China

Kenton KH-75AS digital electric air blowing dryer 250 ℃/225L with independent temperature limiter

SE
Stainless steel liner, intelligent PID control digital display, with timing and blast function, liner size 750 × 600 × 500mm, Shelf spacing, quantity adjustable, with independent temperature control.
$744.00/set
PromotionLoading...
Coupon
Certificate

Kenton KH-75AS + independent temperature limiter Digital electric air blowing dryerSPEC

Kenton KH-75AS + independent temperature limiter Digital electric air blowing dryerDetails

Kenton KH-75AS + independent temperature limiter Digital electric air blowing dryerPacking list

SKU
NB043561
Temperature range
RT+5~250
Temperature Fluctuation
±1%
Accuracy
±0.5℃
Volume
225L
Interior size
750*600*500mm
Chamber material
stainless steel
Enclosure Material
Cold rolled steel plate surface electrostatic spraying
Timer
0~999min
Viewing Window
Yes.
Power
220V
Input Power
2.5Kw
Dimensions
980*965*770mm
KH-75AS + independent temperature limiter
Digital electric air blowing dryer
Stainless steel liner, intelligent PID control digital display, with timing and blast function, liner size 750 × 600 × 500mm, Shelf spacing, quantity adjustable, with independent temperature control.
Kenton KH-75AS digital electric air blowing dryer 250 ℃/225L with independent temperature limiter Picture


Kangheng KH-75AS+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 1

Kangheng KH-75AS+ Independent Temperature Limiter Digital Display Electric Forced Air Drying Oven Details Figure 2

Kangheng KH-75AS+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 3

Kangheng KH-75AS+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 4

Kangheng KH-75AS+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 5

Recommendations

Routine experiments and tests are recommended, cost-effective. For more expensive samples, it is recommended to install an independent temperature limit controller.

Application

It is used for drying, heat treatment, and heating in various medical and health, medicine, biology, agriculture, scientific research and other departments, but it is not suitable for volatile, flammable, explosive and other items, so as not to cause explosion.

warn! It is strictly forbidden to put flammable, explosive and volatile items into the box for heating and drying. For high-value materials, it is better to install an independent temperature limiter to set the upper limit of the maximum temperature. Double insurance ensures that the materials will not fail due to the electronic components of the box. Excessive heating can lead to damage.

Structural features

1. Using microcomputer intelligent PID control technology, the system has temperature control, timing, and over-temperature alarm functions;

2. The external hot air circulation system is composed of low-noise fans and air ducts. Reasonable air duct and circulation system to stabilize the temperature in the working room;

3. The shell is made of good cold-rolled steel plate treated by electrostatic spraying, the overall design is beautiful and novel, and it has a large Viewing Angle observation window;

4. The liner is divided into mirror stainless steel and galvanized steel, and the semi-curved corners are easy to clean;

5. The distance between shelves and the number of shelves in the studio can be adjusted to facilitate access to samples of different specifications;

6. Use high-temperature resistant silica gel as the sealing door, and high-temperature heating tube as the heating element to ensure safety and longer service life;

7. Ergonomic buckle handle, easy to operate, and ensure tightness.

Optional :

1. Independent temperature limit controller;

2. Intelligent program temperature controller.

Kangheng KH-75AS+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 6

Models

Digital display electric Forced Air Drying Oven (galvanized liner, with timer)

model

Studio size (mm)

Power (KW)

KH-25A

250×250×265

0.5

KH-30A

250×250×265

0.5

KH-35A

350×350×350

1

KH-45A

450×450×350

1.2

KH-55A

550×550×450

1.6

KH-75A

750×600×500

2.5

Digital display electric Forced Air Drying Oven (stainless steel liner, with timing)

KH-25AS

250×250×265

0.5

KH-30AS

250×250×265

0.5

KH-35AS

350×350×350

1

KH-45AS

450×450×350

1.2

KH-55AS

550×550×450

1.6

KH-75AS

750×600×500

2.5

All stainless steel digital display Forced Air Drying Oven (galvanized liner, with timer)

KH-35T

350×350×350

1

KH-45T

450×450×350

1.2

KH-55T

550×550×450

1.6

KH-75T            

750×600×500

2.5

FAQ
QOur laboratory needs a drying oven for routine experiments, and the sample value is average. Do you have any recommendations?
A Recommended KH-75AS digital display electric air blowing dryer, this cost-effective, using microcomputer PID control technology, temperature accuracy +/- 0.5 ℃, with timing and over-temperature alarm function, suitable for routine experiments.
QWe mainly use it to dry agricultural scientific research samples. We need large capacity and stable temperature. Which one is suitable?
A It is recommended to choose KH-75AS, Inner chamber dimensions 750 × 600 × 500mm, volume 225L, air-thermal circulation system can keep the temperature stable at +/- 1% Fluctuation, stainless steel liner is easy to clean, suitable for drying of agricultural scientific research samples.
QSome of our valuable samples need to be heated. How can we ensure safety?
A It is recommended that the KH-75AS be equipped with an independent temperature limiter, which can set the maximum temperature limit and form a double insurance with the main control system to prevent high temperature damage to valuable samples due to electronic component failure. This is the best solution to protect high-value materials.
Standard