China

TEELEN WLY-01M Microscopic Counting Method-Insoluble Particulate Meter

WLY-01M microscopic counting method-insoluble microparticle meter is suitable for the testing of insoluble microparticles such as various intravenous injections and packaging materials.
Model:
Certificate

Teelen WLY-01M Microscopic Counting Method - Insoluble Particulate MeterSPEC

Teelen WLY-01M Microscopic Counting Method - Insoluble Particulate MeterDetails

Teelen WLY-01M Microscopic Counting Method - Insoluble Particulate MeterPacking list

SKU
NB042278
test range
1 Jie m-600 Jie m
eyepiece
10X
objective lens
5 times, 10 times, 20 times, 40 times, 100 times
High definition digital camera
5 million pixels
Repeatability Error
Less than 5%
Optional
Imported brands Microscope, OLYMPUS, Lycra, Nikon, etc
WLY-01M
Microscopic Counting Method - Insoluble Particulate Meter
WLY-01M microscopic counting method-insoluble microparticle meter is suitable for the testing of insoluble microparticles such as various intravenous injections and packaging materials.
TEELEN WLY-01M Microscopic Counting Method-Insoluble Particulate Meter Picture

Application background

The United States Pharmacopoeia USP788, Chinese Pharmacopoeia CP0903 and other pharmacopeias of various countries have clearly defined regulations on intravenous injections (solution injections, sterile powders for injection, concentrated solutions for injection) and sterile raw materials for intravenous injection, and insoluble particles need to be checked. It is also stipulated that the first method uses the photoresist method, and the second method uses the microscope counting method. When the first method fails to pass the test, the second method - microscopic counting method is used for testing and is the basis for the final judgment.

The Application of the first photoresist method: intravenous injections, including clear and transparent small injections, large infusions, sterile powders, etc.;

Application of the second method of microscopic counting: intravenous injections, including clear and transparent small injections, large infusions, sterile powders, colored injections, large viscosity injections, emulsions, liposomes, suspensions, and injections prone to bubbles , contrast agents, vaccines, trace samples, biological drugs, intraocular injections, etc.

Introduction

 WLY-01 series products are suitable for testing insoluble particles such as various intravenous injections and packaging materials. The main products include microscope host, electric platform, analysis software, computer, etc. The supporting consumables include filter device, blank source membrane, grid filter membrane, raw silver, dust removal brush, drying system, suction filter pump, and dust-free petri dish. wait.

Dellun Optical WLY-01M Microscopic Counting Method-Insoluble Particle Meter Details Figure 1


Implementation standards

United States Pharmacopeia USP787, USP788, USP789;

European Pharmacopoeia EP6.0, EP7.0, EP7.8, EP8.0;

British Pharmacopoeia BP2013, BP2012, 201. , 2009;

Japanese Pharmacopoeia JP16, JP15, JP14;

Chinese Pharmacopoeia Cp0903, etc.

Test process

1) Sample filtration: Place a clean 25mm filter membrane on the appropriate filter, so that all samples pass through the warm membrane.

2) Drying the filter membrane: Place the filtered membrane in a clean petri dish with a dust-free inlay, and use a Dry Bath to select an appropriate temperature for drying.

3) Scanning membrane: The dried filter membrane is placed under the microscope objective and the entire membrane is scanned.

4) Data analysis: Perform data analysis on all scanned film images, and finally get a report.


Applications

As shown in the figure below, the red injection solution is filtered using a filtration device. After filtration, the filter membrane is dried, and then the dried filter membrane is placed on a fully automatic scanning microscope platform, and a 10x objective lens is used to scan the entire filter membrane. The software Analyze the scanned filter membrane, and finally issue a data report according to the test requirements.

Dellun Optical WLY-01M Microscopic Counting Method-Insoluble Particle Meter Details Figure 2

configuration list

serial numbernameunitquantityRemark
1Microscope host (transflective light source)tower1Standard configuration
2Automatic mobile scanning platformset1Standard configuration
3manualshare1Standard configuration
4Certificateshare1Standard configuration
5Random packing listshare1Standard configuration
6Supporting filter deviceset1Standard configuration
7Millipore 25mm blank filter membranebox1Optional
8Flat-headed bratBundle2Standard configuration
9Dry Bathset1Optional
1021CFR Parti 1 softwareset1Optional
11data cableset1Standard configuration
12Dust coverset1Standard configuration
13MicrometerBundle1Standard configuration
145 gm standard particlesbottle1Standard configuration
1510 standard particlesbottle1Standard configuration
1625 standard particlesbottle1Standard configuration
17On-site 3Q verification and documentationshare1Standard configuration
18dust brushBundle1Standard configuration
19lens tissueBook5Standard configuration
20Computer (i5, hard drive 1T, memory 8G)tower1Optional
twenty oneStandard version (including measurement)indivual1Standard configuration


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.