China

HUDA laboratory Humidity Chamber QT-E702-225K70 -70 ℃/225L

Temperature control -70 ℃, Content volume 225L, Cold rolled steel plate Baking paint Appearance, Ultra-low temperature laboratory use, heating and humidification system is completely independent, touch screen control, non-standard customization, in line with JJF1101-2003 standard.
Certificate

HUDA QT-E702-225K70 Programmable Humidity ChamberSPEC

HUDA QT-E702-225K70 Programmable Humidity ChamberDetails

HUDA QT-E702-225K70 Programmable Humidity ChamberPacking list

SKU
NB041380
Interior Volume
225L
Temperature range
-70~150℃
Temperature Resolution
0.01℃
Temperature Fluctuation
≤±0.5℃
Temperature Uniformity
±2℃
Humidity control range
20~98%R.H
Humidity Deviation
±2%R.H
Humidity stability
±2%R.H
Humidity Uniformity
±3%R.H
Interior size
500*750*600mm
Dimensions
780mm×1680mm×1520mm
Temperature deviation
≤±2℃
Humidity resolution
0.1%R.H
Temperature control Accuracy
±0.01℃
Humidity Control Accuracy
±0.1%R.H
Heating rate
≧3℃/min
Cooling rate
≧1℃/min
Refrigeration system
2 * 0.75HP imported French Taikang fully enclosed compressor
refrigerant
Environmentally friendly refrigerant R404/R23/freezing oil
Refrigeration system
Mechanical binary refrigeration method
Wind circulation
Centrifugal fan with forced circulation
Condenser
finned tube heat exchanger
Condensation method
air-cooled
Condenser
Stainless steel brazed plate heat exchanger
Humidification system
Stainless steel humidifier
Heating system
Nickel chromium alloy stainless steel heating device
water supply system
Front-mounted water supply tank, fully automatic water supply system
Controller
Taiwan, China Youyi Controller
setting method
Chinese/English interface, touch input
operation mode
Program method/valuation method
setting range
Maximum temperature range 5 ℃
Display resolution
Temperature: 0.01 ℃; Time: 0.1 min
Power-off memory function
The power failure recovery mode can be set as: hot start/cold start/stop
input
platinum resistance
storage function
Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand storage
Safety Devices
overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc
Software Operating Environment
IBM PC compatible computer, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system
Enclosure Material
Cold rolled steel plate (1.0mm thick)
Chamber material
SUS #304 mirror stainless steel (1mm thick)
Insulation material
100Mm polyurethane rigid foam + 100mm high density fiberglass cotton
Weight
283kg
Rated current
22A
Rated power
11kw
Power
380V
test hole
50mm
program amount
Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments
Communication interface
1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system
QT-E702-225K70
Programmable Humidity Chamber
Temperature control -70 ℃, Content volume 225L, Cold rolled steel plate Baking paint Appearance, Ultra-low temperature laboratory use, heating and humidification system is completely independent, touch screen control, non-standard customization, in line with JJF1101-2003 standard.
HUDA laboratory Humidity Chamber QT-E702-225K70 -70 ℃/225L Picture

Introduction

This series of constant temperature and humidity testing machines are mainly used to simulate the harsh high-low temperatures that electronic instruments, new materials, electricians, vehicles, metals, electronic products, aerospace materials, etc. may encounter during transportation, storage, and use. Or in a hot and humid environment; or in an environment of alternating high temperature, low temperature, and humid heat, test the resistance of materials, accessories, or equipment to high temperature, cold resistance, heat and humidity, and possible damage and shortened lifespan.

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 1

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 2

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 3

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 4

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 5

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 6

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 7

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 8

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 9

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 10

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 11

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 12

Hiyoda QT-E702-225K70 programmable constant temperature and Humidity Test Chamber details Figure 13

Features

(1) Box structure:

1. Inner box material: Made of SUS304# (1.0mm thick) stainless steel plate, which has the advantages of acid resistance, corrosion resistance, and easy cleaning.

2. Enclosure Material: cold-rolled steel plate, painted, 1.0mm thick (box body dark gray, door sky blue).

3. Door handle: It adopts non-reaction and explosion-proof door handle, which is easy to operate, safe and reliable.

4. Insulation system: Ultra-fine glass fiber is used to fill the insulation area, and the connection parts of the inner and outer boxes are made of non-metallic high-low temperature resistant materials to effectively reduce temperature conduction; the door seal is made of refined silicone rubber, so there is no aging under high-low temperature conditions. and hardening phenomenon, the sealing is more reliable; the humidification method adopts isolated humidification.

5. Moving and positioning device: High-quality fixed PU movable wheels are installed at the bottom of the machine, which can easily move the machine to a designated position and then fix the casters.

6. Sample rack: It is made of SUS304# stainless steel punched and bent into a mesh shape. It is easy to use. The spacing between the material racks is adjustable. There are two pieces in the standard configuration. The samples are evenly distributed according to the load-bearing ≧20kg.

7. Test hole: Open a Φ50mm test hole, and attach corresponding thermal insulation accessories and special sealing plugs

8. Observation window: It adopts double-layer vacuum-strengthened glass, and the inner glued conductive film is heated and defrosted to clearly observe the test process.

(2) Refrigeration system:

1. The refrigeration unit uses French Taikang compressors and American DuPont environmentally friendly refrigerant (R404a). It adopts a binary low-temperature circuit system design to facilitate the use of different compressors in different temperature ranges to increase equipment.

2. Temperature and humidity control adopts PID + SSR system co-channel coordinated control, with automatic calculation function, which can immediately correct temperature and humidity changing conditions, making temperature and humidity control more accurate and stable.

3. Both temperature and humidity adopt high-precision controllers, and the relative temperature and humidity performance can be accurately set and displayed with a resolution of 0.1℃.

(3) Heating and humidification system:

1. Heating uses nickel-chromium alloy high-speed heating electric wire; 

2. High temperature completely independent system; 

3. The humidity adopts stainless steel tube with built-in nickel-chromium alloy high-speed heating wire and high-temperature magnesium oxide powder, which has fast response and long life. 

4. The heating and humidification systems are completely independent, and the humidity has an automatic water replenishing device.

(4) Control system:

1. Adopt precision LCD display programmable temperature controller; 

2. Intelligent digital display PID microcomputer temperature control instrument; 

3. Touch setting, digital and direct display, the humidity directly displays the percentage, and the temperature sensor uses a PT100 platinum resistance Tester. 

4. Temperature control adopts thermal balance temperature regulation method. 

5. The precision liquid crystal display programmable temperature controller can be used for program testing. It can have multiple groups of multi-stage programming operations, optional fixed values ​​and programs, and the function of setting the time arbitrarily. 

6. The main electrical components of the equipment, such as circuit breakers and AC contactors, are all of the "CHINT" brand, and other electrical accessories are of familiar domestic (CN) brands. 

7. Convenient data processing: It can be connected to a printer or 232 communication interface, and has a USB data transfer interface (U disk). It can be displayed on a computer and print temperature, humidity and time curves, providing a strong guarantee for data storage and playback during the test process.

(5) Protection system:

Overall equipment overtemperature, fan overheating protection, overall equipment phase loss/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment timing, and other protections such as leakage, operating instructions, automatic shutdown after fault alarm, etc.

Test Standard

1.GB2423.1-2008/IEC6008-2-1-2007

2. GB/T 2423.2-2008

3. GJB150.3A-2009

4. GJB150.4A-2009

5. GB2423.22-2008

6.GBT 2424.5-2006

7. GB/T 10589-2008

8. GB/T2423.3-2008(IEC68-2-3)

FAQ
QIsn't this water addition directly connected to an external faucet? Is there any difference between the automatic water replenishment for billing?
A If you don't need to do experiments often, you can manually add purified water, because tap water has many impurities and is prone to scale, etc. If you have a water purifier, you can connect the original water purification device, just add a float or a solenoid valve
QCan the device automatically add water?
A Automatic water replenishment requires additional billing (including water replenishment device and water purifier)
Knowledge