Rapid, safe and reliable sterilization.
Convenient operation, fixed value operation, timed operation, automatic stop.
Dedicated function keys enable temperature setting.
Auxiliary menu, realize over-rise alarm, deviation correction, menu locking.
Vertical double air duct air jacket, turbine centrifugal forced air supply, more uniform temperature.
Speed-controlled fans enable the use of lightweight, fine, powdery samples.
The forced fan heat dissipation and air intake structure makes the maximum working temperature of the fan < 50°C, and the operation is long-lasting for a long time.
Figure 1LCD multi-data control panel:Multi-data full-screen operation, power failure memory, power failure compensation (BE model).
Figure 2, multi-functional safety lock: safe and secure.
Figure 3,Furnace temperatureDegree Rise Chart:The temperature rise curve is professional because it is accurate.
Figure 4,partitionThermal Safety Door:It is not hot to stand around the instrument at work.

Fig.1 Fig.2 Fig.3 Fig.4
| Model | Rated power | Content volume | Number of partition layers |
| GX30B/GX30BE | 0.8KW | 30L | 6 floors |
| GX45B/GX45BE | 1.2KW | 45L | 7 floors |
| GX65B/GX65BE | 1.6KW | 65L | 9 floors |
| GX125B/GX125BE | 2.3KW | 125L | 13 floors |
| GX230B/GX230BE | 3KW | 230L | 17 floors |
| Other parameters | |||
| manner | Dual air ducts force convection | ||
| Operating temperature range | RT+10~300℃ | ||
| Temperature resolution | 0.1℃ | ||
| Temperature fluctuations | ±1℃ | ||
| Temperature distribution accuracy | ±2.5% | ||
| Built-in | Stainless steel plate | ||
| Exterior | Cold-rolled steel plate, surface resistance * quality coating | ||
| Insulating materials | Aluminum silicate fiber | ||
| Temperature control method | Type B: Digital tube double-row PID;BE type: LCD double-row PID | ||
| Temperature setting method | Tap the four buttons to set it | ||
| Temperature representation | Type B: Measured temperature display: 4-digit digital upper display, set temperature display: 4-digit digital lower display | ||
| BE type: Measured temperature display: liquid crystal upper display, set temperature display: liquid crystal lower display | |||
| timer | 0~9999 minutes (with timed waiting function) | ||
| Run the function | Fixed-value operation, timed operation, automatic stop | ||
| Program mode | Standard, single-stage temperature control and program temperature control can be converted to each other, 50 experimental programs can be stored, each program can be set to 50 steps, each step can be set 0-6000 minutes can be adjusted | ||
| sensor | pt100 | ||
| Safety devices | Overlift Alarm (BE Type Overlift Arrester) | ||
| clapboard | 2 pcs | ||
| Partition shelves | 4 pcs | ||
| Configurable (GXBE type) | Partition, RS485 interface, printer, Recorder, external communication, remote control, program thermometer, wireless SMS alarm, U disk data storage | ||
| power supply | AC 220V 50/60Hz | ||