Laboratory Electronic Balance Tianma TD15K-0.1 Range up to 15kg Minimum reading 0.1g

SE
0~15Kg, Readability 0.1g, nonlinear error +/- 0.3g, Repeatability Error +/- 0.3g, test weight 10kg, external calibrated, trapezoidal pan 300 * 330 * 240mm
$215.00/set
PromotionLoading...
Coupon
Model:
Certificate

TianMa TD15K-0.1 TD Series Electronic BalanceSPEC

TianMa TD15K-0.1 TD Series Electronic BalanceDetails

TianMa TD15K-0.1 TD Series Electronic BalancePacking list

SKU
NB004325
Weighing range
0~15kg
readability Accuracy
0.1g
Nonlinear error
±0.3g
Repeatability Error
±0.3g
Calibrated Weight
10kg
Calibrating function
Externally calibrated
Settling time
≤5s
Operating Conditions
5~40°C 50%RH~60%RH
Pan size
Trapezoidal pan 300 * 330 * 240mm
Power
Adapter, Input:~ 220V 50/60Hz Output: DC7.5V-300mA
Instrument net Weight
6000g
Dimensions
370*380*130mm
Packaging Dimensions
450*425*210mm
TD15K-0.1
TD Series Electronic Balance
0~15Kg, Readability 0.1g, nonlinear error +/- 0.3g, Repeatability Error +/- 0.3g, test weight 10kg, external calibrated, trapezoidal pan 300 * 330 * 240mm
Laboratory Electronic Balance Tianma TD15K-0.1 Range up to 15kg Minimum reading 0.1g Picture

An overview of laboratory electronic balances

Tianma LABOratory Electronic Balance TD15K-0.1 has a maximum capacity of 15kg and a minimum reading of 0.1g. It is a laboratory Electronic Analytical Balance with an ultra-large thickened stainless steel trapezoidal weighing pan. The laboratory electronic balance TD15K-0.1 is equipped with a calibration weight of 10kg, and the Repeatability Error is ±0.3g.

LABOratory Balance Features

1. The weighing accuracy is 0.1g.

2. International unit conversion function .

3. AC and DC dual-purpose function, the balance is equipped with a rechargeable battery.

4. Large and thick stainless steel trapezoidal weighing pan.

5. Equipped with RS232 serial port, which can be used for computer and printer connection.

6. It has the functions of tare, weighing automatic calibration, automatic zero clearing, zero automatic tracking and fault display .

7. With counting function (point function), it can be conveniently used as a counting balance.

LABOratory electronic balance display diagram


Tianma LABOratory Electronic Balance TD15K-0.1 Appearance


FAQ
QI've had a TD15K-0.1 Balance for years, but now the numbers keep jumping when I turn it on
A Turn off the machine, take down the pan, do a good job of hygiene, turn the Balance upside down and knock it, and something is in it.
QDoes Balance meet the specifications of GB/T26497?
A Model TD15K-0.1 Balance Compliant
Standard