID system. The effects of thermal shock include electrochemical changes caused by cracking or breaking layers and displacement of the finished product, and the full digital element automatic control of the PID system will make it easy for you to operate.
Thermal shock testing machine is widely used in electronic and electrical components, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, national defense industry, aerospace, military industry, BGA, PCB base wrench, electronic chip IC, semiconductor ceramic and polymer materials physical changes, testing the repeated tensile force of the material to high-low temperature and the chemical change or physical damage of the product in thermal expansion and contraction, can confirm the quality of the product. From precision ICs to heavy machinery components, it can be used as the basis or reference for the improvement of its products.
1. GB/T2423.1-2001 low temperature test method;
2、GB/T2423.2-2001;
3. GB/T2423.22-1989 temperature change test N;
4. National military standard GJB150.3-86;
5. National military standard GJB150.4-86;
6. National military standard GJB150.5-86;
7. GJB150.5-86 temperature shock test;
8. GJB360.7-87 temperature shock test;
9. GJB367.2-87 405 temperature shock test;
10. SJ/T10187-91Y73 series temperature change Test Chamber - one box;
11. SJ/T10186-91Y73 series temperature change Test Chamber - two-chamber type;
12. Meet the standard IEC68-2-14_ test method N_ temperature change;
13. GB/T 2424.13-2002 Test Method Temperature Change Test Guidelines;
14. GB/T 2423.22-2002 temperature change;
15 QC/T17-92 General rules for weather resistance test of auto parts;
16. EIA 364-32 Environmental Impact Assessment of Electrical Connectors and Receptacles for Thermal Shock (Temperature Cycling) Test Procedures.
1. Operating Principle:Three-Chamber type, product static test mode
2. Condensation method:Air-cooled and power-saving ultra-low temperature refrigeration system (air-cooled heat dissipation method)
3. Refrigeration compressor:French Taikang high-horsepower mechanical compressor
4. Evaporator:Fin heat exchanger (doubles as a dehumidifier)
5. Throttling device:Electronic expansion valves
6. Evaporative condenser:Brazed plate heat exchanger
7. Chiller control mode
The control system automatically adjusts the chiller according to the test conditions for better operation
Energy-saving conditions
Compressor return air cooling circuit
Energy regulation loops
8. Digital display of refrigeration system Operating Conditions
Evaporative pressure regulating valve
The controller digitally displays the high-low pressure pressure, exhaust temperature and compressor operating current of the refrigeration system
9. Refrigerant:R404a/R23 (both ozone depletion index 0)
10. Others: The main components are all international good brand products
Heater: nickel-chromium alloy heating wire heater;Heater control mode: Constant periodic pulse width adjustment without contact, SSR (Solid State Relay)
Controller model: Korean TIMI8226
The product uses computer technology, excellent PID control method to measure and control the ambient temperature, and can be used with thermal shock test equipment.
★ The display and control interface is intuitive and clear, and the touch selection menu is easy to use, and the performance is stable and reliable.
★ Effective, flexible program control, to bring users stable performance, flexible control, cost-effective high-end products.
★Program editing: There are three types of programs, namely 2ZONE, 3ZONE, and STEP
Category 1 is 2ZONE, which can edit 120 programs, each with only 2 segments
Category 2 is 3ZONE, which can edit 120 programs, each with only 3 segments
Category 3 is STEP, which can edit 120 programs with a maximum of 20 segments per program
Range: The program can be linked (the serial number of the linked program can be selected)
Temperature: Adjusted according to the temperature operating range of the device (upper limit +5°C, lower limit -5°C)
Display Resolution:Temperature: 0.01°C;Time: 0.01min
Input:thermocouple
Communication function (optional):RS-232 converter
Curve recording function:RAM with battery protection to save the device's setpoint, sample value and time of sampling time, with a maximum recording time of 350 days (when the sampling period is 1.5 minutes)
1) Door: Hinged door, door hinge on the left side of the box (when facing the front of the box)Door distribution heating (automatic adjustment) Anti-frost, anti-condensation insulating glass observation window(W210×H320mm) a;
The door frame is equipped with electric heating (automatic adjustment) anti-frost and anti-condensation device;Interior light on the door (effective long-life LED light source)
2) Control Panel: Controller Display,Operation button, over-temperature protection setting device
3) Mechanical room machine:Included in the machinery roomRefrigeration units, drainage devices, fans, distribution control cabinets
4) Power distribution control cabinet:Cooling fan,buzzerSwitchboards
Compressor high-low pressure overpressure protection
Compressor motor overheating protection
Compressor motor overcurrent protection
Frozen oil pressure liquid mirror
Refrigerant high-low pressure gauge
Adjustable over-temperature protection
Test space temperature fuse filament
The air conditioning channel is overheated at the limit
The fan motor is overheated
Air pressure balance device inside and outside the box
When the box door is opened (in operation), it prompts an alarm
1) Power Cable:1 x 5-core cable (4-core cable + protective grounding wire) (6 m long)
2) Specimen power control terminal
Total power leakage circuit breaker
Relay contact control, within AC380V, 20A (when normal operation, the contact is closed;
When the equipment is shut down or malfunctioning, the contacts are disconnected)
It is strongly recommended that users use the control terminal to control the power on and off of the test sample to ensure that
In the event of a machine failure or shutdown, the circuits connected to the test specimen are reliably cut off
3) Materials: Provide Chinese version of user manuals and technical materials
4) Transportation: The main structure of the Test Chamber is integral
5) Conditions of Use:The user warrants the following conditions
6)venue
The floor is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust
There are no sources of strong electromagnetic radiation in the vicinity
Drain floor drain near the equipment (within 2 meters from the refrigeration unit)
Site ground load capacity: not less than 800kg/m2 Leave appropriate maintenance space around the equipment
7) Environmental conditions
Temperature: +5°C~+35°C
Relative Humidity: ≤ 85%RH
Air pressure: 86 kPa~106kPa
8) Power supply
AC (380±10)V (50±0.5)Hz three-phase four-wire + PGD
The grounding resistance of the protective ground wire is less than 4Ω, and the power supply is supplied by TN-S mode or TT mode
The user is required to configure the equipment with an air or power switch of the appropriate capacity at the installation site, andThis switch needs to be stand-alone and dedicated for use by this device
9) Power Capacity:21kw
10) Requirements for the storage environment
When the equipment is not working, the temperature of the environment should be kept within 0~+45°C (no freezing).
When the ambient temperature is lower than 0°C, the water remaining in the equipment should be discharged to avoid pipes
The water inside freezes and swells the pipes