| pH Measurement Range | -2.000~20.000pH |
| pH resolution | 001/0.01/0.1pH, optional |
| pH measurement Accuracy | ±0.002pH |
| pH calibrating point | 1 to 5 points |
| pH buffering options | USA/NIST/DIN/5 Custom Buffers |
| mV range | -2000.0~2000mV |
| mV resolution | 0.1/1 mV, optional |
| mV measurement Accuracy | ±0.2mV |
| Temperature compensation range | 0~100 ° C/32~ 212 ° F, Automatic |
| Stability condition | Fast/standard/high Accuracy |
| measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10/30/60/300 seconds or off |
| Calibrated expiration reminder | 1 to 99 days or closed |
| High/Low Limit Alarm | optional |
| ORP Measurement Range | ±2000.0mV |
| ORP resolution | 0.1/1 mV, optional |
| ORP measurement Accuracy | ±0.2mV |
| ORP calibrating point | 1 point |
| ORP measurement mode | Relative or absolute mV |
| Stability condition | Fast/standard/high Accuracy |
| measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10/30/60/300 seconds or off |
| Calibrated expiration reminder | 1 to 99 days or closed |
| Ion concentration Measurement Range | 0.001~ 30000 (depending on the range of the ion selective electrode) |
| Ion concentration display resolution | 0.001, 0.01, 0.1, 1, automatic |
| Ion concentration measurement Accuracy | +/- 0.5% F.S. (diion ), +/- 1% F.S. (diion) |
| Ion concentration calibrating point | 2 to 5 points |
| Ion concentration calibrating liquid | 0.001/0.01/0.1/1/10/100/1000/10000 |
| Ion concentration measurement unit | ppm,mg/L,mol/L,mmol/L |
| Ion concentration measurement method | Direct reading, known addition, known reduction, sample addition, sample reduction |
| Ion concentration electrode management | 1 to 3 |
| Ion -mV range | ±2000.0mV |
| Ion-mV display resolution | 0.1/1 mV, optional |
| Ion -mV measurement Accuracy | ±0.2mV |
| Temperature compensation range | 0~100 ° C/32~ 212 ° F, Automatic |
| Stability condition | Fast/standard/high Accuracy |
| measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10/30/60/300 seconds or off |
| Calibrated expiration reminder | 1 to 99 days or closed |
| High/Low Limit Alarm | optional |
| Water hardness Measurement Range (concentration) | 0.05~200mmol/L |
| Water hardness Measurement Range (German degrees) | 0~1122°dH |
| Water hardness Measurement Range (UK degrees) | 0~1404°e |
| Water hardness Measurement Range (French degrees) | 0~2000°fH |
| Water hardness Measurement Range (GPG) | 0~1170gpg |
| Water hardness Measurement Range (CaCO) | 0~20000mg/L |
| Water hardness Measurement Range (CaO) | 0~11220mg/L |