- SKU
- NB042710
- Temperature range
- RT+~400℃
- Measuring method
- Automatic, visual (playback monitoring)
- Experimental method storage Capacity
- 300 kinds
- password hierarchical management
- Level 4
- user management
- 50
- Electronic signature
- Yes.
- data traceability
- Yes.
- Temperature Resolution
- 0.1℃
- Heating rate
- 0.2/0. 5/1/1 5/2/3/4/5 ℃/min
- Error of indication
- ±0.4℃(≤200℃);±0.7℃(>200℃)
- Repeatability
- When the Heating rate is 0.2 ℃/min, when the Heating rate of 0.2 ℃ is 1.0 ℃/min, 0.3 ℃
- linear Heating rate error
- ±10%
- processing power
- 3
- Capillary tubing size
- Outer diameter is 1.4mm; Inner diameter is 1.0mm; Length is 90mm.
- Sample height
- 3mm
- Operating system
- WINDOWS
- Data storage
- 16G
- Display mode
- 8-Inch LCD touch screen
- Calibration method
- 8 point calibrated
- Interface
- USB/keyboard/mouse/universal printer/VGA/Ethernet network interface card/optional wireless network interface card
- Power Supply
- 220V±22V 50Hz±1Hz
- Dimensions
- 390*320*240mm
- Net Weight of instrument
- 13kg
SGW-630
Automatic image grease melting point (slip point) instrument
With high resolution digital camera and image processing analysis, can simultaneously measure 3 samples, support automatic and visual measurement. Built-in Windows, data can be saved, exported and have electronic signature and data traceability functions. Temperature control system uses high accuracy platinum resistor
Features
• High-resolution digital camera, automatic detection through image processing and analysis, with playback function.
• Multiple capillaries can be measured at the same time, and 3 samples can be measured at the same time.
• BUILT-IN WINDOWS OPERATING SYSTEM, SIMPLE, CONVENIENT, INTUITIVE AND CLEAR, YOU CAN CONNECT TO THE PRINTER. The instrument can measure dark samples or opaque samples, with multi-point calibration function, and the test data can be saved, exported and uploaded.
• It has two functions: automatic measurement and manual visual measurement, which is convenient to clearly grasp the continuous change process of the sample, and can verify the accuracy of automatic testing and visual measurement with each other. The temperature control system uses platinum resistance with high linearity as the detection element, which improves the accuracy and reliability of the data.
• SGW-630® complies with the relevant requirements of NCP, GMP, GLP and FDA/21CFR Part 11, including user hierarchical management, electronic signature, password management, network transmission,
Data protection and traceability
Packing list:host X1, manual X1, certificate X1, warranty card X1
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.