China

MODERNER QXD-100 small double-channel qxd Fineness gauge 100 micron pigment Fineness gauge

SE
The MODERNER small double-channel qxd-100 Fineness gauge is made of stainless steel, with a range of 0-100 microns, a Graduation of 5 μm, scale units μm and Hegman. The QXD-100 Fineness gauge is widely used in the determination of particle Fineness such as pigments and impurities in Paints and paint pastes.
Certificate

Moderner QXD-100 (small double-channel) Small double-channel Fineness gaugeSPEC

Moderner QXD-100 (small double-channel) Small double-channel Fineness gaugeDetails

Moderner QXD-100 (small double-channel) Small double-channel Fineness gaugePacking list

SKU
NB004309
Scraper type
double-channel
Number of grooves
2
range
0 ~ 100µm
Scale unit
mm
Scraper material
stainless steel
Scraper size
170*63.5*12.7mm
Groove size
12.7*140mm
Scraper material
stainless steel
Scraper size
70mm
Applicable standard
JJG(化)018-96、GB/T1724
Graduation
5μm
QXD-100 (small double-channel)
Small double-channel Fineness gauge
MODERNER QXD-100 small double-channel qxd Fineness gauge 100 micron pigment Fineness gauge Picture

MODERNER QXD stainless steel Fineness of Grind Gauge is a small double-slot type qxd Fineness Meter, which is made of high-grade stainless steel, and the applicable measuring range is 0~25/50/100 microns. The Fineness of Grind Gauge is widely used in the measurement of the fineness of particles such as pigments and impurities in paints and varnishes. MODERNER is a qxd Fineness Meter designed and manufactured according to the verification regulations of the Ministry of Chemical Industry of the People's Republic of CHINA JJG (chemical) 018-96 "Fineness of Grind Gauge" and its GB/T1724 standard .

 The models of QXD-25/50/100 small double-slot qxd Fineness Meter are QXD-25, QXD-50, QXD-100, and the corresponding measuring ranges are 0~25 microns, 0~50 microns, 0~100 microns .

Steps for usage

1. Before using the qxd Fineness Meter , wash the plate and the bottom with a suitable solvent, and dry it with cotton yarn.

2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.

3. Drop a few drops of sample solution into the deepest part of the groove of the stainless steel Grindometer.

4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.

5. After scraping, immediately (within no more than 5 seconds) pinch the fineness gauge horizontally and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the scale of the particles in the groove and the exposed part with light value, the reading value is the fineness of the measured object.

Precautions for use

(1) Do not scratch the surface of the qxd fineness gauge and the scraper.

(2) Wash and apply vaseline to prevent rust after use.

(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted and then measured.

(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.

real shot

QXD-100 small double groove Fineness Meter material description

QXD-100 small double groove fineness gauge standard

QXD-100 small double groove fineness measurement degree scale

QXD-100 small double groove Fineness Meter quality

Specification list

MODERNER Fineness of Grind Gauge series specification list

Series

SpecificationRangeDivision valueGroove sizeunit
small single slot0-150.7512.7*140μm
0-251.25Hegman/μm
0-502.5
0-1005
0-1505μm
small double slot0-252.5Hegman/μm
0-502.5
0-1005
0-1505μm
wide slot0-251.2525.4*127Hegman/μm
0-502.5
0-1005
large wide groove0-252.550.8*127
0-505
0-1005
Big double slot0-252.525.4*165Hegman/μm/NPIRI
0-505
0-1005
Special double slot0-502μm
0-25010μm


FAQ
QCan this one test the Fineness of the paste?
A Hello, it's OK.
QI want to measure the cleanliness of emulsion paint. Is this Fineness Meter suitable?
A The number of particles in the emulsion paint above the Fineness meter reading is suitable for indicating the cleanliness of the emulsion paint and is therefore appropriate.
QAre all small double-channel Fineness gauges available for detection in the JT/T821.3 standard?
A Not necessarily, but this QXD-100 (small double-channel) small double-channel Fineness gauge can be considered.
QCan the QXD100 double-channel Fineness gauge test slurries around 75 microns?
A Yes, the small double-channel scraper fineness Measurement can scrape the material fineness below 0~ 100μm.
Standard