TAISITE GP-30BE drying/foster dual-use box, program-controlled type 30L

Adopt double air duct forced convection mode, adopt liquid crystal dual row PID temperature control, fluctuation foster +/- 0.5 ℃, drying +/- 1 ℃, set drying, baking, wax, heat treatment and bacterial foster in one.
Certificate

TaiSiTe GP-30BE (with program mode) Drying/fostering dual-use boxSPEC

TaiSiTe GP-30BE (with program mode) Drying/fostering dual-use boxDetails

TaiSiTe GP-30BE (with program mode) Drying/fostering dual-use boxPacking list

SKU
NB043106
Temperature range
Foster: RT + 5~ 80 ℃; drying: 80~250 ℃
Temperature Fluctuation
A.±0.5℃;B.±1℃
Temperature Resolution
0.1℃
Temperature Uniformity
Foster +/- 1.0 ℃; drying +/- 2.5%
Volume
30L
Interior size
310*310*310mm
Chamber material
stainless steel plate
Shelf (std.)
2pcs
Shelves (max)
6pcs
Load per shelf
15kg
Timer
0~9999Min (with Timer waiting)
Power
AC220V/3.6A 50/60Hz
Input Power
Foster: 0.3Kw; drying: 0.8Kw
Dimensions
445*440*690mm
Net Weight
32kg
Enclosure Material
Cold rolled steel plate, surface resistance painting
Thermal insulation material
aluminum silicate fiber
Heating mode
Stainless steel heating tube
Exhaust port
Inner diameter 28mm * 1, top
thermostat
Liquid crystal dual row PID
Temperature setting
Tap the four-button settings
Temperature representation
Measuring temperature display: liquid crystal upper display; setting temperature display: liquid crystal lower display
Run function
Fixed value operation, Timer operation, automatic stop
Program Mode
Standard, single-stage temperature control and program temperature control can be converted to each other, 50 experimental programs can be stored, each program can be set to 50 steps, and each step can be set to 0-6000 minutes adjustable
Additional features
Deviation correction, menu button lock, power outage compensation, power outage memory, speed regulating fan, overlift preventer
Temperature sensor
pt100
Packing size
560*560*830mm
Shelf spacing
35mm
Gross Weight
37Kg
Safety Devices
Overlift alarm, overlift preventer
Convection mode
Double duct forced convection
Shelf (std.)
2pcs
Shelf (std.)
4pcs
GP-30BE (with program mode)
Drying/fostering dual-use box
Adopt double air duct forced convection mode, adopt liquid crystal dual row PID temperature control, fluctuation foster +/- 0.5 ℃, drying +/- 1 ℃, set drying, baking, wax, heat treatment and bacterial foster in one.
TAISITE GP-30BE drying/foster dual-use box, program-controlled type 30L Picture

Benefits:

  • Drying, baking, wax melting, heat treatment and bacterial culture are all in one box

  • High precision, high efficiency, safety, wide range.

  • Convenient operation, fixed value operation, timed operation, automatic stop. PID thermostat, accurate temperature control.

  • Dedicated function keys enable temperature setting.

  • Auxiliary menu, to achieve over-rise alarm, deviation correction, menu locking.

  • Vertical double air duct air jacket, turbine centrifugal forced air supply, more uniform temperature.

  • Speed-controlled fans enable the use of lightweight, fine, powdery samples.

  • The forced fan heat dissipation and air intake structure makes the maximum working temperature of the fan < 50°C, and the operation is long-lasting for a long time.

  • LCD multi-data full-screen operation display, power failure memory, power failure compensation

  • Overlift preventer

Detail design advantages

Figure 1: Heating curve: time unit: minutes, temperature unit: °C

Figure 2,Multi-functionalAble to control the panel

 Detail Figure 1 of the Tester GP-30BE Drying/Incubation Chamber Details of the Tester GP-30BE Drying/Incubation ChamberFigure 2

                                                                Figure 1 Figure 2

Parameter comparison

ModelheaterContent volumeNumber of partition layers
GP-30B/BEStainless steel heating tubes30L6 floors
GP-45B/BEStainless steel heating tubes45L7 floors
GP-65B/BEStainless steel heating tubes65L9 floors
GP-125B/BEStainless steel heating tubes125L13 floors
GP-230B/BENichrome heating wire230L17 floors
Other parameters
mannerDual air ducts force convection
Operating temperature rangeIncubation RT+5~80°C and drying 80~250°C
Temperature resolution0.1℃
Temperature fluctuationsIncubation ± 0.5 °C dry ± 1 °C
Temperature distribution accuracyIncubation± 1.0 °C dry ± 2.5%
Built-inStainless steel plate
ExteriorCold-rolled steel plate, surface resistant coating
Insulating materialsAluminum silicate fiber
Exhaust outletsInner diameter 28mm*1, top
Temperature control methodType B: Digital tube double-row PID;BE type: LCD double-row PID
Temperature setting methodTap the four buttons to set it
Temperature representationType B: Measured temperature display: 4-digit digital upper display, set temperature display: 4-digit digital lower display
BE type: Measured temperature display: liquid crystal upper display, set temperature display: liquid crystal lower display
timer0~9999 minutes (with timed waiting function)
Run the functionFixed-value operation, timed operation, automatic stop
Program modeStandard, single-stage temperature control and program temperature control can be converted to each other, 50 experimental programs can be stored, each program can be set to 50 steps, each step can be set 0-6000 minutes can be adjusted
Additional featuresDeviation correction, menu button locking, power failure compensation, power failure memory (BE type: Overlift preventer)
sensorpt100
Safety devicesOverlift Alarm (BE Type Overlift Arrester)
clapboard2 pcs
Partition shelves4 pcs
Configurations can be added(GPBE type) partition, RS485 interface, printer, Recorder, external communication, remote control, program thermometer, wireless SMS alarm, U disk data storage


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.