China

MODERNER QXD-100 single-channe Fineness meter, corrosion-resistant stainless steel 0~100μm range

SE
Single-channe, range 0~100μm, scale unit μm, scraper material stainless steel, groove size 12.7 * 140mm, scraper material stainless steel, scraper size 70mm, Graduation 5μm.
Certificate

Moderner QXD-100 (single-channe) Single-channe Fineness gaugeSPEC

Moderner QXD-100 (single-channe) Single-channe Fineness gaugeDetails

Moderner QXD-100 (single-channe) Single-channe Fineness gaugePacking list

SKU
NB004391
Scraper type
Single-channe
Number of grooves
1
range
0 ~ 100µm
Scale unit
mm
Scraper material
stainless steel
Scraper size
170*50*12mm
Groove size
12.7*140mm
Scraper material
stainless steel
Scraper size
70mm
Graduation
5μm
QXD-100 (single-channe)
Single-channe Fineness gauge
Single-channe, range 0~100μm, scale unit μm, scraper material stainless steel, groove size 12.7 * 140mm, scraper material stainless steel, scraper size 70mm, Graduation 5μm.
MODERNER QXD-100 single-channe Fineness meter, corrosion-resistant stainless steel 0~100μm range Picture

MODERNER QXD-100 single-slot Fineness Meter is a single-slot Fineness of Grind Gauge made of anti-corrosion stainless steel. The fineness range of QXD-100 is 0~100 μm, and the division value is 5 microns. QXD-100 single-slot Fineness Meter has two scale units of Hegman and micron, and is designed and manufactured according to JJG (Chemical) 018-96 "Fineness of Grind Gauge" and its GB/T1724 standard.

Application

Applications include paints, plastics, pigments, printing inks, paper, ceramics, medicine, food, etc. 

real shot

QXD-100 single groove Fineness Meter standard description

QXD-100 single groove Fineness Meter material description

Description of QXD-100 single groove fineness measuring range

operation method

1. Before using the QXD-100 single-slot Fineness Meter, wash the board and bottom with a suitable solvent, and dry it with cotton yarn.

2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.

3. Drop a few drops of sample solution into the deepest part of the groove of the QXD-100 single groove Fineness Meter .

4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.

5. After scraping, immediately pinch the QXD single-groove Fineness of Grind Gauge horizontally (within 5 seconds) and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the particle uniformity in the groove with light. and the scale value at the exposed place, the reading value is the fineness of the measured object.

Maintenance

(1) Clean it immediately after use and apply vaseline to prevent the fineness gauge from rusting.

(2) Do not scratch the surface of the QXD single-slot Grindometer and the scraper.

(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted first, and then measured with the QXD single-slot Fineness of Grind Gauge .

(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.

Specification list

MODERNER Fineness of Grind Gauge series specification list

Series

SpecificationRangeDivision valueGroove sizeunit
small single slot0-150.7512.7*140μm
0-251.25Hegman/μm
0-502.5
0-1005
0-1505μm
small double slot0-252.5Hegman/μm
0-502.5
0-1005
0-1505μm
wide slot0-251.2525.4*127Hegman/μm
0-502.5
0-1005
large wide groove0-252.550.8*127
0-505
0-1005
Big double slot0-252.525.4*165Hegman/μm/NPIRI
0-505
0-1005
Special double slot0-502μm
0-25010μm


FAQ
QI want an instrument that can test the particle size of inks, 100 microns, which one is suitable?
A You can use QXD 100 micron Fineness of Ground Gauge.
QIf you buy a Fineness meter, what standard should you buy it according to? Is it according to the finest particle size in my Coating?
A Hello, the Fineness gauge finally tests the maximum Fineness. The principle of the Fineness gauge determines that scraping it down in this way will only leave the large particles of Fineness in the thinnest place, and it will not be scraped later, so it has nothing to do with how fine it is, but how thick it is. The purpose of dispersing the ground is to make it thin, and using the Fineness gauge is to test the largest particles.
QIs this modern QXD scraper Fineness meter made of stainless steel?
A Hello, yes, wear-resistant stainless steel is used.
Q100μm one path, mainly used in the measurement of lithium battery slurry Fineness, this can be tested?
A Hello, it's OK.
QI want to measure the cleanliness of emulsion paint. Is this Fineness Meter suitable?
A The number of particles in the emulsion paint above the Fineness meter reading is suitable for indicating the cleanliness of the emulsion paint and is therefore appropriate.
QWhat specifications of Fineness gauge do primers generally use?
A Fineness requirements for primers are generally not higher than 50μm/60μm, and a Fineness gauge with a range of 0 to 100 can be used, either single-channe or double-channel.
QIs this single-channe Fineness gauge JT/T821.2 compliant?
A The single-channe Fineness gauge is suitable for JT/T821.2, please consult customer service for detailed application definition
QWhat is the accuracy of the modern one path 100 micron Paint Fineness Meter?
A Hello, the scale interval of the QXD-100 Fineness meter is 5 microns.
QCan the QXD100 single-channe Fineness gauge detect coatings closer to 75 microns?
A In line with the single-channe scraper fineness Measurement process can scrape material fineness below 0~ 100μm.
Standard