China

TRUIT TR 1002/5 Ford Viscosity Cup outflow aperture φ5.20mm

SE
In line with ASTM standards, the outflow aperture is φ5.20mm, the measurement viscosity range is 200~1200cst, the filter is made of high-quality stainless steel, and the volume is 100ml.
$125.00/piece
PromotionLoading...
Coupon
Model:
Certificate

TRUIT TR 1002 / 5 Ford Viscosity CupSPEC

TRUIT TR 1002 / 5 Ford Viscosity CupDetails

TRUIT TR 1002 / 5 Ford Viscosity CupPacking list

SKU
NB043163
outflow time
20~105sec
Viscosity range
200~1200cst
Capacity
100ml
Nozzle material
High quality stainless steel
Main material
High quality aluminum alloy (anodic oxidation)
Cup size
Top outer diameter Φ82mm, cup body outer diameter Φ56mm
TR 1002 / 5
Ford Viscosity Cup
In line with ASTM standards, the outflow aperture is φ5.20mm, the measurement viscosity range is 200~1200cst, the filter is made of high-quality stainless steel, and the volume is 100ml.
TRUIT TR 1002/5 Ford Viscosity Cup outflow aperture φ5.20mm Picture

Introduction

Ford (FORD) Viscosity Cup is a commonly used flow time cup for measuring the viscosity of liquids. It is designed according to the Ford (FORD) standard for evaluating the viscosity characteristics of materials such as paints, varnishes and coatings. There is a small hole at the bottom of it, and the cup body is made of high-quality aluminum with a capacity of about 100ml. The viscosity of the material can be evaluated by measuring the time required for a certain volume of sample in the cup to flow out of the small hole at the bottom, which can be used A specific formula converts the flow time to a viscosity value.

TR 1002 series Ford cups are made of high-quality aluminum alloy, with a capacity of 100ml and a variety of aperture specifications to choose from. They are designed in accordance with ASTM D1200, ASTM D 333, and ASTM D 365 standards. Widely used in the paint, paint and coating industry, especially in the field of automobile manufacturing and restoration.

Features

  • Main material: high-quality aluminum alloy (anodized)

  • Nozzle material: high quality stainless steel

  • Capacity: 100ml

  • Cup body size: top outer diameter φ82mm, cup body outer diameter φ56mm

Series

order numberOutflow aperture (mm)Measuring range (cst)Outflow time (sec)
TR 1002/1φ1.9010~3555~100
TR 1002/2φ2.5325~12040~100
TR 1002/3φ3.4049~22025~105
TR 1002/4φ4.1270~37020~105
TR 1002/5φ5.20200~120020~105
FAQ
QWhy is the viscosity value provided by the viscosity cup a relative estimate?
A The viscosity data provided by viscosity cups are relative estimates because they are affected by liquid properties and environmental conditions and do not provide the same Accuracy as precision laboratory instruments.
Knowledge
Standard